Fluorocell Wdf Coloring Reagent. Reagent For Staining Leukocytes In Diluted Blood Samples For Differential Counting Of Leukocytes In 4 Populations Using Automatic Hematology Analyzers Of The Xn Series For The Xn-1000, Xn-1500, Xn-2000, Xn-3000, Xn-3100, Xn-9000, Xn-9100 Systems. Packaging 2X42 Ml., Fluorocell Wnr Coloring Reagent. The Reagent Is Used To Stain Nucleated Cells After A Lysis Reaction. The Nuclear And Granular Contents Of Cells Are Stained, Which Allows Cells To Be Differentiated Due To The Intensity Of Their Staining And Internal Cellular Complexity. After Reactions With Reagents And Cell Analysis Using Fluorescence Flow Cytometry, Different Cell Populations Are Placed On A Wnr Channel Scattergram Based On Their Forward Light Scatter (Fls) And Lateral Fluorescence (Sfl), Allowing The Determination Of White Blood Cell Count (Wbc#), Nucleated Red Blood Cell Count (Nrbc#), Basophil Count (Baso#), Nucleated Red Blood Cell Count (Nrbc%) And Percentage Basophils (Baso%). Composition: Polymethine 0.005%, Ethylene Glycol 99.9%. Storage Conditions: The Closed Reagent Is Stored At 2-35°C Until The Expiration Date; Once Opened, The Reagent Is Stable For 90 Days. Packaging: 2X82 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software., Xn Check L3 (Control Blood Xn Check L3). The High Range (Level 3) Control Material Is Intended For Use As A Hematology Control Blood For Cbc, Differential, Reticulocyte, Nrbc, And Mi-Rbc* Counts Using The Sysmex Xr Series, Xn Series, And Xn-L Series Instruments. The Use Of Stabilized Cell Preparations To Control Hematology Equipment Is A Common Procedure. Composition: Stabilized Human Erythrocytes, Human Leukocytes, Platelets And Nucleated Erythrocytes In A Preservative Medium. Storage Conditions: Unopened Control Material Is Stored At 2-8°C Until The Expiration Date; After Opening, The Control Reagent Is Stable For 7 Days. Packaging: 1X3 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Test Material Supplied Must Be Compatible With The Version Of The Installed Software., The Reagent Hemolyzes Red Blood Cells, Pre-Diluted The Sample 1:60, And The Membranes Of Leukocytes Become Permeable, Allowing Fluorocell Wdf To Penetrate The Cells For Further Staining. Following Reactions With Reagents And Cell Analysis Using Fluorescence Flow Cytometry, Different Cell Populations Are Placed On A Wdf Channel Scattergram Based On Their Side Scatter Light (Ssc) And Side Fluorescence Light (Sfl). Composition: Quaternary Organic Ammonium Salts 0.07%, Nonionic Surfactant 0.17%. Storage Conditions: The Closed Reagent Is Stored At 2-35°C Until The Expiration Date; Once Opened, The Reagent Is Stable For 90 Days. Packing: 1X5 L. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software., Lysing Reagent Lysercell Wnr. The Reagent Lyses Red Blood Cells By First Diluting The Sample 1:60, And The Leukocyte Membranes Become Permeable, Allowing Fluorocell Wdf To Penetrate The Cells For Further Staining. Following Reactions With Reagents And Cell Analysis Using Fluorescence Flow Cytometry, Different Cell Populations Are Placed On A Wnr Channel Scattergram Based On Their Forward Light Scattering (Fls) And Lateral Fluorescence (Sfl). Composition: Quaternary Organic Ammonium Salts 0.20%, Nonionic Surfactant 0.10%. Storage Conditions: The Closed Reagent Is Stored At 2-35°C Until The Expiration Date; After Opening, The Reagent Is Stable For 60 Days. Packing: 1X5 L. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software., Reagent For Determining Hemoglobin Concentration In Blood Sulfolyser. The Reagent Is Used In The Xn-Cbc Channel To Obtain A Hemoglobin Result Using Spectrophotometry. The Key Component Is Sodium Lauryl Sulfate, A Molecule That Has Hydrophobic/Hydrophilic Parts. When Mixed With A Sample, Sls Causes Red Blood Cell Lysis, Allowing The Hydrophobic Moiety To Attach To The Globin Molecule. This Causes A Conformational Change In The Globin Molecule, Which Leads To The Oxidation Of The Heme Group From Fe2+ To Fe3+. After Oxidation, The Hydrophilic Moiety Of Sls Attaches To The Heme Group, Forming A Stable Colored Complex, Which Is Then Passed Through A Spectrophotometer And Read At A Wavelength Of 555 Nm. Composition: Sodium Lauryl Sulfate 1.7 G/L. Storage Conditions: Unopened Reagent Is Stored For 12 Months From The Date Of Manufacture At 1-30°C; After Opening, The Reagent Is Stable For 60 Days. Packing: 3X5 L. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software., Control Blood Xn Check L1. Low Range (Level 1) Control Material Is Intended For Use As A Hematology Control Blood For Cbc, Differential, Reticulocyte, Nrbc, And Mi-Rbc* Counts Using The Sysmex Xr Series, Xn Series, And Xn-L Series Instruments. The Use Of Stabilized Cell Preparations To Control Hematology Equipment Is A Common Procedure. Composition: Stabilized Human Erythrocytes, Human Leukocytes, Platelets And Nucleated Erythrocytes In A Preservative Medium. Storage Conditions: Unopened Control Material Is Stored At 2-8°C Until The Expiration Date; After Opening, The Control Reagent Is Stable For 7 Days. Packaging: 1X3 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Test Material Supplied Must Be Compatible With The Version Of The Installed Software., Whole Blood Diluent Cellpack Dcl. The Reagent Is Used In The Xn-Cbc Channel To Analyze The Number And Size Of Red Blood Cells And Platelets Using The Hydrodynamic Focusing Method. In Addition, It Is Used As A Focusing Fluid On Automated Hematology Analyzers, And Also Protects Red Blood Cell And Platelet Cells, Prevents Backflow, Acts As An Isotonic Diluent, And Flushes Analyzer Lines Between Each Sample. Composition: Maleic Acid <10%. Storage Conditions: The Closed Reagent Is Stored At 2-35°C Until The Expiration Date; After Opening, The Reagent Is Stable For 60 Days. Packing: 1X20 L. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software., Cellclean 50 Ml. Cleaning Solution For Sysmex Automated Hematology Systems, Used To Clean The Internal System Of The Analyzer To Prevent Sedimentation Of Organic Matter From Sample Debris Or Bacterial Growth. Composition: Sodium Hypochlorite (Active Chlorine Concentration 5.0%). Storage Conditions: The Closed Solution Is Stored At 2-35°C In A Dark Place For 12 Months From The Date Of Manufacture; After Opening, The Reagent Is Stable For 60 Days. Packaging: 1X50 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software., Control Blood Xn Check L2. Normal Range (Level 2) Control Material Is Intended For Use As A Hematology Control Blood For Cbc, Differential, Reticulocyte, Nrbc, And Mi-Rbc* Counts Using The Sysmex Xr Series, Xn Series, And Xn-L Series Instruments. The Use Of Stabilized Cell Preparations To Control Hematology Equipment Is A Common Procedure. Composition: Stabilized Human Erythrocytes, Human Leukocytes, Platelets And Nucleated Erythrocytes In A Preservative Medium. Storage Conditions: Unopened Control Material Is Stored At 2-8°C Until The Expiration Date; After Opening, The Control Reagent Is Stable For 7 Days. Packaging: 1X3 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Test Material Supplied Must Be Compatible With The Version Of The Installed Software.