Tenders Are Invited For Reagents And Consumables For The Modular Analyzer Cobas Pro (E 802) And Cobas Pure (E 402)

Tender Detail

111605945
16757024
Self-Funded
Tenders Are Invited For Reagents And Consumables For The Modular Analyzer Cobas Pro (E 802) And Cobas Pure (E 402)
NCB
Central Asia
Commonwealth of Independent States, CIS
21-04-2026

Work Detail

Thyroid Peroxidase Antibody Cassette - Elecsys Anti-Tpo 300 Tests. Reagents For The Cobas Pro/Pure Analyzer.. Cassette Antibodies To Thyroid Peroxidase - Elecsys Anti-Tpo 300 Tests. Cassette For Determining Antibodies To Thyroid Peroxidase - Anti-Tpo For Cobas Pro Analyzer For 300 Determinations Purpose: Anti‑Tpo Calset Used To Calibrate A Quantitative Test Elecsys Anti‑Tpo On Immunochemical Analyzers Elecsys And Cobas Pro. Anti-Tpo Calset Is A Lyophilized Human Serum Matrix With Added Anti-Thyroid Peroxidase (Anti-Tpo) Antibodies In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Level 1 Calibrator Anti‑Tpo Cal1: 2 Bottles, Each For Preparing 1.5 Ml Of Calibrator 1 ▪ Level 2 Calibrator Anti‑Tpo Cal2: 2 Bottles, Each For Preparing 1.5 Ml Of Calibrator 2. To Prepare The Calibrator, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C 8 Weeks, At 2‑8 °C Up To 8 Hours. Measuring Range 9‑600 Iu/Ml. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., C-Peptide Cassette - Elecsys C-Peptide 100 Tests. Reagents For The Cobas Pro/Pure Analyzer.. C-Peptide Cassette - Elecsys C-Peptide 100 Tests. Purpose: Immunotest For In Vitro Diagnostics. Designed For The Quantitative Determination Of C‑Peptide In Human Urine, Serum And Plasma. The Eclia Electrochemiluminescent Immunoassay Is Intended For Use On Cobas E Immunochemical Analyzers. Reagents - Working Solutions: The Reagent Cassette Is Labeled Cpeptid. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-C-Peptide-Ab~Biotin (Gray Cap), 1 Bottle, 9 Ml: Biotinylated Monoclonal Antibody (Mouse) To C-Peptide 1 Mg/L; Phosphate Buffer 50 Mmol/L, Ph 6.0; Preservative R2 Anti-C-Peptide-Ab~Ru(Bpy) (Black Cap), 1 Bottle, 9 Ml: Monoclonal Antibody (Mouse) To C-Peptide, Labeled With Ruthenium Complex, 0.4 Mg/L; Phosphate Buffer 50 Mmol/L, Ph 6.0; Preservative The Reagents Are Ready For Use, Supplied In A Cassette And Not Must Be Separated. *Wounding And Stability: *Wound At 2‑8 °C. Do Not Freeze. Stable, Unopened, At 2‑8°C Until The Stated Expiration Date, After Opening At 2‑8 °C 12 Weeks On Board Analyzers 8 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Troponin I Cassette - Elecsys Troponin I 300 Tests (According To Technical Specification), Cassette For Quantitative Determination Of The Sum Of Human Chorionic Gonadotropin (Hcg) And Hcg Beta Subunit - Elecsys Hcg+Beta 300 Tests. Reagents For The Cobas Pro/Pure Analyzer. Elecsys Hcg+Beta 300 Test Cassette. Purpose: In Vitro Test For The Quantitative Determination Of The Amount Of Human Chorionic Gonadotropin (Hcg) And Hcg Β-Subunit In Human Serum And Plasma. The Eclia Electrochemiluminescent Immunoassay Is Intended For Use On Cobas E Immunochemical Analyzers. Reagents - Working Solutions: This Basic Reagent Kit Is Labeled Hcg‑Beta. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-Hcg-Ab~Biotin (Gray Cap), 1 Bottle, 9 Ml: Biotinylated Monoclonal Anti-Hcg Antibodies (Mouse) 2.6 Mg/L; Phosphate Buffer 40 Mmol/L, Ph 7.5; Preservative R2 Anti-Hcg-Ab~Ru(Bpy) (Black Cap), 1 Bottle, 10 Ml: Monoclonal Anti-Hcg Antibody (Mouse) 4.6 Mg/L; Phosphate Buffer 40 Mmol/L, Ph 6.5; Preservative The Reagents Are Ready For Use, Supplied In A Cassette And Not Must Be Separated. Storage And Stability: Store At 2‑8 °C. Do Not Freeze. Stability: Unopened At 2‑8 °C Until The Expiration Date Indicated, Open At 2‑8 °C 12 Weeks, On Board Analyzers 4 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette Total Antibodies To Viral Hepatitis C - Elecsys Anti-Hcv Ii 300 Tests. (According To Technical Specification), Free Thyroxine Cassette - Elecsys Ft4 Ii 300 Tests. Reagents For The Cobas Pro/Pure Analyzer. Free Thyroxine Cassette - Elecsys Ft4 Ii 300 Tests. Purpose: Immunotest For In Vitro Diagnostics. Designed For Quantitative Determination Of Free Thyroxine In Human Serum And Plasma. The Eclia Electrochemiluminescent Immunoassay Is Intended For Use On Elecsys And Cobas E Immunochemical Analyzers. Reagents - Working Solutions: The Reagent Cassette Is Labeled Ft4 Iii. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 12 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-T4-Ab~Ru(Bpy) (Gray Cap), 1 Vial, 18 Ml: Polyclonal Anti-T4 Antibody (Sheep) Labeled With Ruthenium Complex, 75 Ng/Ml; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative R2 T4~Biotin (Black Cap), 1 Bottle, 18 Ml: Biotinylated T4 2.5 Ng/Ml; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative The Reagents Are Ready For Use, Supplied In A Cassette And Should Not Be Separated. *Injury And Stability: *Injure At 2‑8 °C. Do Not Freeze. Stability: Unopened At 2‑8 °C Until The Expiration Date Indicated, Unopened At 2‑8 °C 84 Days, On Board Analyzers 56 Days. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Insulin Cassette - Elecsys Insulin 100 Tests. Reagents For The Cobas Pro/Pure Analyzer.. Insulin Cassette - Elecsys Insulin 100 Tests. Purpose: Immunotest For In Vitro Diagnostics. Designed For The Quantitative Determination Of Human Insulin In Human Serum And Plasma. The Determination Of Insulin Is Used To Diagnose And Monitor The Treatment Of Various Disorders Of Carbohydrate Metabolism, Including Diabetes Mellitus And Hypoglycemia. The Eclia Electrochemiluminescent Immunoassay Is Intended For Use On Cobas E Immunochemical Analyzers. Reagents - Working Solutions: The Insulin Label Is Affixed To The Package Containing The Basic Reagents. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-Insulin-Ab~Biotin (Gray Cap), 1 Bottle, 10 Ml: Biotinylated Monoclonal Antibody To Insulin (Mouse), 1 Mg/L; Mesb) Buffer 50 Mmol/L, Ph 6.0; Preservative R2 Anti-Insulin-Ab~Ru(Bpy) (Black Cap), 1 Bottle, 10 Ml: Monoclonal Antibody To Insulin (Mouse), Labeled With Ruthenium Complex, 1.75 Mg/L; Mes Buffer 50 Mmol/L, Ph 6.0; Preservative The Reagents Are Ready For Use, Supplied In A Cassette And Not Must Be Separated. Storage And Stability: Store At 2‑8 °C. Do Not Freeze. Stability: Unopened At 2‑8 °C Until The Expiration Date Indicated, Open At 2‑8 °C 12 Weeks, On Board Analyzers 4 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette Triiodothyronine Free - Elecsys Ft3 Iii 300 Tests. Reagents For The Cobas Pro/Pure Analyzer.. Cassette Free Triiodothyronine - Elecsys Ft3 Iii 300 Tests. Purpose: Immunotest For In Vitro Diagnostics. Designed For Quantitative Determination Of Free Triiodothyronine Content In Human Serum And Plasma. The Eclia Electrochemiluminescent Immunoassay Is Intended For Use On Elecsys And Cobas E Immunochemical Analyzers. Reagents - Working Solutions: The Package Containing The Basic Reagents Is Labeled Ft3 Iii. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 12 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti‑T3‑Antibody~Ru(Bpy) (Gray Cap), 1 Vial, 18 Ml: Monoclonal Anti‑T3‑Antibody (Sheep), Labeled With Ruthenium Complex 18 Ng/Ml; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative R2 T3~Biotin (Black Cap), 1 Bottle, 18 Ml: Biotinylated T3 2.4 Ng/Ml; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative The Reagents Are Ready For Use, Supplied In A Cassette And Should Not Be Separated. Storage And Stability: Store At 2‑8 °C. Do Not Freeze. Stability: Unopened At 2‑8°C Until Expiration Date, Unopened At 2‑8°C 84 Days (12 Weeks), On Board Analyzer 42 Days (6 Weeks). If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette For Quantitative Determination Of Biointact Parathyroid Hormone - Elecsys Pth 300 Tests. Reagents For The Cobas Pro/Pure Analyzer.. Elecsys Pth 300 Test Cassette Purpose: Immunotest For In Vitro Diagnostics. Designed For The Quantitative Determination Of Intact Parathyroid Hormone In Human Serum And Plasma For The Differential Diagnosis Of Hypercalcemia And Hypocalcemia. The Eclia Electrochemiluminescent Immunoassay Is Intended For Use On Cobas E Immunochemical Analyzers. Reagents - Working Solutions: The Pth Label Is Affixed To The Package With The Main Reagents. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Microparticles Coated With Streptavidin, 0.72 Mg/Ml; Preservative R1 Anti-Pth Antibody~Biotin (Gray Cap), 1 Vial, 7 Ml: Biotinylated Monoclonal Anti-Pth Antibody (Mouse) 2.3 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative R2 Anti-Pth Antibody~Ru(Bpy) (Black Cap), 1 Bottle, 7 Ml: Monoclonal Anti-Pth Antibodies (Mouse), Labeled With Ruthenium Complex 2.0 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative The Reagents Are Ready For Use, Supplied In A Cassette And Should Not Be Separated. Storage And Stability: Store At 2‑8 °C. Do Not Freeze. Stability: Unopened At 2‑8 °C Until The End Of The Shelf Life, Unopened At 2‑8 °C 12 Weeks, On Board The Analyzer 8 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Natriuretic Peptide Cassette - Elecsys Probnp Ii, 300 Tests. Immunotest For In Vitro Diagnostics. Designed For The Quantitative Determination Of The N-Terminal Fragment Of Pro Natriuretic Peptide Type B (Nt-Probnp) In Human Serum And Plasma. This Test Is Used As An Auxiliary Diagnostic Method In Patients With Suspected Chronic Heart Failure And To Identify Mild Forms Of Cardiac Dysfunction., Folate Cassette - Elecsys Folate 300 Tests. Reagents For The Cobas Pro/Pure Analyzer. Folate Cassette - Elecsys Folate 300 Tests. Purpose: Test For In Vitro Diagnostics. Designed For Quantitative Determination Of Bound Folate In Human Serum And Plasma. This Test Is Intended For Use On Cobas E Immunochemical Analyzers. Reagents - Working Solutions: The Main Reagent Cassette (M, R1, R2) And Pre-Treatment Reagents (Pt1, Pt2) Are Labeled Fol Iii. Pt1 Pre-Treatment Reagent 1 (White Cap), 1 Bottle, 4 Ml: Sodium 2-Mercaptoethanesulfonate (Mesna) 40 G/L, Ph 5.5. Pt2 Pre-Treatment Reagent 2 (Gray Cap), 1 Bottle, 5 Ml: Sodium Hydroxide 25 G/L. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Folate-Binding Protein~Ru(Bpy) (Gray Cap), 1 Vial, 9 Ml: Ru-Labeled Folate-Binding Protein, 75 Μg/L; Human Serum Albumin (Stabilizer); Borate/Phosphate/Citrate Buffer 70 Mmol/L, Ph 5.5; Preservative R2 Folate~Biotin (Black Cap), 1 Bottle, 8 Ml: Biotinylated Folate 17 Μg/L; Biotin 120 Μg/L; Human Serum Albumin (Stabilizer); Borate Buffer 100 Mmol/L, Ph 9.0; Preservative The Reagents Are Ready For Use, Supplied In A Cassette And Should Not Be Separated. Storage And Stability: Store At 2‑8 °C. Do Not Freeze. Stability: Unopened At 2‑8 °C Until Expiration Date Indicated, Unopened At 2‑8 °C 56 Days (8 Weeks), On Board Analyzers 14 Days. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette Thyroid-Stimulating Hormone - Elecsys Tsh 300 Tests. Reagents For The Cobas Pro/Pure Analyzer.. Thyroid-Stimulating Hormone Cassette - Elecsys Tsh 300 Tests. Purpose: Immunotest For In Vitro Diagnostics For Quantitative Determination Thyroid-Stimulating Hormone (Tsh) In Human Serum And Plasma. Electrochemiluminescent Immunotest Eclia Is Intended For Use On Immunochemical Analyzers Cobas E. Reagents - Working Solutions: The Tsh Label Is Affixed To The Package With The Main Reagents. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 12 Ml: Streptavidin-Coated Microparticles 0.72 Mg/Ml; Preservative R1 Anti-Tsh-Ab~Biotin (Gray Cap), 1 Bottle, 14 Ml: Biotinylated Anti-Tsh Monoclonal Antibodies (Mouse) 2.0 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.2; Preservative R2 Anti-Tsh-Ab~Ru(Bpy) (Black Cap), 1 Bottle, 12 Ml: Monoclonal Anti-Tsh Antibodies (Mouse/Human), Labeled With Ruthenium Complex 1.5 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.2; Preservative The Reagents Are Ready For Use, Supplied In A Cassette And Not Must Be Separated. Storage And Stability: Store At 2‑8 °C. Do Not Freeze. Stability: Unopened At 2‑8 °C Until Expiration Date Shelf Life, After Opening At 2‑8 °C 12 Weeks, On Board Cobas E 601 And Cobas E 602 6 Weeks, On Board Cobas E 411 8 Weeks. . If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Vitamin B12 Cassette - Elecsys Vitamin B12 Ii For 300 Tests. Reagents For The Cobas Pro/Pure Analyzer.. Vitamin B12 Cassette - Elecsys Active B12 300 Tests. Purpose: Binding Assay For In Vitro Quantification Of Levels Vitamin B12 In Human Serum And Plasma. Electrochemiluminescent Immunotest Eclia Is Intended For Use On Cobas E Immunochemical Analyzers. Reagents - Working Solutions: The Main Reagent Package (M, R1, R2) And Pre-Treatment Reagents (Pt1, Pt2) Are Labeled B12 Ii. Pt1 Pre-Treatment Reagent 1 (White Cap), 1 Bottle, 4 Ml: Dithiothreitol 1.028 G/L; Stabilizer, Ph 5.5. Pt2 Pre-Treatment Reagent 2 (Grey Cap), 1 Bottle, 4 Ml: Sodium Hydroxide 40 G/L; Sodium Cyanide 2.205 G/L. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Intrinsic Factor~Ru(Bpy) (Grey Cap), 1 Vial, 10 Ml: Recombinant Porcine Intrinsic Factor, Ruthenium Labeled, 4 Μg/L; Cobinamide Dicyanide 15 Μg/L; Stabilizer; Human Serum Albumin; Phosphate Buffer, Ph 5.5; Preservative R2 Vitamin B12~Biotin (Black Cap), 1 Bottle, 8.5 Ml: Biotinylated Vitamin B12 25 Μg/L; Biotin 3 Μg/L; Phosphate Buffer, Ph 7.0; Preservative The Reagents Are Ready For Use, Supplied In A Cassette And Should Not Be Separated. Storage And Stability: Store At 2‑8 °C. Do Not Freeze. Stability: Unopened At 2‑8 °C Until Expiration Date, After Opening At 2‑8 °C 84 Days (12 Weeks), On Board The Analyzer 35 Days (5 Weeks). If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Ferritin Cassette - Elecsys Ferritin 300 Tests. Reagents For The Cobas Pro/Pure Analyzer. Ferritin Cassette - Elecsys Ferritin 300 Tests. Purpose: Immunotest For In Vitro Diagnostics. Designed For The Quantitative Determination Of Ferritin In Human Serum And Plasma. Electrochemiluminescent Immunoassay Eclia Is Intended For Use On Immunochemical Analyzers Cobas E. Reagents - Working Solutions: The Reagent Cassette Is Labeled Ferr. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti‑Ferritin‑At~Biotin (Gray Cap), 1 Bottle, 10 Ml: Biotinylated Monoclonal Antibody To Ferritin (Mouse) 3.0 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.2; Preservative R2 Anti-Ferritin-At~Ru(Bpy) (Black Cap), 1 Bottle, 10 Ml: Monoclonal Antibody To Ferritin (Mouse), Labeled With Ruthenium Complex, 6.0 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.2; Preservative The Reagents Are Ready For Use, Supplied In A Cassette And Not Must Be Separated. Storage And Stability: Store At 2‑8 °C. Do Not Freeze. Stability: Unopened At 2‑8 °C Until The Expiration Date Indicated, After Opening At 2‑8 °C 12 Weeks, On Board Analyzers 6 Weeks. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database., Cassette For Qualitative In Vitro Determination Of Hepatitis B Surface Antigen (Hbsag) - Elecsys Hbsag Ii 300 Tests. (According To Technical Specification), Procalcitonin Cassette - Elecsys Brahms Pct 300 Tests. (According To Technical Specification)

Key Value

Tender Value
1,63,61,540 - KZT

Attachment

FileName File Description
Global Tender Document e78fc935-b67e-4e3e-bcbf-cde2406719e0.html
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail

WhatsApp