Tenders Are Invited For Implementation Of Smr In Connection With The Implementation Of Objects Under Procedure Bg16ffpr003-4.001 Support For Sustainable Energy Renovation Of Multi-Family Residential Buildings, Including Addressing Energy Poverty For Object: Implementation Of Energy Efficiency Measures In A Multi-Family Residential Building On Knyaz Al Blvd. Batenberg No. 10, Stara Zagora
Tenders Are Invited For Implementation Of Smr In Connection With The Implementation Of Objects Under Procedure Bg16ffpr003-4.001 Support For Sustainable Energy Renovation Of Multi-Family Residential Buildings, Including Addressing Energy Poverty For Object: Implementation Of Energy Efficiency Measures In A Multi-Family Residential Building On Knyaz Al Blvd. Batenberg No. 10, Stara Zagora
Implementation Of Smr In Connection With The Implementation Of Objects Under Procedure Bg16ffpr003-4.001 Support For Sustainable Energy Renovation Of Multi-Family Residential Buildings, Including Addressing Energy Poverty For Object: Implementation Of Energy Efficiency Measures In A Multi-Family Residential Building On Knyaz Al Blvd. Batenberg No. 10, Stara Zagora Category Of Construction: Fourth Category, In The Sense Of Art. 137 Of Zut And Ordinance No. 1 On The Nomenclature Of Construction Types. The Public Order Envisages The Implementation Of The Following Measures: Laying Thermal Insulation Of Facade Walls With Eps, With A Thickness Of 15 Cm And A Coefficient Of Thermal Conductivity Λ ≤ 0.035 W/Mk. In The Area Of The Heated Basement, Xps With A Thickness Of 15 Cm And A Coefficient Of Thermal Conductivity Λ ≤ 0.035 W/M. Delivery And Installation Of New Pvc Five-Chamber Double-Glazed Windows With One High-Energy Glass, 4-Season, Heat Transfer Coefficient Uw=1.10 W/Mk In Residential Floors. Replacement Of Window Frames In Commercial Establishments With Aluminum Window Frames With A Heat Transfer Coefficient ≤ 1.70 W/M2k. Thermal Insulation Of A Flat Roof Type 1 With An Air Layer >0.30 Cm. The Measure After Reconstruction Of The Roof Plate Includes Laying Thermal Insulation And Waterproofing On The Roof Plate With Mineral Wool 15 Cm, Coefficient Of Thermal Conductivity Λ ≤ 0.035 W/M2k. Thermal Insulation Of A Flat Roof Type 2 Without An Air Layer. The Measure Includes Laying Thermal Insulation And Waterproofing On The Ceiling Slab Above The Heated Volume With Xps 10Cm Thermal Conductivity Coefficient Λ ≤ 0.035 W/M2k. Thermal Insulation Of Bay Windows Before Laying Topological Insulation System With Eps, Δ= 15 Cm And With Coef. Of Thermal Conductivity Λ≤0.035W/Mk. It Is Planned To Replace The Existing Old Lighting Fixtures With New Energy-Saving Lighting Fixtures, In The Common Areas With Motion Sensors. Other Activities Provided For In The Project Documentation.
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.