GTR 111246870

Request For Quotation Medical Consumables

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
111246870
Tendering Authority
Subscribe to view
Tender No
16694804
Financer Name
Self-Funded
Work Title
Request For Quotation Medical Consumables
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
03-04-2026 Closed
Work Detail
Volume (Packing): 9X15 Ml The Set Is Intended For Use On Any Open-Type Biochemical Analyzers Manufactured From High-Quality Imported Raw Materials Linearity Range: From 1 To 11.3 Mmol/L Low Coefficient Of Variation Of Determination Results - No More Than 5%. The Calibrator Is Part Of The Lipoprotein Lipase Kit Catalyzes The Hydrolysis Reaction Of Triglycerides With The Formation Of Fatty Acids And Equimolar Amounts Of Glycerol. Glycerol, In The Presence Of Atp, Hexokinase And Glycerophosphate Oxidase, Is Oxidized By Atmospheric Oxygen To Form An Equimolar Amount Of Hydrogen Peroxide. In The Presence Of Peroxidase, Hydrogen Peroxide Oxidizes 4-Aminoantipyrine And Chlorophenol To Form Red Quinoemine, The Color Intensity Measured At 505 Nm Is Proportional To The Concentration Of Triglycerides In The Sample. (For The Semiautomatic Biochemical Analyzer Bts-350), Volume (Packing): 4X100 Ml The Set Is Intended For Use On Any Open-Type Biochemical Analyzers Made From High-Quality Imported Raw Materials Linearity Range: From 20 To 120 G/L, Low Coefficient Of Variation Of Determination Results - No More Than 5%. The Calibrator Is Part Of The Kit. Proteins React In An Alkaline Medium With Copper Sulfate, Forming A Compound Colored Violet, The Intensity Of Which Is Proportional To The Protein Concentration. (For The Semiautomatic Biochemical Analyzer Bts-350), Determination Of The Concentration Of C-Reactive Protein In Serum By Manual Method 10 Ml, A Set Of Reagents For The Detection Of Syphilis (Microreaction To Syphilis) With Cardiolipin Antigen And Carbon Agglutination - Is A Test For The Formation Of Black Visible Clots On Samples As A Result Of A Reaction To The Rpr Antigen (In Case Of A Positive Test Result). Manual Method 3 Ml, Volume (Packing): 4X50 Ml 5X10 Ml The Set Is Intended For Use On Any Open-Type Biochemical Analyzers Produced From High-Quality Imported Raw Materials Linearity Range: From 15 To 3000 U/L Low Coefficient Of Variation Of Determination Results - No More Than 5%. The Calibrator Is Part Of The Α-Amylase Kit Hydrolyzes The Substrate 2-Chloro-4-Nitrophenyl-Α-D-Maltotrioside (Cnp-G3) To Carbohydrate Polymers And P-Nitrophenyl-Oligosaccharide From Short Chains, And Forms 2-Chloro-4-Nitrophenol (Cnp). To Determine The Activity Of Α-Amylase, Measure The Rate Of Cnp Formation On A Spectrophotometer At A Wavelength Of 405 Nm (For The Biosystems Bts-350 Semi-Automatic Analyzer), Volume (Packing): 2X50 Ml The Set Is Intended For Use On Any Open-Type Biochemical Analyzers Manufactured From High-Quality Imported Raw Materials Linearity Range: From 10 To 440 U/L Low Coefficient Of Variation Of Determination Results - No More Than 5%. The Calibrator Is Part Of The Kit Enzyme Alanine Aminotransferase (L-Alanine: 2-Oxoglutarate Aminotransferase; E.F. 2.6.1.1) - Alt Or Alt, Catalyzes The Reversible Transfer Of Amino Groups From L-Alanine To Α-Ketoglutaric Acid With The Formation Of Pyruvate. Lactate Is Formed From Pyruvate Under The Action Of The Enzyme Ldh (Lactate Dehydrogenase), And Nadh Is Converted Into The Oxidized Form Of Nad. The Rate Of Nadh Oxidation Is Directly Proportional To The Activity Of Alanine Aminotransferase And Is Measured Photometrically At A Wavelength Of 340 Nm (For The Semiautomatic Biochemical Analyzer Bts-350), Volume (Packing): 4X30ml 3X250ml 4X100ml The Set Is Intended For Use On Any Open-Type Biochemical Analyzers Produced From High-Quality Imported Raw Materials Linearity Range: 0.5 – 18.1 Μmol/L. Low Coefficient Of Variation Of Determination Results - No More Than 5%. The Calibrator Is Included In The Kit. Cholesterol Esters Are Converted By Cholesterol Esterase To Cholesterol, Which Is Oxidized By Cholesterol Oxidase To Form Hydrogen Peroxide. Phenol And 4-Aminoantipyrine, Under The Influence Of The Resulting Hydrogen Peroxide And Peroxidase, Form A Colored Complex, The Color Intensity Of Which At 500 - 546 Nm Is Proportional To The Cholesterol Content. (For The Semiautomatic Biochemical Analyzer Bts-350), Volume (Packing): 2X50 Ml The Set Is Intended For Use On Any Open-Type Biochemical Analyzers Manufactured From High-Quality Imported Raw Materials Linearity Range: From 10 To 440 U/L Low Coefficient Of Variation Of Determination Results - No More Than 5%. The Calibrator Is Part Of The Kit Enzyme Aspartate Aminotransferase (L-Aspartate: 2-Oxoglutarate Aminotransferase; E.F. 2.6.1.1) - Ast Or Ast, Catalyzes The Reversible Transfer Of Amino Groups From L-Apartate To Α-Ketoglutaric Acid With The Formation Of Oxaloacetate. Malate Is Formed From Oxaloacetate Under The Action Of The Enzyme Mdh (Malate Dehydrogenase), And Nadh Is Converted Into The Oxidized Form Of Nad. The Rate Of Nadh Oxidation Is Directly Proportional To The Activity Of Alanine Aminotransferase And Is Measured Photometrically At A Wavelength Of 340 Nm (For The Semiautomatic Biochemical Analyzer Bts-350), Volume (Packing): 200 Ml The Kit Is Intended For Use On Any Open-Type Biochemical Analyzers Manufactured From High-Quality Imported Raw Materials Linearity Range: 30 To 2212 Μmol/L Low Coefficient Of Variation Of Determination Results - No More Than 5%. The Calibrator Is Included In The Kit. In An Alkaline Environment, Creatinine Forms A Colored Complex With Picric Acid. The Reaction Rate Is Proportional To The Concentration Of Creatinine In The Sample. With This Measurement Method, The Influence Of Nonspecific Factors Is Reduced. Creatinine Is Formed From Creatine, An Acid That Is Involved In Energy Metabolism In Muscle Cells. Every Day, About 2% Of Nitrogenous Carboxylic Acid Is Converted To Creatinine. It Reaches The Kidneys Through The Blood, Where It Is Filtered And Urine Is Formed. Most Creatinine Is Excreted From The Body Through The Kidneys. Throughout The Day, The Creatinine Content In The Blood Circulates At Approximately The Same Level. This Happens Because The State Of Muscle Mass Remains Unchanged. (For The Biochemical Analyzer, Semi-Automatic Bts-350), Volume (Packing): 200 Ml Reagent 1 – 1X100ml, Reagent 2 – 1X100ml, Enzyme Reagent – ​​1X1ml, Standard For Reagents: 1X3ml. The Kit Is Intended For Use On Any Open-Type Biochemical Analyzers. Manufactured From High-Quality Imported Raw Materials. Linearity Range: From 2 To 50 Mmol/L. Low Coefficient Of Variation Of Determination Results - No More Than 5%. The Calibrator Is Included In The Kit. Urea Is Converted Into Ammonia And Carbon Dioxide Under The Influence Of Urease. Ammonia, Interacting With Α-Ketoglutaric Acid With The Participation Of Glutamate Dehydrogenase (Gldh), Oxidizes Reduced Nicotine Adenine Dinucleotide, The Optical Density Of Which At 340 Nm Decreases In Proportion To The Urea Content. (For The Semiautomatic Biochemical Analyzer Bts-350)
Key Value
Tender Value
834,911 - KZT
Tender Documents
Global Tender Document
129f0e54-8f57-4fe1-9c34-b34fb9770991.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders