GTR 111756860
Tenders Are Invited For Calibrators Cobas Pro (E 802) And Cobas Pure (E 402)
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
111756860
Tendering Authority
Subscribe to view
Tender No
16779248
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Calibrators Cobas Pro (E 802) And Cobas Pure (E 402)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
23-04-2026
Closed
Work Detail
Cea Calset Calibrator, 4X1.0 Ml. Reagents For The Cobas Pro/Pure.. Analyzer. Purpose: The Cea Calset Calibrator Set Is Intended For Calibration Elecsys Cea Quantitative Test On Cobas E Immunochemical Analyzers. Cea Calset Is A Buffer/Protein Matrix With Added Cea In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Cea Cal1: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 1 ▪ Cea Cal2: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 2. Cea (Human, From Cell Culture) In Two Ranges Concentrations (About 5 Ng/Ml And About 50 Ng/Ml) In The Buffer/Protein Matrix. 1 Ng/Ml Cea Corresponds To 16.9 Miu/Ml. Calibrators Are Supplied Ready For Use In Bottles Compatible With The System. Storage And Stability: Store At 2‑8 °C. Stability: Unopened At 2‑8 °C Until The Expiration Date Indicated, Open/In Aliquots At 2‑8 °C For 12 Weeks, On Board The Analyzer At 20‑25 °C For Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Testosterone Ii Calset Calibrator, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer. Purpose: The Testosterone Ii Calset Ii Calibration Kit Is Intended For Calibration Of The Elecsys Testosterone Ii Quantitative Test On Cobas E Immunochemical Analyzers. Testosterone Ii Calset Ii Consists Of Lyophilized Human Serum Supplemented With Testosterone In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Testo Cal1: 2 Bottles, Each 1.0 Ml Of Calibrator 1 ▪ Testo Cal2: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 2. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Refurbished Calibrators: At -20 °C (± 5 °C) 3 Months, On Board Analyzers At 20‑25 °C Use Only Once. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Hgh Calset Calibrator, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure.. Analyzer. Purpose: The Hgh Calset Calibration Kit Is Intended For Calibration Quantitative Analysis Of Elecsys Hgh On Immunochemical Analyzers Cobas E. The Hgh Calset Is Lyophilized Human Serum Supplemented With Recombinant Human Growth Hormone (Hgh) In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Hgh Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Hgh Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. Hgh (Recombinant Peptide) In Two Concentration Ranges (About 0 Ng/Ml Or 0 Pg/Ml And About 10 Ng/Ml Or 10,000 Pg/Ml) In The Matrix Human Blood Serum; Preservative To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (±5 °C) 28 Days, At 2-8 °C 7 Days, On Board The Analyzer At 20‑25 °C For Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Folate Iii Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer.. Purpose: The Folate Iii Calset Calibration Set Is Intended For Calibration Quantitative Analysis Of Elecsys Folate Iii On Immunochemical Analyzers Cobas E. The Folate Iii Calset Calibration Kit Consists Of Lyophilized Human Serum With The Addition Of Folates In Two Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Fol Iii Cal1: 2 Bottles, Each With 1.0 Ml Of Calibrator 1 ▪ Fol Iii Cal2: 2 Bottles, Each With 1.0 Ml Of Calibrator 2 Folic Acid Salt In Two Concentration Ranges (< 9.1 Nmol/L Or <4.0 Ng/Ml And Approximately 38.5 Nmol/L Or 17.0 Ng/Ml) In Human Serum. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C 3 Months, At 2‑8 °C 3 Days, On Board Analyzers At 20‑25 °C Use Only Once. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Ferritin Calset Calibrator, 4 X 1 Ml. Reagents For The Cobas Pro/Pure Analyzer.. Purpose: The Ferritin Calset Calibrator Set Is Intended For Calibration Elecsys Ferritin Quantitative Test On Cobas E Immunochemical Analyzers. The Ferritin Calset Is Human Serum With Added Ferritin In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Ferr Cal1: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 1 ▪ Ferr Cal2: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 2. Calibrators Are Supplied Ready For Use In Bottles Compatible With The System. Storage And Stability: Store At 2‑8 °C. Stability: Unopened At 2‑8 °C Until The Expiration Date Indicated, Open At 2‑8 °C For 12 Weeks, On Board The Analyzer At 20‑25 °C For Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Pth Calset, 4X1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer.. Purpose: The Calset Pth Calibration Kit Is Intended For Calibration Elecsys Pth Quantitative Analysis For The Determination Of Intact Pth (Parathyroid Hormone) On Cobas E Immunochemical Analyzers. The Calset Pth Calibration Kit Consists Of Lyophilized Human Serum With The Addition Of Synthetic Pth In Two Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Pth Cal1: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 1 ▪ Pth Cal2: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 2. Pth (Synthetic Peptide, Human Sequence) In Two Concentration Ranges (Approximately 1 Pmol/L Or 10 Pg/Ml And Approximately 466 Pmol/L Or 4400 Pg/Ml) In A Human Serum Matrix; Preservative To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Refurbished Calibrators: At -20 °C ± 5 °C 12 Weeks, At 2‑8 °C 14 Days, On Board The Analyzer At 20‑25 °C Up To 6 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Troponin I Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer.. Purpose The Troponin I Stat Calset Calibration Kit Is Intended For Calibration Of The Elecsys Troponin I Stat Quantitative Assay On Cobas E Immunochemical Analyzers. The Troponin I Stat Calset Calibration Kit Consists Of Lyophilized Human Serum With The Addition Of Troponin I In Two Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions ▪ Tn I Cal1: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 1 ▪ Tn I Cal2: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 2 Troponin I (Recombinant Human) In Two Concentration Ranges (Approximately 0.4 Μg/L Or Ng/Ml And Approximately 30 Μg/L Or Ng/Ml) In A Matrix Of Human Serum. Storage And Stability Store At 2 - 8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Diluted Calibrators: Either At 20 °C For 3 Days (Freeze Only Once) Or At 2 8 °C For 4 Days On Board The Analyzers At 20 25 °C For Up To 5 Hours. In Case The Product Does Not Comply With The Technical Specifications, Replace The Product Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Total Psa Ii Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure.. Analyzer. Purpose: The Total Psa Calset Ii Calibrator Set Is Intended For Calibration Quantitative Elecsys Total Psa Test On Immunochemical Analyzers Cobas E. Total Psa Calset Ii Is Lyophilized Human Serum With The Addition Of Human Prostate-Specific Antigen (Psa) In Two Concentrations. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Psa Cal1: 2 Bottles, To Obtain 1.0 Ml Of Calibrator 1 Each ▪ Psa Cal2: 2 Bottles, To Obtain 1.0 Ml Of Calibrator 2 Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 12 Weeks, At 2‑8 °C 6 Weeks, On Board The Analyzer At 20‑25 °C Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Ca 72-4 Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer. Purpose The Ca 72 4 Calset Calibrator Set Is Intended For Calibration Of The Elecsys Ca 72 4 Quantitative Test On Cobas E Immunochemical Analyzers. Theoretical Rationale The Ca 72 4 Calset Calibrator Set Is Lyophilized Human Blood Serum With Added Human Ca 72 4 In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions ▪ Ca72 4 Cal1: 2 Bottles, For The Preparation Of 1.0 Ml Of Calibrator 1 Each ▪ Ca72 4 Cal2: 2 Bottles, For The Preparation Of 1.0 Ml Of Calibrator 2 Each Ca 72 4 (Human) In Two Concentration Ranges (About 1 U/Ml And About 70 U/Ml) In A Human Serum Matrix; Preservative Storage And Stability Store At 2 - 8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At 2 8 °C 6 Weeks Stability Of Dissolved Calibrators: On Board The Analyzer At 20 25 °C Up To 5 Hours In Case Of Product Non-Compliance With Technical Specifications, Replacement Of The Product Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Afp Ii Calset, 4 X 1 Ml. Reagents For The Cobas Pro/Pure Analyzer.. Purpose: The Afp Calset Ii Calibrator Set Is Intended For Calibration Elecsys Afp Quantitative Test On Cobas E Immunochemical Analyzers. Afp Calset Ii Is Lyophilized Human Serum With Added Human Afp (From Cell Culture) In 2 Concentrations. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions: Afp Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each Afp Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. Afp (Human, From Cell Culture) In 2 Ranges Concentrations (About 5 Iu/Ml Or 6 Ng/Ml And About 50 Iu/Ml Or 60 Ng/Ml) In The Human Serum Matrix. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 12 Weeks, At 2-8 °C 6 Weeks, On Board The Analyzer In Case The Product Does Not Comply With The Technical Specifications, Replace The Product Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Ft4 Ii Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer.. Purpose: The Calset Ft4 Iii Calibrator Set Is Intended For Calibration Elecsys Ft4 Iii Quantitative Test On Cobas E Immunochemical Analyzers. Calset Ft4 Iii Is A Ready-To-Use Buffer/Protein Matrix With Two Concentrations Of L-Thyroxine Added To It. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Ft4 Iii Cal1: 2 Bottles, 1.0 Ml Of Calibrator 1 In Each ▪ Ft4 Iii Cal2: 2 Bottles, 1.0 Ml Of Calibrator 2 In Each. Calibrators Are Supplied Ready For Use In Bottles Compatible With The System. Storage And Stability: Store At 2‑8 °C. Stability: Unopened At 2‑8 °C Until Expiration Date Indicated, Unopened/In Aliquots At 2‑8 °C 12 Weeks, On Board The Analyzer At 20‑25 °C Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Anti-Tg Calset, 4 X 1.5 Ml. Reagents For The Cobas Pro/Pure.. Analyzer Purpose: The Anti‑Tg Calset Calibration Set Is Intended For Calibration Quantitative Elecsys Anti-Tg Test On Cobas Pro Immunochemical Analyzers. Anti-Tg Calset Is A Lyophilized Human Serum Matrix With Added Anti-Thyroglobulin (Anti-Tg) Antibodies In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Level 1 Calibrator A‑Tg Cal1: 2 Bottles, For Preparation 1.5 Ml Calibrator 1 Each ▪ Level 2 Calibrator A‑Tg Cal2: 2 Bottles, To Prepare 1.5 Ml Calibrator 2 Each Anti-Tg Antibodies (A‑Tg Cal1: Human, A‑Tg Cal2: Sheep) In Two Concentration Ranges (Approximately 40 Iu/Ml And Approximately 3250 Iu/Ml) In Matrix Of Human Blood Serum. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At 2‑8 °C 6 Weeks, On Board The Analyzer Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Anti-Tpo Calset, 4 X 1.5 Ml. Reagents For The Cobas Pro/Pure.. Analyzer Purpose: The Anti‑Tpo Calset Calibration Set Is Used For Calibration Quantitative Elecsys Anti‑Tpo Test On Cobas Pro Immunochemical Analyzers. Anti-Tpo Calset Is A Lyophilized Human Serum Matrix With Added Anti-Thyroid Peroxidase (Anti-Tpo) Antibodies In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Level 1 Calibrator Anti‑Tpo Cal1: 2 Bottles, Each For Preparing 1.5 Ml Of Calibrator 1 ▪ Level 2 Calibrator Anti‑Tpo Cal2: 2 Bottles, Each For Preparing 1.5 Ml Of Calibrator 2. To Prepare The Calibrator, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 8 Weeks, At 2‑8 °C Up To 8 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Vitamin B12 Ii Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure.. Analyzer. Purpose: Vitamin B12 Ii Calset Is Intended For Calibration Of Quantitative Elecsys Vitamin B12 Ii Analysis On Cobas E Immunochemical Analyzers. Vitamin B12 Ii Calset Is A Lyophilized Matrix Of Human Serum Supplemented With Vitamin B12 In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ B12 Ii Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ B12 Ii Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 84 Days, At 2‑8 °C 72 Hours, On Board Analyzers At 20‑25 °C Use Only Once. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Tsh Calset, 4 X 1.3 Ml. Reagents For The Cobas Pro/Pure.. Analyzer. Purpose: The Tsh Calset Calibration Set Is Intended For Calibration Quantitative Analysis Of Elecsys Tsh On Immunochemical Analyzers Cobas E. Tsh Calset Consists Of An Equine Serum Matrix (Tsh Cal1) And A Human Serum Matrix With Human Tsh (Tsh Cal2) In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Tsh Cal1: 2 Bottles, Each Containing 1.3 Ml Of Calibrator 1 ▪ Tsh Cal2: 2 Bottles, Each Containing 1.3 Ml Of Calibrator 2. Calibrators Are Supplied Ready For Use In Bottles Compatible With The System. Storage And Stability: Store At 2‑8 °C. Stability: Unopened At 2‑8°C Until Expiration Date, Once Opened/In Aliquots At 2‑8°C For 12 Weeks, On-Board At 20‑25°C For Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Vitamin D Total Ii Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer.. Purpose: The Vitamin D Total Calset Calibration Set Is Intended For Calibration Of The Elecsys Vitamin D Total Quantitative Analysis On Cobas E Immunochemical Analyzers. Vitamin D Total Calset Matrix Is A Lyophilized Matrix Human Serum Supplemented With 25‑Oh Vitamin D3 In Two Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Vit‑D Total Cal1: 2 Bottles, Each With 1.0 Ml Of Calibrator 1 ▪ Vit‑D Total Cal2: 2 Bottles, Each With 1.0 Ml Of Calibrator 2. 25‑Oh Vitamin D3 In Two Concentration Ranges (Approximately 3 Ng/Ml Or 7.5 Nmol/L And Approximately 45 Ng/Ml Or 113 Nmol/L) In The Matrix Of Human Blood Serum; Preservative To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Refurbished Calibrators: At -20 °C ± 5 °C 90 Days, At 2‑8 °C 120 Hours, On Board The Analyzer At 20‑25 °C Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Ft3 Iii Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure.. Analyzer Purpose: The Ft3 Iii Calset Calibration Set Is Intended For Calibration Quantitative Analysis Of Elecsys Ft3 Iii On Immunochemical Analyzers Cobas E. The Ft3 Iii Calset Consists Of Lyophilized Human Serum Supplemented With T3 In Two Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Ft3 Iii Cal1: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 1 ▪ Ft3 Iii Cal2: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 2. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At 2‑8 °C For 8 Weeks, On Board The Analyzer At 20‑25 °C For Up To 5 Hours. If The Product Does Not Comply With The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Prolactin Ii Calset, 4 X 1 Ml. Reagents For The Cobas Pro/Pure Analyzer. Purpose: The Prolactin Ii Calset Calibrator Set Is Intended For Calibration Elecsys Prolactin Ii Quantitative Test On Cobas E Immunochemical Analyzers. Prolactin Ii Calset Is A Lyophilized Buffered Horse Serum Matrix With Added Recombinant Prolactin In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Prl Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Prl Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 3 Months, On Board Analyzers At 20-25 °C Use Only Once. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Estradiol Iii Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure. Analyzer. Purpose: The Estradiol Iii Calset Calibrator Set Is Intended For Calibration Quantitative Test Elecsys Estradiol Iii On Immunochemical Analyzers Cobas E. The Estradiol Iii Calset Calibrator Set Is Lyophilized Human Serum With Added Estradiol In 2 Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions ▪ E2 Iii Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ E2 Iii Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At –20 °C (± 5 °C) 31 Days, At 2‑8 °C 24 Hours, On Board Analyzers At 20‑25 °C Use Only Once. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Hcg+Beta Calset, 4 X 1 Ml. Reagents For The Cobas Pro/Pure.. Analyzer. Purpose: The Hcg+Β Calset Calibration Set Is Intended For Calibration Quantitative Analysis Of Elecsys Hcg+Β On Immunochemical Analyzers Cobas E. The Hcg+Β Calset Calibrator Kit Is Lyophilized Human Serum With Added Hcg In Two Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Hcg+Β Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Hcg+Β Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. Human Chorionic Gonadotropin (Urine) In Two Concentration Ranges (About 1.5 Miu/Ml And About 2000 Miu/Ml) In A Buffered Human Serum Matrix. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At 2‑8 °C 12 Weeks, On Board The Analyzer At 20‑25 °C Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., C-Peptide Calset, 4 X 1 Ml. Reagents For The Cobas Pro/Pure.. Analyzer. Purpose: The C‑Peptide Calset Calibrator Set Is Intended For Calibration Elecsys C‑Peptide Quantitative Test On Cobas E Immunochemical Analyzers. C‑Peptide Calset Is A Lyophilized Horse Serum Matrix With Added C‑Peptide In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Cpeptid Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Cpeptid Cal2: 2 Bottles, For Preparing 1.0 Ml Calibrator 2 Each C-Peptide (Synthetic) In Two Concentration Ranges (About 0.167 Nmol/L Or 0.5 Ng/Ml And About 6.67 Nmol/L Or 20 Ng/Ml) In The Horse Serum Matrix. Distilled Water Must Be Added To Prepare Calibrators. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 1 Month, On Board Analyzers At 20-25 °C Use Only Once. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Ca 19-9 Calset, 4X1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer. Purpose: Set Of Calibrators Ca 19‑9 Calset. Designed For Calibration Quantitative Test Elecsys Ca 19‑9 On Immunochemical Analyzers Cobas E. The Ca 19‑9 Calset Is A Lyophilized Human Serum Supplemented With Human Ca 19‑9 In 2 Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Ca19‑9 Cal1: 2 Bottles, Each For 1.0 Ml Of Calibrator 1 ▪ Ca19‑9 Cal2: 2 Bottles, Each For 1.0 Ml Of Calibrator 2 Ca 19‑9 (Human) In 2 Concentration Ranges (About 20 U/Ml And About 250 U/Ml) In The Matrix Human Blood Serum; Preservative To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At –20 °C (± 5 °C) 2 Months, At 2‑8 °C 4 Weeks, On Board The Analyzer Cobas E 411 At 20‑25 °C Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Ca 15-3 Ii Calset, 4 X 1 Ml. Reagents For The Cobas Pro/Pure Analyzer. Purpose: Set Of Calibrators Ca 15‑3 Ii Calset. Designed For Calibration Quantitative Test Elecsys Ca 15‑3 Ii On Immunochemical Analyzers Cobas E. Ca 15‑3 Ii Calset Is A Ready-To-Use Human Serum Matrix Supplemented With Human Ca 15‑3 In 2 Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Ca 15‑3 Ii Cal1: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 1 ▪ Ca 15‑3 Ii Cal2: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 2. Ca 15‑3 (Human) In 2 Concentration Ranges (About 15 U/Ml And About 100 U/Ml) In Matrix Of Human Blood Serum. Calibrators Are Supplied Ready For Use In Bottles Compatible With The System. Store At 2‑8 °C. Stability: Unopened At 2‑8 °C Until Expiration Date Shelf Life After Opening/In Aliquots At 2‑8 °C 12 Weeks, On Board The Analyzer Cobas E 411 At 20‑25 °C Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Tacrolimus Calset Calibrator, 6 X 1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer. Purpose Tacrolimus Calset Calibrator Set. Designed For Calibration Of The Elecsys Tacrolimus Quantitative Test On Cobas E Immunochemical Analyzers. Theoretical Rationale Tacrolimus Calset Is A Lyophilized Calibrator Based On Human Blood With Added Tacrolimus In 2 Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions ▪ Tcl Cal1: 3 Bottles, For The Preparation Of 1.0 Ml Of Calibrator 1 Each ▪ Tcl Cal2: 3 Bottles, For The Preparation Of 1.0 Ml Of Calibrator 2 Each Tacrolimus In 2 Concentration Ranges (About 1 Ng/Ml And About 30 Ng/Ml) In The Human Blood Matrix; Preservative Storage And Stability Store At 2 - 8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 28 Days (Only One-Time Freezing Is Allowed) At 2 8 °C 7 Days At 20 25 °C 5 Days. If The Product Does Not Comply With The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Cyfra 21-1 Calset, 4X1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer. Purpose: Set Of Calibrators Cyfra 21‑1 Calset. Designed For Calibration Of The Elecsys Cyfra 21‑1 Quantitative Test On Cobas E Immunochemical Analyzers. The Cyfra 21‑1 Calset Calibrator Set Is Lyophilized Human Serum With Added Cytokeratin (Human, Mcf‑7 Cell Line) In 2 Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Cyfra Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Cyfra Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. Cytokeratin (Human, From The Mcf-7 Cell Line) In 2 Concentration Ranges (About 0 Ng/Ml And About 50 Ng/Ml) In The Serum Matrix Human Blood. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At 2‑8 °C 8 Weeks, On Board The Analyzer At 20‑25 °C Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Acth Calset Calibrator, 4 X 1 Ml. Reagents For The Cobas Pro/Pure Analyzer. Purpose: Set Of Acth Calset Calibrators. Designed For Calibration Quantitative Elecsys Acth Test On The Elecsys And Cobas E.Acth Immunochemical Analyzers. Calset Is A Lyophilized Horse Serum Matrix With Added Acth In Two Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Acth Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Acth Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. Acth (Synthetic) In Two Concentration Ranges (About 15 Pg/Ml And About 120 Pg/Ml) In The Horse Serum Matrix. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 1 Month, On Board Analyzers At 20-25 °C Use Only Once. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cortisol Ii Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer. Purpose: The Cortisol Ii Calset Calibrator Set Is Intended For Calibration Elecsys Cortisol Ii Quantitative Test On Cobas E Immunochemical Analyzers. The Cortisol Ii Calset Is Lyophilized Human Serum With Added Cortisol In 2 Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Cort Ii Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Cort Ii Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 3 Months, On Board Analyzers At 20‑25 °C Use Only Once. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Ca 125 Ii Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer. Purpose: Set Of Calibrators Ca 125 Ii Calset Ii. Designed For Calibration Quantitative Test Elecsys Ca 125 Ii On Immunochemical Analyzers Cobas E. Ca 125 Ii Calset Ii Is A Lyophilized Horse Serum Matrix (Ca125 Ii Cal1) And A Human Serum Matrix Supplemented With Human Ca 125 Protein (Ca125 Ii Cal2). Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Ca125 Ii Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Ca125 Ii Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At –20 °C (± 5 °C) 20 Weeks, At 2‑8 °C 12 Weeks, On Board The Cobas E 411 Analyzer At 20‑25 °C Up To 5 Hours. If The Product Does Not Comply With The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Pro Bnp Ii Calset, 4X1.0Ml. The Calset Probnp Ii Calibrator Set Is Designed To Calibrate The Elecsys Probnp Ii Quantitative Test On Cobas E Immunochemical Analyzers. The Calibrator Set Can Be Used With All Reagent Lots. Calset Can Be Used To Calibrate Both 9-Minute (Stat = Short Turn Around Time) And 18-Minute Applications. Packaging And Composition: ▪ Pbnpx Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Pbnpx Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each Probnp In 2 Concentration Ranges (About 16.6 Pmol/L Or 140 Pg/Ml And About 320 Pmol/L Or 2700 Pg/Ml) In The Horse Serum Matrix. Exact Calibrator Values For A Specific Series Are Available Via The Cobas Link. Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Use Immediately After Reconstitution Or Aliquot And Freeze At -20°C. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 3 Months (Only Single Freezing Is Allowed). Calset Probnp Ii, 4 Empty Bottles With Snap Caps And Labels, 2 X 6 Bottle Labels., Calibrator Insulin Calset, 4X1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer.. Purpose: The Insulin Calset Calibrator Set Is Intended For Calibration Elecsys Insulin Quantitative Test On Cobas E Immunochemical Analyzers. The Insulin Calset Is Lyophilized Bovine Serum With Added Insulin In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Insulin Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Insulin Cal2: 2 Bottles, To Prepare 1.0 Ml Calibrator 2 Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 3 Months, On Board Analyzers At 20-25 °C Use Only Once. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Lh Ii Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure. Analyzer. Purpose: The Lh Calset Ii Calibrator Set Is Intended For Calibration Quantitative Elecsys Lh Test On Immunochemical Analyzers Cobas E. Lh Calset Ii Is A Lyophilized Human Serum Matrix With Two Concentrations Of Human Lh Added. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Lh Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 In Each ▪ Lh Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 In Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 3 Months, On Board Analyzers At 20‑25 °C For Single Use Only. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Free Psa Calset, 4X1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer.. Purpose: The Free Psa Calset Calibration Set Is Intended For Calibration Quantitative Analysis Of Elecsys Free Psa On Immunochemical Analyzers Cobas E. The Free Psa Calset Is A Ready-To-Use Buffer/Protein Matrix Supplemented With Human Psa In Two Concentration Ranges. Calset Can Be Used With All Reagent Lots: Reagents - Working Solutions: ▪ Fpsa Cal1: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 1 ▪ Fpsa Cal2: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 2. Calibrators Are Supplied Ready To Use In Bottles Compatible With The System. Storage And Stability: Store At 2‑8 °C. Stability: Unopened At 2‑8 °C Until Expiration Date, Opened/In Aliquots At 2‑8 °C 12 Weeks, On Board The Analyzer At 20‑25 °C For Up To 5 Hours. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database., Calibrator Fsh Ii Calset, 4 X 1.0 Ml. Reagents For The Cobas Pro/Pure Analyzer.. Purpose: The Fsh Calset Ii Calibration Set Is Intended For Calibration Elecsys Fsh Quantitative Test On Cobas E Immunochemical Analyzers. Fsh Calset Ii Is A Lyophilized Horse Serum Matrix Supplemented With Follicle Stimulating Hormone In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Fsh Cal1: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 1 ▪ Fsh Cal2: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 2. To Prepare The Calibrator, You Must Add Distilled Water. Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Refurbished Calibrators: At -20 °C (± 5 °C) 3 Months, On Board Analyzers At 20‑25 °C Use Only Once. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Before Delivering The Reagent, Update The Analyzers Reagent Database.
Key Value
Tender Value
2,698,813 - KZT
Tender Documents
Global Tender Document
1f57b93f-4cf0-4a35-a748-50a1e4976be9.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.