Operating Theater Devices And Instruments – Procurement Of The Type Surgical Devices And Instruments - Laparoscopes, Financial Use 2026. Pneumoperitoneum Needle (Verres) With Silicone Coating, For Safer, Faster Insertion Into The Peritoneal Cavity, Sterile Single Use With Audible And Visual Confirmation, Using Serum Without The Risk Of Co2 Leakage And Luer-Lock Connection. 120Mm,Pneumoperitoneum Needle (Verres) With Silicone Coating, For Safer, Faster Insertion Into The Peritoneal Cavity, Sterile Single Use With Audible And Visual Confirmation, Using Serum Without The Risk Of Co2 Leakage And Luer-Lock Connection. 150Mm,Hasson Type Trocar 5-12Mm For Minimal Trauma With A Sponge Stabilizer For Better Stability On The Abdominal Walls And A Non Latex Balloon With A Capacity Of 20Ml Air For Better Functionality.,Hasson Type Trocar 5-10Mm For Minimal Trauma With A Sponge Stabilizer For Better Stability On The Abdominal Walls And A Non Latex Balloon With A Capacity Of 20Ml Air For Better Functionality,Disposable Sterile 5-12Mm Diameter Direct Vision (Optical) Trocar With Non-Traumatic Flattened V-Scalpel Wings, High Penetrating Capacity With Dolphin Nose Abdominal Wall Penetration Guide Tip And Ergonomic Low Profile Handle For Smooth And Precisely Controlled Insertion For Easier Trocar Placement.,Trocar 5-12Mm With A Pistol-Shaped Handle With A Cutting Mechanism For Entering The Peritoneal Cavity Under Direct Vision For Increased Safety. It Has A Ridged Cannula For Stabilization Of 100 Μm, Beveled Tip And The Possibility Of Removing The Upper Part For Extracting The Preparation.,5/12Mm Diameter Hasson Open Technique Trocar With Blind End, 100Mm Long, Transparent Throughout And Low Profile.,Sterile 5Mm Diameter Single-Use Trocar With 4.14Mm Lancet Sharp Tip Double-Edged Stainless Steel Cutting Blade Conforming To Astm F899,Sterile 5Mm Diameter Single-Use Trocar With 4.14Mm Lancet Sharp Tip Double-Edged Stainless Steel Cutting Blade Conforming To Astm F899,Sterile 5-12Mm Diameter Single-Use Trocar With 9.32Mm Lancet Sharp Tip Double-Edged Stainless Steel Cutting Blade Conforming To Astm F899,Abdominal Trocar With Scalpel-Shaped Lance, 5/12Mm Diameter And 150Mm Length, Transparent Throughout And Low Profile. To Limit Smearing Of Camera And Tools, It Has Technology To Collect, Remove And Absorb Liquids From A Sponge Inside The Cannula Head.,Direct Vision Trocar For Tissue Suturing, 5/12Mm In Diameter And 100Mm In Length, With A Conical End Consisting Of Two Plastic Wings In A Peduncle Handle, Transparent Throughout.,Direct Vision Trocar For Tissue Suturing, 5Mm In Diameter And 100Mm In Length, With A Conical Tip Consisting Of Two Plastic Wings In A Pedunculated Handle, Transparent Throughout.,Abdominal Trocar With Scalpel-Shaped Lance, 5Mm Diameter And 100Mm Length, Transparent Throughout And Low Profile. To Limit Smearing Of Camera And Tools To Have Technology To Collect, Remove And Absorb Liquids From A Sponge Inside The Cannula Head.,Direct Vision Trocar For Tissue Suturing, 5/12Mm In Diameter And 100Mm In Length, With A Conical End Consisting Of Two Plastic Wings In A Peduncle Handle, Transparent Throughout.,Trocar With Cannula And Trocar, With Scalpel Cutting Lance, With Automatic Lance Protection Shield, With Integrated And Fully Detachable Low-Profile Transducer,Trocar With Cannula And Trocar, With Scalpel Cutting Lance, With Automatic Lance Protection Shield, With Built-In And Fully Detachable Low-Profile Transducer, And With Special Stabilization Of Alternating Angulation On