GTR 112004975

Request For Quotation Purchase Of Goods (Security Equipment And Video Communications) For The Needs Of The Armed Forces Of The Republic Of Kazakhstan

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
112004975
Tendering Authority
Subscribe to view
Tender No
16845975
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Goods (Security Equipment And Video Communications) For The Needs Of The Armed Forces Of The Republic Of Kazakhstan
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
22-04-2026 Closed
Work Detail
Video Intercom Kit. Equipment: Monitor 1Xvdp-H2111w/ Calling Panel 1Xvdp-D2211/ Canopy 1Xds-Kabv6113-Rs/2X Power Supply, Type Of Communication - Simultaneous Transmission And Reception, Installation Method - Network Technology, Control - Touch. Inclusive Email Lock With Installation. Installation And Integration Of An Electronic Lock (Electromechanical Or Electromagnetic) With A Relay Of A Video Intercom Calling Panel For Remote Opening Of A Door/Wicket/Gate From The Monitor, The Hik-Connect Mobile Application And Using Mifare Cards. Wi-Fi 2.4 Ghz Support On The Monitor And Calling Panel. The Distance Between The Monitor And The Calling Panel Is Up To 80 M (By Air). • Electromechanical Lock (Electric Strike) - 12 V, Current Consumption Up To 0.5–1 A (Recommended). • Exit Button Is Normally Open (No). • Door Opening Sensor (Door Contact) - Magnetic Reed Switch (Optional, To Monitor The Door Status). Additional Equipment: • Poe Injector Or Poe Switch (If Poe Power Is Used). • Utp Cat5e/Cat6 Cable For Ethernet (Between Monitor And Call Panel). • Lock Cable: 2-Wire (For Relay) + Lock Power (Cross-Section ≥0.75–1.5 Mm² Depending On Distance). • 12 V Dc Power Supply For The Lock (Separate If The Lock Current Is >2 A Or The Distance Is Large). Connection Diagram 1. Power And Network: • Calling Panel: Poe From An Injector/Switch Or 12 V Dc. • Monitor: 12 V Dc Or Poe + Wi-Fi For Remote Access. 2. Connecting An Electronic Lock (To The Calling Panel): • Lock Relay On The Panel (Terminals: No / Com / Nc). • Power Supply To The Lock (+12 V From A Separate Power Supply) → Through The Panel Relay (Com + No) → Lock. • When The Relay Is Triggered (From The Monitor Or Via The Card), The Circuit Closes → The Lock Opens For 3–10 Seconds (Adjustable). • For An Electromagnetic Lock: • The Panel Relay Is Used To Open The Locks Power Circuit (Nc Mode) When Opening. • Exit Button: In Parallel With The Relay (To The Corresponding Panel Terminals). (Installation And Commissioning Including Consumables)., Electromagnetic Lock With Installation. Installation And Integration Of An Electronic Lock (Electromechanical Or Electromagnetic) With A Relay Of A Video Intercom Calling Panel For Remote Opening Of A Door/Wicket/Gate From The Monitor, The Hik-Connect Mobile Application And Using Mifare Cards. Wi-Fi 2.4 Ghz Support On The Monitor And Calling Panel. The Distance Between The Monitor And The Calling Panel Is Up To 80 M (By Air). • Electromechanical Lock (Electric Strike) - 12 V, Current Consumption Up To 0.5–1 A (Recommended). • Exit Button Is Normally Open (No). • Door Opening Sensor (Door Contact) - Magnetic Reed Switch (Optional, To Monitor The Door Status). Additional Equipment: • Poe Injector Or Poe Switch (If Poe Power Is Used). • Utp Cat5e/Cat6 Cable For Ethernet (Between Monitor And Call Panel). • Lock Cable: 2-Wire (For Relay) + Lock Power (Cross-Section ≥0.75–1.5 Mm² Depending On Distance). • 12 V Dc Power Supply For The Lock (Separate If The Lock Current Is >2 A Or The Distance Is Large). Connection Diagram 1. Power And Network: • Calling Panel: Poe From An Injector/Switch Or 12 V Dc. • Monitor: 12 V Dc Or Poe + Wi-Fi For Remote Access. 2. Connecting An Electronic Lock (To The Calling Panel): • Lock Relay On The Panel (Terminals: No / Com / Nc). • Power Supply To The Lock (+12 V From A Separate Power Supply) → Through The Panel Relay (Com + No) → Lock. • When The Relay Is Triggered (From The Monitor Or Via The Card), The Circuit Closes → The Lock Opens For 3–10 Seconds (Adjustable). • For An Electromagnetic Lock: • The Panel Relay Is Used To Open The Locks Power Circuit (Nc Mode) When Opening. • Exit Button: In Parallel With The Relay (To The Corresponding Panel Terminals). (Installation And Commissioning Including Consumables).
Key Value
Tender Value
480,000 - KZT
Tender Documents
Global Tender Document
243eef7c-97e8-4137-a35c-a868b66f85da.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders