Ups Ups - Power: 3 Kva Input Voltage: 220V Type: On-Line Double Conversion 1.Nobreak (Ups) Online Double Conversion;2.Have Pure Sine Waveform;3.Have Power Of 3000Va;4.Have Output Power Factor Of 0.9;5.Have Nominal Input Voltage 220 Vac; Overvoltage;12.Have Overload Protection;13.Have Inverter Short-Circuit Protection;14.Have Autonomy Of 30 Minutes Under Half Load;15.Enable Cold Start – Can Be Started Even In The Absence Of The Electrical Network With A Charged Battery;16.Have Sealed Batteries For Use In Nobreaks;17.Allow Autonomy Expansion;18.Have 04 10A Sockets Standard Nbr 14136;19.Have Display Or Leds For Information About Energy, Battery And Charge;20.Have Internal Stabilizer;21.Have Automatic Battery Recharging;22.Have Power Supply With Cable 1M, With Tripolar Plug, According To Nbr 14136;23.Operating Temperature: 0ºc To 40ºc;24.Maximum Weight Of 30Kg, Ups Ups - Power 3.5 Kva Input Voltage: 220V Type: Sinusoidal Single-Phase Ups 3.5Kva 220V1. Technology: On-Line Double Conversion, According To Nbr 15014;2. Power: 3.5Kva (At Minimum);3. Output Power Factor: 0.99;4. Nominal Input Voltage: From 220V To 230V~(Fn);5. Input Frequency: 60Hz;6. Nominal Output Voltage: From 220V To 230V~(Fn);7. Output Frequency: 60Hz +- 0.05%;8. Pure Sine Waveform At Output;9. Output Static Regulation: +/-2%;10. Crest Factor: 3:1;11. Minimum Number Of Sockets: 4 (Four), At Least 2 (Two) For 20A (Nbr14136);12. Minimum Autonomy Of 30 Minutes Under Half Load;13. Batteries: Vrla 12V;14. Internal Batteries To The Cabinet;15. Have Network Management;16. Metal Cabinet For Floor Mounting;17. Ip20;18 Protection. Forced Ventilation System: Fan/Exhaust Fan;19. Acoustic Noise One Meter Away ≪ 60 Db (Din 45635);20. Linear Correction Of Variation In The Electric Network;21. Visual Signaling For Power Supply Mode (Mains Or Battery);22. End Of Battery Charge Indication;23. Protection Against Total Battery Discharge;24. Compatible With Generator Group;25. Automatic By-Pass System In Case Of Failure;26. Automatic Reconnection (Return From The Network With A Discharged Battery);27. Protection Against Short Circuit, Undervoltage And Overvoltage At The Output;28. Protection Against Harmonic Distortion Of The Electric Network, Voltage Sag (Sag) And Variation In Frequency Of The Electric Network;29. Support Inverter Overload Of 125% For 10 (Ten) Seconds;30. Connections And Electrical Interconnection Cables Included;31. Technical Manual With Installation, Use, Conservation And Maintenance Instructions. Notes:1) In Addition To The Proposal, The Bidder Must Indicate, Item By Item, The Document And Page Where Proof Of Compliance With Each Requirement And Conformity Of The Proposed Material With The Specification Required In These Terms.2) Exceptions Will Be Evaluated Upon Request Accompanied By Technical Justification. Ps: Delivery Location S, Monitor Monitor - Screen: 34 Type: Ips Or Oled Format: Widescreen Power: Bivolt 34-Inch Monitors In “Ultrawide” Standard And With 1440P Resolution (3440X1440 Pixels)., 09/04/2026 - 11:20:29, 09/04/2026 - 11:20:30, 09/04/2026 -
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.