GTR 110853368

Bids Are Invited For (Semad) Record Of Prices For Future And Possible Acquisition Of Fire Extinguishers And Future And Possible Provision Of Maintenance Services For 2Nd And 3Rd Level Fire Extinguishers (With Recharging), In Accordance With Brazilian Standard (Nbr) N. 12962 Of The Brazilian Association Of Technical Standards (Abnt).

ICB — International Competitive Bid Closed South America
Tender Information
GTR Reference
110853368
Tendering Authority
Subscribe to view
Tender No
6/2026
Financer Name
Self-Funded
Work Title
Bids Are Invited For (Semad) Record Of Prices For Future And Possible Acquisition Of Fire Extinguishers And Future And Possible Provision Of Maintenance Services For 2Nd And 3Rd Level Fire Extinguishers (With Recharging), In Accordance With Brazilian Standard (Nbr) N. 12962 Of The Brazilian Association Of Technical Standards (Abnt).
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
02-04-2026 Closed
Work Detail
Fire Extinguisher - 6 Kg Abc -- Abc Powder Extinguisher 6 Kg: Portable And Rechargeable Type; Extinguishing Agent: Dry Chemical Powder (Monoammonium Phosphate); Capacity: 6 Kg; Fire Classes A, B And C; Working Pressure: 10 Kgf/Cm²; According To Abnt Nbr 15808; Cargo Validity: 5 Years; Hydrostatic Test Validity: 5 Years., Carbon Dioxide (Co₂) 6 Kg Fire Extinguisher -- Carbon Dioxide (Co₂) 6 Kg Fire Extinguisher: Portable And Rechargeable Type; Extinguishing Agent: Carbon Dioxide; Capacity: 6 Kg; Fire Classes B And C; According To Abnt Nbr 15808; Cargo Validity: 5 Years; Hydrostatic Test Validity: 5 Years., Level 2 And Level 3 Preventive Maintenance On Abc Chemical Powder Type Fire Extinguishers -- Level 2 And Level 3 Preventative Maintenance On Abc Chemical Powder Type Fire Extinguishers – Nominal Capacity Of 6 Kg, In Full Compliance With Brazilian Standards Nbr 12962 And Nbr 15808, Both From The Brazilian Association Of Technical Standards – Abnt. The Services Will Comprehensively Include: Preventive Maintenance With Recharging (Levels 2 And 3):• Disassembly, Complete Physical Inspection And Structural Check Of The Cylinder And Components;• Total Discharge Of The Extinguishing Agent;• Internal Cleaning Of The Cylinder;• Recharging With Chemical Powder Type Extinguishing Agent Dry Class A, B And C, Duly Certified;• Repressurization, Replacement Of Seal, Conformity Seal And Maintenance Label;• Issuance Of Certificate/Technical Report Of Conformity. Verification Of The Hydrostatic Test:• Control Of The 5 (Five) Year Period For Carrying Out The Hydrostatic Test, In Accordance With Applicable Regulations;• Execution Of The Test Hydrostatic Testing Whenever The Equipment Reaches The Regulatory Deadline Or When There Is A Technical Indication.Corrective Maintenance:• Replacement Of Necessary Parts And Components, Including Hoses, Manometers, Valves, Triggers And Other Items That Show Wear Or Nonconformity;• Painting The Cylinder When Necessary• Perform The Hydrostatic Test In Cases Where Necessary., Level 2 And Level 3 Preventive Maintenance On Abc Chemical Powder Type Fire Extinguishers -- Level 2 And Level 3 Preventive Maintenance On Abc Chemical Powder Type Fire Extinguishers 4 Kg, Level 2 And Level 3 Preventative Maintenance On Dry Chemical Powder Type Fire Extinguishers (Class Bc) -- Level Preventive Maintenance 2 And Level 3 In Dry Chemical Powder Type Fire Extinguishers (Class Bc) 6Kg, Complete Physical Inspection And Structural Check Of The Cylinder And Components;• Total Discharge Of The Extinguishing Agent;• Internal Cleaning Of The Cylinder;• Refill With Dry Chemical Powder Type Extinguishing Agent Class Bc 6Kg, 03/23/2026 - 13:22:04, Level 2 And Level 3 Preventative Maintenance On Dry Chemical Powder Type Fire Extinguishers (Class Bc) -- Level 2 And Level 3 Preventive Maintenance On Dry Chemical Powder Type Fire Extinguishers (Class Bc) 4Kg, Complete Physical Inspection And Structural Check Of The Cylinder And Components;• Total Discharge Of Extinguishing Agent;• Internal Cleaning Of The Cylinder;• Refilling With Class Bc 4Kg Dry Chemical Powder Type Extinguishing Agent, Triggers And Other Items That Show Wear Or Non-Conformity;• Painting Of The Cylinder When Necessary• Carry Out The Hydrostatic Test, In Cases Where It Is Necessary, Level 2 And Level 3 Preventive Maintenance On Fire Extinguishers. Pressurized Water Type Fire (Class A) -- Level 2 And Level 3 Preventive Maintenance On Pressurized Water Type Fire Extinguishers (Class A) 10L., Physical Inspection
Key Value
Tender Value
107,869 - BRL
Tender Documents
Global Tender Document
9abb81ff-72b5-427f-a79d-6a3194ce1922.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders