Foley Catheter, 2-Way Single Use, Sterile, Size: No. 18, Latex With Silicone Coating, With Tiemann Tip, Silicone., Vicrol. Suture Surgical Material, Absorbable 2/0, 75 Cm, Needle 30 Mm Cutting 3/8, Medical Scalpel, Disposable, With Removable Blade No. 11. Designed For Cutting Soft Tissues And Blood Vessels During All Types Of Surgical Operations, For Cutting Soft Tissues During All Types Of Surgical Interventions. The Blade Is Made Of Durable Stainless Steel., Sterile Sheet Size 200*180 Cm. Made From Non-Woven Material Of The Sms Type, With A Density Of At Least 28 G/M., Non-Absorbable Suture Material (Lavsan) 2(5) 75 Cm Needle 45 Mm Stabbing 1/2, Intravenous Peripheral Catheter-Cannula G No. 18 With Injection Valve, Surgical Gloves Latex Sterile Anatomical, Size 7. For Work For Medical And Surgical Purposes. Purpose - Surgical Anatomical - Division Into Right And Left Hands. The Cuff Is Standard, With A Roller. Coating: Powder-Free, Without Powder - Reduces The Risk Of Allergic Reactions And Skin Irritations. Sterile - Sterilization - Ethylene Oxide, Increased Sensitivity - 20% Thinner Than A Regular Surgical Glove, The Inner Surface Is Chlorinated. The Length Of The Glove From The Tip Of The Middle Finger To The Roller Is 280 Mm - 300 Mm. Single Finger Thickness (13Mm From Tip): 0.15 ± 0.02Mm. Single Palm Thickness (Center): 0.13 ± 0.02Mm. Single Cuff Thickness (25 Mm From The Bolster): 0.11 ± 0.02 Mm. External Surface Finish: Textured, Micro-Roughened Surface Over The Entire Area. Without Adhesive Strip. Internal Polymer Coating - A Specialized Internal Coating To Make It Easier To Put On The Glove. Strength Factor - Aql - 1.0 (Air Pump Test). Tightness: Standard G1. Standard: Astm D3578-05 (2015). Glove Weight: 8.5 ± 0.2G. Availability Of Iso 13485:2003, 9001:2000 Certificate. The Color Of The Product Is Natural. Sterile Surgical Gloves Have An Increased Length, Which Perfectly Protects The Forearm, Without A Cushion. Sterile Surgical Gloves Have A Texture Over The Entire Surface Of The Glove, Which: - Ensures Reliable Grip Of The Instrument And Safety Of Manipulation; -The Texture On The Back Of The Glove Eliminates Glare On The Surface. The High Sensitivity Of The Surgical Glove Is Ensured By A Micro-Textured Surface, Which Also Facilitates Grip., Vacuum Tube With Coagulation Activator, 6 Ml, Red, Three-Component Sterile Injection Syringe For Single Use Volumes: 5 Ml; With Needles 22Gx11/2 The Syringe Is Made Of High Quality Plastic And Consists Of A Piston, A Rubber Sealing Ring And A Graduated Cylinder. The Triangular Sharpened Needle Is Coated With A Thin Layer Of Silicone., Vacuum Tube For Studying The Hemostasis System With Sodium Citrate 3.8%, 3.5 Ml, Blue, Vicrol. Suture Surgical Material, Absorbable 3/0(2) 75 Cm Needle 26Mm Stabbing 1/2, Medical Extension Cord With “Luer-Lock” Female And “Luer-Lock” Male Tips, 1500 Mm Long. The Medical Extension (Infusion Line) Is Designed To Connect The Infusion Source (Infusion System, Syringe Pump Syringe) With An Intravenous Catheter. The Extension Tube Is Transparent, Made Of Medical Grade Pvc That Is Resistant To Bending. Inner Diameter -1.57 Mm, Length -1500Mm. Resistant To Pressure Up To 4 Bar. The Ends Of The Extension Cord Are Equipped With Luer-Lock Tips (Connectors) (Male/Female) With Protective Caps, Non-Absorbable Suture Material (Lavsan) 1(4) 75 Cm Needle 40 Mm Stabbing 1/2, A Disposable Block For Protecting The Endoscope From Damage (Mouthpiece) Without The Use Of Latex Material Helps Protect Expensive Endoscopic Equipment From Mechanical Damage From The Patient’S Teeth. The Polypropylene Fixing Disk Of The Endoscope Protection Block From Damage (Mouthpiece) Maintains The Position Of The Open Oral Cavity, While The Side Holes Of The Endoscope Protection Block Easily Allow The Use Of Additional Suction Equipment. For Comfortable And Safe Use, Use A Soft Fixing Strap, With The Ability To Adjust To The Size Of The Patient’S Head. The Disposable And Individually Packaged Endoscope Damage Protection Unit Is Designed For Single Use, Which Reduces The Risk Of Cross-Contamination (Secondary Contamination). Features And Benefits: Ease Of Use, Comfortable And Secure Position Of The Block Between The Teeth, Soft Elastic Strap With Holes For Adjusting The Size Of The Retainer, Single Use, Non-Toxic Polypropylene-Based Plastic Material, Latex-Free Material, Container For Collecting Biological Material. Non-Sterile, Single Use, 60 Ml Volume, Vicrol. Suture Surgical Material, Absorbable 3/0, 75 Cm Needle 26 Mm Cutting 3/8, Disposable Sterile Connecting Tube With A T-Connector To A Sterile Disposable Polymer Container, For Radiopaque Substances To The Injection System. Equipment: High Pressure Line With T Connector. The Length Of The Line Is 150 Cm. The Internal Diameter Of The Tube Is 0.060 ± 0.002 Inches. The Outer Diameter Of The Tube Is 0.100 ± 0.002 Inches. The Material Of Manufacture Of The Connector And Tube Is Polyvinyl Chloride. Maximum Design Pressure, Not Less Than 300 Psi. The Maximum Speed Of Contrast Agent Administration Is Not Less Than 10.0 Ml/S. Shelf Life From The Date Of Sterilization Is At Least 4 Years. Sterilization – Factory (Ethylene Oxide) Individual Packaging, Sterile., 21G X 1 1/2 (0.8Mm X 38Mm) Reversible Clear Chamber Needle Without Holder, Medical Hypoallergenic Adhesive Plaster 2.5Cmx5m, Vicrol. Suture Surgical Material, Absorbable 4/0, 75 Cm Needle 18 Mm Cutting 3/8