Request For Quotation Purchase Of Electricity Goods

Tender Detail

112092885
16844344
Self-Funded
Request For Quotation Purchase Of Electricity Goods
NCB
Central Asia
Commonwealth of Independent States, CIS
23-04-2026

Work Detail

Type: Three-Phase; Number Of Phases: 3; Rated Voltage: 220-380 V; Rated Current: 10 A; Maximum Current: 100 A; Accuracy Class: 1-2; Number Of Tariffs: 4 (Multi-Tariff); Type Of Current: Ac (Alternating); Measurement Method: Direct Connection; Type Of Reading Device: Lcd (Liquid Crystal Indicator); Body Material: Polycarbonate; Mounting Method: On A Plate; Number Of Din Modules: 8; Degree Of Protection: Ip51; Availability Of Communication Interfaces: Rs485 / Irda; Operating Temperature Range: From -40°C To +55°C; Climatic Version: U3, Turi: Our Phases, Bir Tariffs; Kerneu Ratings: 3 × 230/400 V; Current Ratings: 10 A; Current: 100 A; Daldik Sonyby: 2; Tariffer Sana: 1; Tutynylatyn Kuat: Kerneu Boyynsha (Belsendi/Tolyk) - 1.0/7.5 W/Va Artyk Emes, Current Tіzbegi Boyynsha - 0.1 V· A Artyk Emes; Zhumysny Temperature Ranges: -40-Tan +55 °C Valid; Body Materials: Polycarbonate; Installation: Plate; Din Module Number: 8; Rating: Ip51; Connections With Interface: Rs485/Irda; Climate Control: U3;, Type: Three-Phase; Number Of Phases: 3; Rated Voltage: 220-380 V; Rated Current: 10 A; Maximum Current: 100 A; Accuracy Class: 1-2; Number Of Tariffs: 4 (Multi-Tariff); Type Of Current: Ac (Alternating); Measurement Method: Direct Connection; Type Of Reading Device: Lcd (Liquid Crystal Indicator); Body Material: Polycarbonate; Mounting Method: On A Plate; Number Of Din Modules: 8; Degree Of Protection: Ip51; Availability Of Communication Interfaces: Rs485 / Irda; Operating Temperature Range: From -40°C To +55°C; Climatic Version: U3;, Type: Three-Phase; Number Of Phases: 3; Rated Voltage: 220-380 V; Rated Current: 10 A; Maximum Current: 100 A; Accuracy Class: 1-2; Number Of Tariffs: 4 (Multi-Tariff); Type Of Current: Ac (Alternating); Measurement Method: Direct Connection; Type Of Reading Device: Lcd (Liquid Crystal Indicator); Body Material: Polycarbonate; Mounting Method: On A Plate; Number Of Din Modules: 8; Degree Of Protection: Ip51; Availability Of Communication Interfaces: Rs485 / Irda; Operating Temperature Range: From -40°C To +55°C; Climatic Version: U3;, Number Of Modules: 6; Number Of Rows: 1; Material: Impact-Resistant Polystyrene; Body: Plastic; Installation Type: Overhead (Mounted); Degree Of Protection: Ip65; Color: Gray With Transparent Door., Type: Three-Phase; Number Of Phases: 3; Rated Voltage: 220-380 V; Rated Current: 10 A; Maximum Current: 100 A; Accuracy Class: 1-2; Number Of Tariffs: 4 (Multi-Tariff); Type Of Current: Ac (Alternating); Measurement Method: Direct Connection; Type Of Reading Device: Lcd (Liquid Crystal Indicator); Body Material: Polycarbonate; Mounting Method: On A Plate; Number Of Din Modules: 8; Degree Of Protection: Ip51; Availability Of Communication Interfaces: Rs485 / Irda; Operating Temperature Range: From -40°C To +55°C; Climatic Version: U3;, Core: Aluminum, Stranded; Number Of Cores: 4; Core Shape: Round; Cross-Section: 10 Mm²; Insulation: Pvc Compound; Twisting: The Cores Are Twisted Into A Core; Shell: Pvc Plastic; Rated Voltage: 0.66 Kv; Frequency: 50 Hz; Operating Temperature: From -50 To +50 °C; Minimum Installation Temperature: -15 °C (Without Heating); Minimum Bending Radius: 7.5 Cable Diameters; Flammability: Does Not Propagate Combustion When Laid Alone; Flexibility: Flexible (Stranded Core)., Rated Voltage: Not Less Than 0.66 Kv (660 V); Nominal Frequency: 50 Hz; Rated Primary Current: 100 A; Rated Secondary Current: 5 A; Transformation Ratio: 100/5; Accuracy Class: 0.5; Rated Secondary Load: Not Less Than 10 Va; Phase Type: Single-Phase; Installation Version: Internal (In Enclosed Spaces Or Protective Panels); Climatic Version: U3 (Operation At Temperatures From -45°C To +40°C And Humidity Up To 98%); Body: Made Of Low-Flammability, Self-Extinguishing Plastic; Protection Against Theft: Mandatory Presence Of A Protective Transparent Cover On The Terminals Of The Secondary Terminals With Holes Intended For Sealing; Insulation: Compliance With Heat Resistance Class Not Lower Than A.; Purpose: Intended For Transmitting A Signal Of Measuring Information To Electrical Energy Metering Devices In Alternating Current Networks; Documentation: Product Passport (Original) With A Mandatory Mark On Passing The Initial Verification Of The Manufacturer; Mounting Kit: A Set Of Fastenings For Installation On A Mounting Panel;, Number Of Modules: 6; Number Of Rows: 1; Material: Impact-Resistant Polystyrene; Body: Plastic; Installation Type: Overhead (Mounted); Degree Of Protection: Ip65; Color: Gray With Transparent Door., Core: Aluminum, Stranded; Number Of Cores: 4; Core Shape: Round; Cross-Section: 10 Mm²; Insulation: Pvc Compound; Twisting: The Cores Are Twisted Into A Core; Shell: Pvc Plastic; Rated Voltage: 0.66 Kv; Frequency: 50 Hz; Operating Temperature: From -50 To +50 °C; Minimum Installation Temperature: -15 °C (Without Heating); Minimum Bending Radius: 7.5 Cable Diameters; Flammability: Does Not Propagate Combustion When Laid Alone; Flexibility: Flexible (Stranded Core)., Type: Three-Phase; Rated Voltage: 220–380 V; Rated Current: 5 A; Maximum Current: 60 A; Connection Type: Direct Connection; Accuracy Class: 1; Tariffs: Multi-Tariff (Up To 4 Tariffs); Indication Type: Lcd (Liquid Crystal Display); Installation Method: Universal; Space Required: 8 Din Modules; Body Material: Polycarbonate; Degree Of Protection: Ip51; Operating Temperature Range: From -40 To +55 °C; Climatic Version: U3 (For Use In Enclosed Spaces With Natural Ventilation);, Rated Current: 63.0 A; Number Of Poles: 3; Response Characteristic (Current Curve): C; Rated Operating Voltage: 400 V; Voltage Type: Alternating/Direct (Ac/Dc); Frequency: 50 Hz; Rated Breaking Capacity (En 60898): 4.5 Ka; Rated Impulse Withstand Voltage: 4 Kv; Release Type: Thermal And Electromagnetic; Connection Type: Screw Connection; Max. Cross-Section Of Incoming Cable: 25 Mm²; Installation Depth (Niches): 73.6 Mm; Width By Number Of Modules: 3; Degree Of Protection: Ip20; Response Time In The Short Circuit Zone (Tm): 0.1 S; Current Limiting Class: 3; Climatic Version: Uhl4; Energy Loss: 39.0 W; Suitable For Safety Switch Engine: Yes; Additional Equipment Possible: Yes, Type: Three-Phase; Number Of Tariffs: 4 (Multi-Tariff); Accuracy Class: 0.5; Type Of Current: Ac (Alternating); Rated Voltage: 220-380 V; Rated Current: 5 A; Maximum Current: 7.5 A; Type Of Reading Device: Lcd (Liquid Crystal Indicator); Body Material: Polycarbonate; Communication Interfaces: Rs485 / Irda (Infrared Port); Mounting Method: On A Plate; Number Of Din Modules: 8; Degree Of Protection: Ip51; Operating Temperature Range: From -40°C To +55°C; Climatic Version: U3; Measurement Method: Via Transformer, Metal Cabinet With Mounting Panel Shchmp-3 Ip 54 (650X500x220) Ekt 50*65 Cm, Rated Current: 63.0 A; Number Of Poles: 3; Response Characteristic (Current Curve): C; Rated Operating Voltage: 400 V; Voltage Type: Alternating/Direct (Ac/Dc); Frequency: 50 Hz; Rated Breaking Capacity (En 60898): 4.5 Ka; Rated Impulse Withstand Voltage: 4 Kv; Release Type: Thermal And Electromagnetic; Connection Type: Screw Connection; Max. Cross-Section Of Incoming Cable: 25 Mm²; Installation Depth (Niches): 73.6 Mm; Width By Number Of Modules: 3; Degree Of Protection: Ip20; Response Time In The Short Circuit Zone (Tm): 0.1 S; Current Limiting Class: 3; Climatic Version: Uhl4; Energy Loss: 39.0 W; Suitable For Safety Switch Engine: Yes; Additional Equipment Possible: Yes, Type: Three-Phase; Rated Voltage: 220–380 V; Rated Current: 5 A; Maximum Current: 60 A; Connection Type: Direct Connection; Accuracy Class: 1; Tariffs: Multi-Tariff (Up To 4 Tariffs); Indication Type: Lcd (Liquid Crystal Display); Installation Method: Universal; Space Required: 8 Din Modules; Body Material: Polycarbonate; Degree Of Protection: Ip51; Operating Temperature Range: From -40 To +55 °C; Climatic Version: U3 (For Use In Enclosed Spaces With Natural Ventilation);, Core: Aluminum, Stranded; Number Of Cores: 4; Core Shape: Round; Cross-Section: 10 Mm²; Insulation: Pvc Compound; Twisting: The Cores Are Twisted Into A Core; Shell: Pvc Plastic; Rated Voltage: 0.66 Kv; Frequency: 50 Hz; Operating Temperature: From -50 To +50 °C; Minimum Installation Temperature: -15 °C (Without Heating); Minimum Bending Radius: 7.5 Cable Diameters; Flammability: Does Not Propagate Combustion When Laid Alone; Flexibility: Flexible (Stranded Core)., Rated Current: 40.0 A; Number Of Poles: 3; Response Characteristic (Current Curve): C; Rated Operating Voltage: 400 V; Voltage Type: Alternating/Direct (Ac/Dc); Frequency: 50 Hz; Rated Breaking Capacity (En 60898): 4.5 Ka; Rated Impulse Withstand Voltage: 4 Kv; Release Type: Thermal And Electromagnetic; Connection Type: Screw Connection; Max. Incoming Cable Cross-Section: 25 Mm²; Installation Depth (Niches): 73.6 Mm; Width By Number Of Modules: 3; Degree Of Protection: Ip20; Response Time In The Short Circuit Zone (Tm): 0.1 S; Current Limiting Class: 3; Climatic Version: Uhl4; Energy Loss: 22.5 W; Suitable For Safety Switch Engine: Yes; Additional Equipment Possible: Yes, Rated Current: 32.0 A; Number Of Poles: 1; Response Characteristic (Current Curve): C; Rated Operating Voltage: 230 V; Voltage Type: Alternating/Direct (Ac/Dc); Frequency: 50 Hz; Rated Breaking Capacity (En 60898): 4.5 Ka; Rated Impulse Withstand Voltage: 4 Kv; Release Type: Thermal And Electromagnetic; Connection Type: Screw Connection; Max. Incoming Cable Cross-Section: 25 Mm²; Installation Depth (Niches): 73.6 Mm; Width By Number Of Modules: 1; Degree Of Protection: Ip20; Response Time In The Short Circuit Zone (Tm): 0.1 S; Current Limiting Class: 3; Climatic Version: Uhl4; Energy Loss: 6.0 W; Suitable For Safety Switch Engine: Yes; Additional Equipment Possible: Yes, Rated Voltage: 0.66 Kv (660 V); Rated Primary Current: 1000 A; Rated Secondary Current: 5 A; Transformation Ratio: 1000/5; Accuracy Class: 0.5; Rated Secondary Load: Not Less Than 10 Va; Nominal Frequency: 50 Hz; Climatic Version: U3 (Use In Enclosed Spaces); Phase Type: Single-Phase; Body Material: Low-Flammability, Self-Extinguishing Plastic; Design Features: The Presence Of A Protective Transparent Cover On The Terminals Of The Secondary Terminals With Holes For Sealing; Contents: Product Passport With Initial Verification Mark, Set Of Fastenings.

Key Value

Tender Value
16,54,900 - KZT

Attachment

FileName File Description
Global Tender Document 8421f8df-e179-4acc-97b5-63183eb411aa.html
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail

WhatsApp