GTR 111575749

Request For Quotation Medical Sciences (Endoscopy)

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
111575749
Tendering Authority
Subscribe to view
Tender No
16764772
Financer Name
Self-Funded
Work Title
Request For Quotation Medical Sciences (Endoscopy)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
13-04-2026 Closed
Work Detail
Endoscope Channel Cleaning Brushes Should Effectively Clean All Channels From 2.8 Mm To 5 Mm In Diameter In No More Than One Stroke. The Working Length Of The Brush Is At Least 2200 Mm. The Working Part Of The Brush Must Be Made Of Silicone And Not Damage The Walls Of The Endoscope Channels. The Working Part Of The Brush Should Consist Of 5 Silicone Rings, Which Should Ensure Full Contact With The Walls Of The Endoscope Channels And Create A Vacuum, Which In Turn Should Ensure Complete Filling Of The Endoscope Channels With The Cleaning Solution. To Remove Organic Contaminants, Brushes Must Provide “Piston” Cleaning. Brushes Must Be Fully Compatible With Endoscopic Equipment: Olympus, Pentax, Fujinon, Karl Storz., The Conductor Is Disposable. Conductor Diameter 0.035. Conductor Length No More Than 4300 Mm., Injection Tube (Irrigator For All Channels). Compatible With Evis 140/160/240/Oes-40/Oes-40 And Gf-Uc140p-Al5, Gf-Uct 140-Al5, Gf-Uc160p-Ol5, Gf-Uct160-Ol5, Gf-Uc140p-Do5, Gf. -Uct140-Do5 And Gf-Um160., Cylinder For Stone Extraction. Disposable Three-Lumen Cylinder For Stone Extraction. Possibility Of Working With Endoscopes With A Channel Of 2.8 Mm Or More, Length 1900 Mm, Maximum Balloon Diameter 15 Mm. The Presence Of 3 Separate Ports For The Introduction Of Liquids, A Conductor And For Connection To An Inflating Syringe With A Luer-Lock Connector. The Presence Of A Shut-Off Valve To Control The Air Flow. The Injection Hole Is Located Above The Balloon. The Kit Includes 3 Syringes Of Different Sizes, Providing Balloon Inflation To Sizes 8.5, 11.5 And 15.0 Mm. Presence Of A Radiopaque Tip. Compatible With 0.035 Guidewire. Features An Integrated Handle With A C-Shaped Holder. Compatible With The Olympus V-Holder. Instrument Is Sterile., Thermal Paper For Ecg 6-Channel Device. Paper For 6-Channel Ecg Device Nihon Kohden Fqw 210-3-140, Size 210*40*200 Cm, Connection Set For (Flexible Tubes For Water Inlet And Outlet). Devices For Cleaning Endoscopes Scope Buddy. The Kit Should Consist Of Silicone Tubes Of Different Lengths. The Kit Should Include A Water Intake Tube With A Round Metal Mesh, A Set Of Tubes For Connecting To The Endoscope Channels For 2 Leads, 3 Leads And 4 Leads. Also, An Extension Tube For One Of The Supply Lines And A Tube For Connecting To The Luer Channel., Disposable Electrosurgical Knife With A Triangular Tip And A Built-In Fluid Supply Channel. Compatible With 2.8Mm Instrument Channel. Tool Length From 1500 To 1700 Mm. Length Of Retractable Cutting Part From 2.0 To 4.5 Mm. The Distal End Of The Cutting Part Is Button-Shaped. Button Diameter From 0.3 To 0.4 Mm. Possibility Of Two-Stage Adjustment Of Knife Length. Plastic Covering Of The Insertion Part. Connector For Connection To The Electrosurgical Unit. Connector For Fluid Injection. Channel For Introducing Fluid. The Length Of The Protruding Part With The Knife Closed Is 0.1. Possibility Of Connection To A Flushing Pump. Sterility., Dilatation Balloon. Inflator Compatible. Compatible With 2.8Mm Instrument Channel. Tool Length From 2300 To 2500 Mm. Cylinder Length From 60 To 70 Mm. Balloon Diameter From 7.0 To 11.0 Mm. Possible Pressure Generated Is From 1.0 To 10.0 Bar. Consecutive Inflation Of The Balloon To 3 Sizes. Central Visual Marker. Rounded Ends Of Dilatation Balloon. Port For Introducing A Conductor With A Luer-Lock Connector. Inflator Port With Luer-Lock Connector. X-Ray Contrast Marks In The Distal Part At Least 2 Pieces. Compatible 0.035 Guidewire. Pre-Installed Guidewire. Sterile., Disposable Cannula With Standard Tip. Compatible With An Instrument Channel Of At Least 2.2 Mm. Tool Length Is At Least 1950 Mm. Distal Diameter 4 Fr. Straight Type Tip. Port For Introducing Contrast And Conductor With Luer-Lock Connector. X-Ray Contrast Marks In The Distal Part At Least 3 Pieces. Compatible With Minimum 0.035 Inch Conductor. Integrated Handle With C-Shaped Holder. Sterility., Disposable Electrosurgical Knife With Insulated Tip - For The Esophagus And Colon. Electrosurgical Knife, Channel 2.8 Mm, Length 2300 Mm., Coagraspers - Disposable Electrosurgical Hemostatic Forceps. To Support Endoscopic Submucosal Dissection With Fast And Reliable Hemostasis. Anti-Slip Design For Secure Grip On Bleeding Areas. Simplified Grip Coagulation Process Rotation Function.
Key Value
Tender Value
4,612,853 - KZT
Tender Documents
Global Tender Document
5414964d-5c29-4a1f-9f7c-40ccae06514d.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders