GTR 111723114
Bids Are Invited For Acquisition Of Clinical Analysis Equipment For The Modernization Of The Municipal Laboratory Of Juacundá, Covering Essential Items Such As Analyzers (Biochemistry, Hematology, Ons) And Microscopy, With Financial Implementation Linked To Parliamentary Amendment No. 44040008, According To Proposal No. 11528843000124001.
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
111723114
Tendering Authority
Subscribe to view
Tender No
92026014/2026
Financer Name
Self-Funded
Work Title
Bids Are Invited For Acquisition Of Clinical Analysis Equipment For The Modernization Of The Municipal Laboratory Of Juacundá, Covering Essential Items Such As Analyzers (Biochemistry, Hematology, Ons) And Microscopy, With Financial Implementation Linked To Parliamentary Amendment No. 44040008, According To Proposal No. 11528843000124001.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
24-04-2026
Closed
Work Detail
Automatic Analyzer For Hematology Binocular Phase Contrast Biological Laboratory Microscope. Icom Observation Tube At Minimum 160 Mm Length With Binocular Head Tilted At 30 And 360 Degree Rotation, With Interpupillary Distance Adjustment And Diopter Adjustment For The Two Reverse Quadruple Revolver Eyepieces Flat Chromatic Phase Contrast Objectives 10Xph, 40X Retractable Ph And 100X Ph And Immersion, Type O.G 01 Pair Of Wide Field 10X Flat Eyepieces With 20 Mm Diameter, Allowing Configurable Magnifications Between 100X And 1000X (It Is Desirable To Have Optional Configuration Up To 1600X With 16X Eyepieces) Double Stage, Mechanical With Graduated Charriot With Control For X And Y Movements And Coaxial Adjustment Blade Fixation Micrometric And Macrometric Focusing, With Independent Knob, With Pressure Control (Torque) Exerted On The Coarse Adjustment And Safety Lock To Limit The Height And Thus Avoid Damage To The Objective Blade, The Vertical Adjustment Distance Of The Focus Must Be At Least 22 Mm, With A Minimum Division Of The Fine Adjustment Of 0.002 Mm. Polarization, Centralizing Eyepiece, Phase Contrast Turret Electric Koehler Illuminator With Spherical Collector Green And Blue Filters Lighting: Halogen Lamp Of At Least 6V/20W Or Led Of Equivalent Power, With Light Intensity Adjustment Power Cable With Double Insulation Instruction Manual And Cover To Cover The Microscope Power Supply To Be Defined By The Requesting Entity., Automatic Biochemical Analyzer Automatic Biochemical Analyzer, With Pipetting Speed Of At Least 180 Iphotometric Tests Per Hour Or More Minimum Of 60 Or More Simultaneous Positions With Refrigeration For Reagents, With A Separate On And Off Id Switch, Allowing To Turn Off The Equipment And Maintain The Refrigeration Of Active Reagents Tray With At Least 50 Positions For Primary Tubes Or Cuvettes With Automatic System That Washes And Drys The Cuvettes Used. It Must Have A Sensor On The Sample/Reagent Pipettor Needle, Which Indicates With An Audible And On-Screen Alert, In The Event Of A Lack Of Samples Or A Lack Of Reagents. It Must Accept Emergency Samples So That, Even When There Is A Routine In Progress, It Allows Interface With The Laboratorys Operational Software, Using The Internal Bar Code Reader For Samples. Have Wave Filters With At Least 10 Different Wavelengths, Which Are Mandatory Cover The Range Between 340 And 800 Nm Open System With The Possibility For The User To Define The Working Profile, For Any Brand Of Reagents On The Market, With Capacity For At Least 100 Programs, Or More, Of Different Techniques (Reagents) Simultaneously Accessories: Cpu (Operating Computer) Monitormouse And Keyboard Suitable For The Model. Current Registration With Anvisa/Ms., Ion/Electrolyte Analyzer Ion Analyzer With Minimum Of 04 Parameters: Na+, K+ Cl- Ca+2 With Reading Of Whole Blood, Serum, Plasma Or Urine And With Sample Volume Of 150 Iul Or Less. Perform At Least 60 Analyzes Per Hour. With Automatic Calibration, Alphanumeric Display, Thermal Printer And Rs232c Serial Port. Electrical Power Supply To Be Defined By The Requesting Entity. Have Registration With Anvisa/Ms, Laboratory Microscopy Binocular Phase Contrast Laboratory Microscopy. Icom Observation Tube At Minimum 160 Mm Length With Binocular Head Tilted At 30 And Rotation I360 Degrees, With Interpupillary Distance Adjustment And Diopter Adjustment To
Key Value
Tender Value
257,812 - BRL
Tender Documents
Global Tender Document
bfda191a-1093-4230-b77f-ad6b7e162ea2.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.