GTR 111487071

Tenders Are Invited For Renewal Of Hydraulic, Electrical And Control Installation Frisiabrêge In Franeker Specifications 25-34-Kb.

ICB — International Competitive Bid Closed Western Europe
Tender Information
GTR Reference
111487071
Tendering Authority
Subscribe to view
Tender No
9e81144a-995c-46c4-9e18-88a45b6a29e8
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Renewal Of Hydraulic, Electrical And Control Installation Frisiabrêge In Franeker Specifications 25-34-Kb.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Western Europe
Political Region
European Union
Last Date of Bid Submission
27-05-2026 Closed
Work Detail
The Work To Be Carried Out In Relation To The Frisiabrêge Mainly Consists Of, But Is Not Limited To, The Manufacture, Delivery, Installation And Complete Operational Delivery Of: 1. Dismantling And Removing The Existing E&Ia Installation; 2. Dismantle And Dispose Of Existing Hu Set; 3. Replace Hu Set And Overhaul Complete Hydraulic Installation; 4. Cleaning And Preserving Designated Bridge Parts And Structures; 5. Replace Complete E&Ia Installation Including All Cabling; 6. Revised Closure Plan On The South Side Of The Bridge According To The New (Plot) Drawing; 7. Move Position Three (3) Barrier Boxes On The Southern Main Road Towards The Fall; 8. Six (6) Pieces Of Completely New Barriers Incl. Columns According To Nen6787. 9. Make All Six (6) Asb Cabinets In Type Nma-Bas 1; 10. New Barrier Barriers According To Nen6787 And No Longer Use Wokkel Marking; 11. Six (6) Eba Speakers To Be Installed In The New Asb Cabinets; 12. New Marine Radio Station Including Directional Antennas On The New Tilting Mast On The Basement Deck; 13. Replacing And Installing Weather Facilities On The Tilting Mast On The Basement Deck; 14. Completely New Mep Audio Equipment For 8 Zones (2 Pieces Pau); 15. Three (3) Horn Loudspeakers For Speaking/Listening To Road Traffic; 16. Two (2) Horn Loudspeakers For Speaking/Listening To Shipping Traffic; 17. One (1) Piece (Small) Horn Speaker For Speaking/Listening Cbk Bridge Cellar; 18. Maintain Both Registration Posts And Provide Each With New Speakers; 19. Install Two (2) New Reporting Buttons And Signage On Each Registration Post; 20. Maintain Existing Front Signals At Approximately 150M But Connect Them With New Cables; 21. Newly Coat All Six (6) Stop Signal Masts In Accordance With Nen3322 Black/White Checkered; 22. Move The Position Of Three (3) Stop Signal Masts On The Southern Main Road Towards The Fall; 23. All Stop Signal Masts Equipped With New 3-Aspect Led2 Signals Red-Yellow-Red; 24. Two (2) Parallel Road Stop Signal Masts Fitted With New Underlights; 25. Apply Six (6) New Boom Control Units (Bsu) For Asb In Cbk; 26. Apply Six (6) New Eba Boards For Asb In Cbk; 27. Replace All Shipping Signals Including Odvs On Existing (Tilting) Structures; 28. Execute Shipping Signals Svs And Odvs In Led2 According To Plot Drawing; 29. Power Supply Distributor Incl. Kwh Maintain With Fuses Of 3 * 250A+ N+Pe; 30. Supply And Install A Completely New Control Box (Cbk) Approx. 3.2 * 2.0 * 0.6M; 31. New Network Cabinet Pf For Remote Control Pf As Part Of The Cbk; 32. Maintain Existing Ups Cabinet For 19 Patch Panels At Existing Location; 33. Move Of (Long-Distance) 2U Patch Panel To The Ups Cabinet To Be Maintained; 34. Two (2) Pieces Of New Encoder Using Standard Software; 35. Replace Existing Encoders Compared To Current Transmissions Of Main Pivot Points; 36. New Hu Set Using Two (2) Pieces Controlling Sto Soft Starters; 37. New Hu Control Using 2 Control Units Based On Digital Control And Feedback; 38. Integrating Redundancy (Half Speed) Based On A Single Hu Set 41. Reusing All Existing Camera Masts; 42. Installing 6V Mm Fiber Optic Routes To 5 Existing Camera Masts; 45. Installing A Second Connection Box In A Cabinet With A Viewing Door Near The Basement Entrance; Plc And Head Station In Network Section According To Blueprint Pf; 47. Remote Control Entirely According To Typicals / Standard Software Pf V. 4.0; 48. Control Installation Completely Replaced By Fail-Safe Plc / Hmi Facilities; 49. Existing Cabling Via Existing Water And Road Crossings Entirely Replace; 52. Reuse Existing Cable Paths As Much As Possible After Removing Old Cables; 53. Move Patch Panel, 2He For 1 * 96V Sm Fiber Optics To Ups Cabinet 54. All Additional Required Excavation And Cable Work; 58. Documentation And Registration.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
8811805e-d29d-4c9f-a410-c5772a7cafa5.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.