GTR 111662181
Request For Quotation Purchasing Medical Products For Laboratories
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
111662181
Tendering Authority
Subscribe to view
Tender No
16777258
Financer Name
Self-Funded
Work Title
Request For Quotation Purchasing Medical Products For Laboratories
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
15-04-2026
Closed
Work Detail
Biochemical Control Level I Set Of Biochemical Reagents From The Kit Biochemical-Turbidimetric Analyzer Bts-350, Parameters: Ace, Acid Phosphatase, Albumin, Alkaline Phosphatase, Alt, Ast, A-Amylase, Β-Hydroxybutyrate, Total And Direct Bilirubin, Total Bile Acids, Calcium, Chlorides, Cholesterol, Hdl-Cholesterol, Sc, Creatinine, Glucose, Ggt, Iron, Ldh, Lactate, Lipase, Magnesium, Phosphorus, Potassium, Total Protein, Sodium, Triglycerides, Urea, Uric Acid, Zinc, Packaging 5 X 5 Ml, T +2 +8 C, Test Strips Uriscan 11 For Conducting Biochemical Studies Of Urine For 11 Parameters (Blood, Bilirubin, Urobilinogen, Ketones, Protein, Nitrites, Glucose, Ph, S/G, Leukocytes, Ascorbic Acid) On A Semi-Automatic Urine Analyzer Uriscan Optima, Supplied In A Tube (100 Pcs/Pack) Packed In A Cardboard Box, Storage Temperature +2 +30 C, Ready-To-Use Reagent For Lysing Red Blood Cells And For Accurate White Blood Cell Counting, Trimodal Size Distribution Analysis Of White Blood Cells (Lymphocytes, Neutrophils And Mixed Cell Population) And Hemoglobin Level Measurement. Contains Ammonium Salts And Sodium Chloride. Packaging 3 Bottles Of 500 Ml. Designed For Use In Sysmex Hematology Analyzers, Reagent For Determining Thrombin Time In Human Citrated Plasma. The Test Is Usually Performed To Diagnose Inherited Fibrinogen Deficiency Or Defects And To Rule Out Heparin Contamination. The Time Of Clot Formation In The Test Sample Is Measured When Fibrinogen Is Converted Into Fibrin After Adding Purified Bovine Thrombin To The Plasma. Release Form: Lyophilisate. Determination Methods: Nephelometry Or Turbidimetry. Supplied In Cardboard Packages (Pack: 4 Bottles Of 8 Ml Of Reagent + 1 Bottle Of 9 Ml Of Diluent). Storage Temperature +2 +8 C. Packing: 4 Bottles. 8 Ml Of Reagent + 1 Vial. 9 Ml Of Diluent. Determination Methods: Nephelometry Or Turbidimetry. Used To Work On The “Closed” System Of Analyzers Of The Acl Top (300, 500, 700) And Acl Elite Pro Family, Cellpack (Diluent Used To Dilute Aspirated Samples For Analysis To Measure Red Blood Cell Count, White Blood Cell Count, Hemoglobin Concentration And Platelet Count, Conductivity Not More Than 13.40 Ms/Cm, Ph In The Range Of 7.75-7.85, Packaging Volume - 20 L), Bilirubin (Direct) Set Of Biochemical Reagents From The Set Biochemical-Turbidimetric Analyzer Bts-350. Liver Profile; Diazosulfonilic Acid Endpoint; Liquid Bireagent, Number Of Studies -600 (For Automatic Systems), Packaging 4X50ml, T+15 +30 C, Reagent For The Determination Of Fibrinogen According To Clauss In Human Citrated Plasma. The Reagent Contains Purified Bovine Thrombin At A Concentration Of 100 U/Ml. The Linearity Of The Method Is 35-1000 Mg/Dl. The Reagent Is Not Sensitive To Direct Thrombin Inhibitors. Release Form: Lyophilisate. Determination Methods: Nephelometry Or Turbidimetry. Supplied In Cardboard Packages (Pack: 10 Bottles Of 5 Ml Of Reagent). Storage Temperature +2 +8 C. Packing: 10 Fl. 5 Ml Of Reagent. Determination Methods: Nephelometry Or Turbidimetry. Used To Work On The “Closed” System Of Analyzers Of The Acl Top (300, 500, 700) And Acl Elite Pro Family, Glass Pencils, Length 63, Diameter 8, Biochemical Calibrator Set Of Biochemical Reagents From The Kit Biochemical-Turbidimetric Analyzer Bts-350, Parameters: Ace, Acid Phosphatase, Albumin, Alkaline Phosphatase, Alt, Ast, A-Amylase, Β-Hydroxybutyrate, Total And Direct Bilirubin, Total Bile Acids, Calcium, Chlorides, Cholesterol, Hdl-Cholesterol, Sc, Creatinine, Glucose, Ggt, Iron, Ldh, Lactate, Lipase, Magnesium, Phosphorus, Potassium, Total Protein, Sodium, Triglycerides, Urea, Uric Acid, Zinc, Packaging 5X5 Ml, T +2 +8 C, Iron (Ferrozine) Set Of Biochemical Reagents From The Set Biochemical-Turbidimetric Analyzer Bts-350, Diagnosis Of Anemia; Ferrozine, Endpoint; Liquid Bireagent, Number Of Studies -600 (For Automatic Systems), Packaging 4X50ml, T +2 +8 C, Plasma Diluent. Designed To Dilute Plasma During Research. Release Form: Liquid, Ready For Use. Determination Method: Nephelometry Or Turbidimetry. In Cardboard Packages (Pack: 1 Bottle Of 100 Ml). Storage Temperature +15 +25 C., Bilirubin (General) Set Of Biochemical Reagents From The Set Biochemical-Turbidimetric Analyzer Bts-350. Liver Profile; Diazosulfonilic Acid Endpoint; Liquid Bireagent, Number Of Studies -600 (For Automatic Systems), Packaging 4X50ml, T +15 +30 C, Reagent For Determining Activated Partial Thrombin Time (Aptt) In Human Citrated Plasma. The Aptt Method Is Used As The Primary Screening Method For Assessing Intrinsic Coagulation Pathway Disorders And For Monitoring Heparin Anticoagulant Therapy. The Method Is Sensitive To Reduced Concentrations Of Contact Phase Factors, Intrinsic And Common Coagulation Pathway Factors, The Anticoagulant Effect Of Heparin And The Presence Of Inhibitors, In Particular Lupus-Like Anticoagulants. Recommended For Use For Preoperative Screening Diagnostics. Release Form: Liquid, Ready For Use. Determination Methods: Nephelometry Or Turbidimetry. (Pack: 5 Bottles Of 10 Ml Of Reagent + 5 Bottles Of 10 Ml Of Calcium Chloride). Storage Temperature +2 +8 C. Packing: 5 Fl. 10 Ml Of Reagent + 5 Fl. 10 Ml Of Calcium Chloride. Determination Methods: Nephelometry Or Turbidimetry. Used To Work On The “Closed” System Of Analyzers Of The Acl Top (300, 500, 700) And Acl Elite Pro Family, Safe Lancet, With A Puncture Depth Of 2.25 Mm, 23G No. 100, Control Blood (High Level) To Test The Precision And Accuracy Of Hematology Analyzers For 16 Diagnostic And 6 Service Parameters., Biochemical Control Level Ii Set Of Biochemical Reagents From The Kit Biochemical-Turbidimetric Analyzer Ba400, Parameters: Ace, Acid Phosphatase, Albumin, Alkaline Phosphatase, Alt, Ast, A-Amylase, Β-Hydroxybutyrate, Total And Direct Bilirubin, Total Bile Acids, Calcium, Chlorides, Cholesterol, Hdl-Cholesterol, Sc, Creatinine, Glucose, Ggt, Iron, Ldh, Lactate, Lipase, Magnesium, Phosphorus, Potassium, Total Protein, Sodium, Triglycerides, Urea, Uric Acid, Zinc, Packaging 5X5 Ml, T +2 +8 C, Cleaning Solution. Designed For Daily Cleaning Of Coagulometers. The Kit Contains: Hydrochloric Acid. Release Form: Liquid, Ready For Use. In Cardboard Packages (Pack: 1 Bottle Of 500 Ml). Storage Temperature +15 +25 C., Control Blood (Low Level) To Check The Precision And Accuracy Of Hematology Analyzers For 16 Diagnostic And 6 Service Parameters, Cellclean (Strongly Alkaline Cleaner, 50 Ml Volume, For Removing Lysis Reagents, Cellular Debris And Blood Proteins From The Hydraulic System Of The Device. Designed For Use In Sysmex Hematology Analyzers), Reagent For The Determination Of Prothrombin Time (Pt), Inr And Estimated Fibrinogen In Human Citrated Plasma. Used To Evaluate The Extrinsic Hemostatic Pathway And Monitor Oat. The Reagent Contains Recombinant Human Tissue Factor, Characterized By Mic ~ 1. The Reagent Is Stable On Board The Analyzer For 10 Days. Release Form: Liquid (Ready To Use). Packing: 5 Fl. 20 Ml Of Reagent. Determination Methods: Nephelometry Or Turbidimetry. Used To Work On The “Closed” System Of Analyzers Of The Acl Top (300, 500, 700) And Acl Elite Pro Family
Key Value
Tender Value
3,718,583 - KZT
Tender Documents
Global Tender Document
5c76c315-0508-467f-865d-3426f013fa60.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.