GTR 112005825
Request For Quotation Purchase Of A Medical Device For The Biochemical Analyzer Dirui Cs-T240.
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
112005825
Tendering Authority
Subscribe to view
Tender No
16844536
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of A Medical Device For The Biochemical Analyzer Dirui Cs-T240.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
22-04-2026
Closed
Work Detail
High Density Lipoprotein-Cholesterol - Hdl-C. Packing - No. 366. The Reagent Is Used For Quantitative In Vitro Measurement Of The Concentration Of High-Density Lipoprotein Cholesterol (Hdl-C) Contained In Human Serum On The Dirui Cs-T240 Biochemical Analyzer. High-Density Lipoprotein Cholesterol In The Sample Is Selectively Catalyzed And Hydrolyzed By Cholesterol Esterase Into Cholesterol And Free Fatty Acid Under The Influence Of The Surfactant In The Reagent. Components: R1 - 4-Aminoantipyrine 1Mmol/L; Cholesterol Oxidase 1 Unit/L; Cholesterol Sterase 1 Kg/L; Peroxidase 4 Ku/L; Nonionic Surfactant 0.5%; Polymer Compound Required Quantity; Buffer Mops 100 Mmol/L. R2 - Dsbmt 1.2%; Nonionic Surfactant 0.5%; Buffer Mops 100 Mmol/L. The Test Time Is 300 Seconds. Volume R1-150 Ml. Volume R2-50 Ml. Sample Volume Is 4 Μl. The Number Of Tests In The Package Is No More Than 366. Calibrator In The Kit. Reagent Control Is Carried Out On Control For Lipids Level 1 And 2. Calibrator And Control From The Manufacturers Factory With Certified Values Of The Control Material And A Calibrator With A Target Value. The Linear Range Of This Reagent Is 0-150 Mg/Dl. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. The Distance Between The Bottom Of The Bottle And The Barcode Should Be Within The Range Of 15Mm-25Mm. The Purchase Of Goods Includes A Related Service: The Visit Of A Certified Specialist To Adapt The Reagent. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Low Density Lipoprotein-Cholesterol-Ldl-C. Packing - No. 366. The Reagent Is Used For Quantitative In Vitro Measurement Of The Concentration Of Low-Density Lipoprotein Cholesterol (Ldl-C) Contained In Human Serum On The Dirui Cs-T240 Biochemical Analyzer. Low-Density Lipoprotein Cholesterol In The Sample, Under The Influence Of The Surfactant In The Reagent, Is Selectively Catalyzed And Hydrolyzed By Cholesterol Esterase Into Cholesterol And Free Fatty Acid. Components: Reagent 1 - 4-Aminoantipyrine 1 Mmol/L; Cholesterol Oxidase 500 Units/L; Cholesterol Sterase 800 Units/L; Peroxidase 800 U/L; Nonionic Surfactant 0.5% Polymer Compound Required Amount; Buffer Mops 100 Mmol/L. Reagent 2-Dsbmt 1.2%; Nonionic Surfactant 0.5%; Buffer Mops 100 Mmol/L. The Test Time Is 300 Seconds. Volume R1 - 150 Ml. Volume R2 - 50 Μl. Sample Volume - 4 Μl. The Number Of Tests Per Package Is No More Than 366. Calibrator Included. Reagent Control Is Carried Out On Control For Lipids Level 1 And 2. Calibrator And Control From The Manufacturers Factory With Certified Values Of The Control Material And A Calibrator With A Target Value. The Linear Range Of This Reagent Is 0-450 Mg/Dl. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. The Distance Between The Bottom Of The Bottle And The Barcode Should Be Within The Range Of 15Mm-25Mm. The Purchase Of Goods Includes A Related Service: The Visit Of A Certified Specialist To Adapt The Reagent. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99
Key Value
Tender Value
441,514 - KZT
Tender Documents
Global Tender Document
3d3890a1-88b2-4569-b4be-7f71670b1598.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.