Request For Quotation Products For Instrumentation And Automation. Part-2

Tender Detail

111528590
16725690
Self-Funded
Request For Quotation Products For Instrumentation And Automation. Part-2
NCB
Central Asia
Commonwealth of Independent States, CIS
10-04-2026

Work Detail

Technical Pressure Gauge, Pressure Gauge Body Diameter 100Mm, Pressure Measurement Range From 0...1.6 Kgf/Cm2, Accuracy Class - 1.5, Connection Thread M20*1.5, Gost 2405-88 (Kipia, Tsmk), Temperature Sensor, Resistance Thermal Converter (-50... +500С) Aries Dts335m-Rt100.0,5.100.Mg.I [4] Output Signal 4...20 Ma, Gost 13384-93 (Kipia, Chpp-2), Thermostatic Device, Ac Supply Voltage ~90…264 V (Nominal 230 V) Housing Version Ш1, 96×96X53 Mm Ip54 Availability Of Built-In Power Supply For 24V Dc Sensors Indication Type: U2 Or U3 Output Type: Output 1 - P, Output 2 - P. Input Polling Time: No More Than 1 Second. Gost R 51522 Pid Control Of Measured Value Auto-Tuning Of The Pid Controller Ambient Temperature -40...+50°С Gost R 51522 (Kipia, K-3), Flow Regulator, Control Device Proportional – Integral R25.1.2M, For Technological Process Control / Proportional-Integral Regulating Device, Control Of Actuators Without Intermediate Devices. With A Built-In Indicator Of The Position Of The Working Body Of The Actuator. From 1 To 3 Differential Transformer Measuring Converters. Overall Dimensions Of The Block: No More Than 120 X 240 X 285 Mm; The Mass Of The Block Is No More Than 3.5 Kg. Year Of Manufacture Not Earlier Than 2018, Gost 14254-96 (Chp-2), Rotary Control Switch, Black, Without Backlight, Long Handle, 10 A, 3 Positions, 2No, Self-Resetting, Gost R 51324.1-2012 (Chp-2), Differential Pressure Sensor, Pressure Transducer For Measuring Differential Pressure From 2.5...6.3 Kpa Measuring Environment: Air, Steam Output Signal 4…20 Ma (2-Wire Circuit) Accuracy Class Up To 0.1%. The Ability To Reconfigure The Measurement Range And Other Parameters From The Front Panel Of The Sensor. The Presence Of A Hart Interface For Transmitting Information About The State Of The Device And Measured Parameters In Digital Form. Rs-485 Modbus Digital Output Or Hart Digital Signal. Measuring Range: From 2.5…6.3 Kpa Supply Voltage 12…36 V Dc Temperature Range Of The Measured Medium: –40…+100 °С. The Inter-Verification Interval Is 2 Years. The Sensor Must Be Included In The State Register Of Measuring Instruments Of The Republic Of Kazakhstan. Year Of Manufacture 2025. Free Initial Factory Verification. Main Range 0-100Kpa Polysensory Measuring Element Housing Protection Degree Ip67 Basic Error 0.05% Process Connection For Installation With Three-Way Valve Manifold Gost 22520-85 (Kipia, K-3), Analog Output Module Modification Mu110-224.8I, Number Of Outputs 8 Ao, Output Type 4…20 Ma, Power Supply Universal ~230 V/=24V Din Rail/Wall Mounting, Gost 30617-98 (Kipia, Tpp-2), Amplifier For Amplifying Ac Mismatch Signals, Type Upd3-01, Is Used In Advanced Automation, Instrumentation And Measuring Bridges. They Are Used As Components For Beeping Recorders Of The Ksd2 Type. Supply Voltage 220V Gost 20493-2001 (Kipia, Chp), Reversing Starter - Contact, Magnetic Starter Type Mkr-0-58 For An Electric Mechanism Of The Meo Type. Ucat 24-220V. Gost 2491-82 (Kipia, Chp), Differential Pressure Sensor Huba Control 692.99099, Pressure Sensors Type 692. Pressure Measuring Range 0 ... 25 Bar (Relative And Variable). Response Time <5Ms. System Pressure 12; 25; 50 Bar. Burst Pressure 1.5 X System Pressure. Stainless Steel 1.4305 (Aisi 303); Pvdf. Energy Consumption <20 Ma. Gost 22520-85 (Kipia, Tsmk), Technical Pressure Gauge, Pressure Gauge Body Diameter 100 Mm, Pressure Measurement Range From 0...1 Kgf/Cm2, Accuracy Class 1.5, Connection Thread M20*1.5, Gost 2405-88 (Kipia, Chpp, K-3, Tsmk), Differential Pressure Sensor, Differential Pressure Transducer With Indication, With An Output Signal Of 4...20 Ma, With A Set Range From 0... 100 Kpa, Maximum Upper Limit 100 Kpa, The Ability To Reconfigure The Measurement Range From The Front Panel Of The Sensor To A Lower Measurement Limit, Reconfiguration, Supply Voltage 15...36V, Accuracy Class Up To 0.1%, Calibration Interval - 2 Years. The Sensor Must Be Included In The State Register Of Measuring Instruments Of The Republic Of Kazakhstan. Year Of Manufacture 2025. Free Initial Factory Verification. Main Range 0-100Kpa Polysensory Measuring Element Housing Protection Degree Ip67 Basic Error 0.05% Connection To The Measured Process For Installation With A Three-Way Valve Block, Connection To The Converter Internal M20*1.5 Gost 22520-85 (Kipia, Chpp-2), Usb/Rs485 Interface Converter With Galvanic Isolation For Configuring System Devices. Powered By Usb Port. Gost R 56947-2016 (Kipia, Chpp-2), Technical Pressure Gauge, Pressure Gauge Body Diameter 100 Mm, Pressure Measurement Range From 0...16 Kgf/Cm2, Accuracy Class 1.5, Connection Thread M20*1.5, Gost 2405-88 (Kipia, Chpp-2), Technical Pressure Gauge. Pressure Gauge Body Diameter 100 Mm, Pressure Measurement Range From 0...6 Kgf/Cm2, Accuracy Class 1.5, Connection Thread M20*1.5, Gost 2405-88 (Kipia, Chpp-2), Technical Pressure Gauge, Pressure Gauge (0...60 Kgf/Cm2), M20x1.5, 1.5 - Technical Pressure Gauge With A Body Diameter Of 160 Mm With A Radial Fitting Made Of Brass, With M20x1.5 Connection Thread And Accuracy Class 1.5. Gost 2405-88 (Kipia, Chp), Technical Pressure Gauge, Pressure Gauge Body Diameter 160 Mm, Pressure Measurement Range From 0...16 Kgf/Cm2, Accuracy Class - 1.5, Connection Thread M20*1.5, Gost 2405-88 (Kipia, K-3, Tsmk), Technical Pressure Gauge, Pressure Gauge Body Diameter 160 Mm, Pressure Measurement Range From 0...6 Kgf/Cm2, Accuracy Class 1.5, Connection Thread M20*1.5, Gost 2405-88 (Kipia, Chpp, Chpp-2, Tsmk), Technical Pressure Gauge, Pressure Gauge Body Diameter 100 Mm, Pressure Measurement Range From 0...25 Kgf/Cm2, Accuracy Class 1.5, Connection Thread M20*1.5, Gost 2405-88 (Kipia, Chpp-2, Ktr), Flame Detector, Supply Voltage – 220 V (+10, - 15)% With A Frequency Of 50 Hz. Power Consumption From The Network Is No More Than 15 Va. The Operating Frequency Range Of Flame Pulsations Is 3-9 Hz. The Range Of Spectral Characteristics Of Photo Sensors Is In The Wavelength Range From 0.4 To 1.1 Microns. The Minimum Threshold For The Response Of Photodetectors In Terms Of Illumination Is No More Than 2 Lux. The Multiplicity Of Change In The Response Setting Is At Least 5. The Load Of The Output Relay Is An Active-Inductive Dc Circuit With The Following Parameters: Current Strength No More Than 0.5 A; Voltage No More Than 220 V; T - No More Than 0.015 S. The Length Of The Communication Line Between Each Photosensor And The Alarm Device Is Up To 150 Meters. Complete With Installation And Spare Parts. Overall Dimensions: Signaling Device – 350 X 100 X 180 Mm; Photosensor – 125 X 80 X 100 Mm. Weight: Signaling Device – No More Than 3.35 Kg; Photosensor – No More Than 1.0 Kg; Set Of Mounting Parts – No More Than 6.0 Kg. Gost 52229-2004 (Kipia, Chp)

Key Value

Tender Value
2,75,97,557 - KZT

Attachment

FileName File Description
Global Tender Document 7e77336a-0763-432c-9b52-e25bd38f84c3.html
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail

WhatsApp