GTR 111217459

Bids Are Invited For Acquisition Of Laboratory Equipment For Health Unit Dr. Francisco Medeiros Dantas, From The Municipality Of Nova Palmeira-Pb, Through Federal Amendment Appeal - Proposal No. 08579.944000/1220-01.

ICB — International Competitive Bid Closed South America
Tender Information
GTR Reference
111217459
Tendering Authority
Subscribe to view
Tender No
00019/2026
Financer Name
Self-Funded
Work Title
Bids Are Invited For Acquisition Of Laboratory Equipment For Health Unit Dr. Francisco Medeiros Dantas, From The Municipality Of Nova Palmeira-Pb, Through Federal Amendment Appeal - Proposal No. 08579.944000/1220-01.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
13-04-2026 Closed
Work Detail
Automatic Biochemical Analyzer: Type Of Equipment: Random Access With Open And Closed Reagent System. • Processing Speed: 200 Constant Tests/Hour (Mono Or Bireagent). • Test Principle: Colorimetric And Turbidimetric. • Types Of Method: Endpoint, Fixed Time, Kinetic. • Calibration Types: Linear And Non-Linear. • Sample Bottles: Sample Cell Or Primary Tube. • Sample Volume: 2-30Μl ± 0.1Μl. • Reage Volume: 20-300Μl ± 1Μl. • Reaction Volume: 150-350Μl. • Reaction Time: 10 Minutes. • Temperature Control: Peltier Type (37ºc ± 0.1ºc). • Reaction Cell Washing: Automatic 12 Steps (3*4). • Noise Level: ? 40Db. • Absorbance Accuracy: 0.5 ± 0.025, 1.0 ± 0.07. • Absorbance Stability: ? 0.01. • Absorbance Repeatability: ? 1.5%. • Clinical Accuracy: Tgp ? 3%, Urea? 2.5%, Total Protein ? 2%. Power Cable: With 3-Pin Plug, Two Phases And One Ground - Nbr141362, Digital Water Bath With Circulation 40L 220V Gallery Of 20 And 5 Positions, Power: 2500 Watts, Accuracy +/- 0.5°C2, Working Temperature: +5°C Up To 100°C2, Microprocessed Digital Controller With Pid System, Autotuning And Double 4-Digit Display2, Flow: 10L/Minute2, Temperature Sensor: Pt 100, Power Cable: With 3-Pin Plug, Sae 1020 Carbon Steel Sheet, Anticorrosive Treatment, Rubber Feet, Cuba: Aisi 304 Stainless Steel, Internal Stainless Steel Grid For Resistance Protection. Heating System: Panel With Function Indications, On/Off Key, Softtouch Keyboard, Pid System, Registered With Anvisa. Rbc/Inmetro Calibration Certificate For The Temperature Controller, Rbc/Inmetro Calibration Certificate For The Equipment;, Automatic Coagulometer For Plasma Coagulation Analysis In Clinical Laboratories, With Integrated Printer And Software In Portuguese. 1 Channel With Pipette For Self-Pippeting That Electronically Activates The Coagulation Reaction Detection Channel; Sample Volume: ?40Μl, Reagent Volume: ?40Μl, Storage Capacity: Can Store More Than 10000 Sample Results, 220 V, Internal Calibration Curve, Stores Up To 10000 Samples, Auto-Pipetting: Comes With A Micro Pipette That Electronically Activates The Coagulation Reaction Detection Channel; Timer - Printer: Internal (For Printing All Reports), Internal Thermal Printer Methodology, Display: Lcd, Preferably With Blue Background, Reagents: Any Type - Open System, With Anvisa Registration, Homogenizer Voltage: Automatic Bivolt, Power: 24W, Frequency: 50/60 Hz, Display: Lcd Display 18 X 64, Speed: Adjustable Between 10 To 50 Rpm, Cabinet: Fiberglass, Horizontal System: 360º Movement Around The Axis - Controller: Digital, Clips: Stamped In 304 Stainless Steel, Shelf: Standby Tube Holder (Up To 16 Tubes), Capacity: 28 Tubes 15 To 23 Mm, Variable Volume Autoclavable Micropipette, 100 To 1000Ul, Volume Display With Readout Of Up To 4 Digits For Precise Volume Control, Color Coded, Ergonomic And Lightweight One-Handed Operation., 03/31/2026 - 11:01:22, Total Digital Centrifuge, Speed: 4000Rpm (Adjustable), Increment: Every 10Rpm, Screen: Lcd That Shows Speed (Rpm) And Time (Minutes), With Membrane Type Keyboard, Force (Rcf): Minimum 1780Xg (Adjustable), Timer: 99 Minutes * Speed Accuracy: ± 10Rpm, Noise: ? 60Db, Rotor Capacity: 12X10ml / 12X15ml, Voltage / Frequency: 220V / 60Hz, Heart Monitor Display: 15`` Colorful (With Option
Key Value
Tender Value
153,834 - BRL
Tender Documents
Global Tender Document
47353ec0-70f9-4e74-ad0d-da2ad9808104.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders