Wash Solution 2000 Ml Alkaline Detergent. Control Material “Control Serum For Biochemical Studies Level 2”, Lyophilized Preparation From Light Yellow To Light Cream Color For Assessing The Accuracy And Reproducibility On The Dirui Cs-T240 Biochemical Analyzer Of The Following Parameters: Alb, Alp, Alt, Amy, Ast, Bun, Urea, Ca-Cpc, Ca-Ars, Che, Ck, Cl, Co2, Cre, Cre-Enzyme, D-Bil, D-Bil-V, Ggt, Gldh, Glu-Hk, Glu-Ox, Hbdh, K, Lap, Ldh, Mg-Xb, Na, P-Amy, Phos, Tb, Tb-V, Tba, Tc, Tg, Tp, Ua, Zn, Fe, Tibc. Packaging 5 Ml X 4. There Are Additional Services: Visit Of A Certified Specialist For Adaptation Of The Reagent (Dirui Cs-T240 Device). 51352-99, The Reagent Is Used For Quantitative In Vitro Measurement Of Immunoglobulin-M (Igm) In Human Serum On The Dirui Cs-T240 Biochemical Analyzer. Serum Or Plasma Is Mixed With An Anti-Human Igm Antibody In A Reagent, Which Leads To The Formation Of An Antigen-Antibody Complex, And A Certain Degree Of Turbidity Is Formed, The Intensity Of Which Is Directly Proportional To The Igm Content In The Serum. Serum Igm Content Can Be Calculated By Measuring The Turbidity Absorbance At 340 Nm And Comparing It To A Standard Curve. Reagents: R1 - Buffer. R2- Solution Containing Goat Anti-Human Igg Antibody. The Test Time Is 5 Minutes. Volume R1 - 50 Ml. Volume R1 -10 Ml. Sample Volume 3 Μl. The Number Of Tests Per Package Is No More Than 112. Calibrator Included. Reagent Control Is Carried Out On Control For Specific Proteins Level 1 And 2. Calibrator And Control From The Manufacturers Factory With Certified Values Of The Control Material And A Calibrator With A Target Value. The Linear Range Of This Reagent Is 0.05 -3 G/L. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. The Distance Between The Bottom Of The Bottle And The Barcode Should Be Within The Range Of 15Mm-25Mm. The Purchase Of Goods Includes A Related Service: The Visit Of A Certified Specialist To Adapt The Reagent. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Specific Protein Control Serum Level 1 - Liquid, Ready For Use. Designed To Evaluate The Accuracy And Reproducibility Of Results On The Cs-T240 Biochemical Analyzer For The Following Parameters: Iga/Igm/Igg/C3/C4/Pa/Trf/Β2-Mg/Aso/Rf/Crp/Alb/Rbp. Packaging 1*1 Ml. Composition: Mannitol 50 G/L; Trehalose 20 G/L; Peg 25 G/L; Purified Human Serum. Shelf Life: 24 Months At A Temperature Of 2°C~8°C, Stability Of An Opened Bottle Is 30 Days At A Temperature Of 2°C~8°C. Coefficient Of Variation Cv<5.0%. The Purchase Of Goods Includes A Related Service: The Departure Of A Certified Engineer From The Manufacturer’S Plant To Conduct Quality Control And Personnel Training. When Delivering Goods, The Supplier Must Provide A Registration Certificate, An Authorization Letter From The Manufacturer, A Certificate Of Quality-Conformity, A Certificate Of Origin Of The Goods, A Power Of Attorney For The Right To Sell The Goods On The Territory Of The Republic Of Kazakhstan, A Coupon For Medical Activities. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Gamma-Glutamyl Transferase (Y-Glutamyl Transferase)-Ggt. Gamma-Glutamyl Transferase Γ-Glutamyl Transferase. The Reagent Is Used For Quantitative In Vitro Measurement Of Γ-Gt Activity In Human Serum And Plasma On The Cs-T240 Biochemical Analyzer. This Reagent Contains Soluble Glucana Substrate Recommended By The Ifc. Glutamyl From The Γ-Gt Catalytic Substrate Is Transferred To Glycylglycine, Resulting In The Formation Of Glutamyl Glycylglycine And 5-Amino-2-Nitrophenyl Format. Components: Reagent 1- Tris Buffer 100 Mmol/L; Sodium Chloride 5 Mmol/L; Glycylglycine 125 Mmol/L. Reagent 2- Tris Buffer 100 Mmol/L; L-Γ-Glutamyl-3-Carboxy-4-Nitroaniline 14.5 Mmol/L. Contains Non-Reactive Material And Stabilizer. Test Duration Is 60~120 Seconds. The Linear Range Of This Reagent Is 0~450 U/L (7.5 Μkat/L). Packaging R1 4X50 Ml R2 1X 50 Ml. The Number Of Tests Per Package Is At Least 671. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. The Distance Between The Bottom Of The Bottle And The Barcode Must Correspond To The Range Of 15Mm-25Mm. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Aspartate Aminotransferase -Ast. Aspartate Aminotransferase. The Reagent Is Used For Quantitative Measurement And Diagnostic Determination In Vitro Of Aspartate Aminotransferase (Ast) Activity In Serum Or Blood Plasma On The Cs-240 Biochemical Analyzer. The Reaction Principle Of This Reagent Follows The Method Recommended By The International Federation Of Clinical Chemistry (Ifcc). Aspartate Aminotransferase (Ast) In The Sample Catalyzes Amino-L-Aspartate, Resulting In The Conversion Of Α-Ketoglutarate To Acetic Acid Ester And L-Glutamate. The Acetic Acid Ester Is Reduced By Malate Dehydrogenase In The Reagent To L-Malic Acid. At This Time, Nadh Is Oxidized To Nad, So That The Light Absorbance Value At 340 Nm Decreases. By Monitoring The Rate Of Decrease In Absorbance Value At 340 Nm, Aspartate Aminotransferase (Ast) Activity Is Measured. Endogenous Pyruvate Interference Can Be Removed Quickly And Completely During Lag. Components: Reagent 1 - Lactate Dehydrogenase >1365 U/L; L-Aspartate 300 Mmol/L; Tris Buffer >80 Mmol/L; Edta 5.0 Mmol/L Tris Buffer >80 Mmol/L. Reagent 2 - Malate Dehydrogenase >1635 U/L; Α-Ketoglutarate 36 Mmol/L; Nadh >0.75Mmol/L; Tris Buffer >80 Mmol/L; Edta 5.0 Mmol/L. Contains Non-Reactive Material And Stabilizer. Test Duration Is 120~180 Seconds. The Linear Range Of This Regent Is 3 ~ 1000 U/L. Packaging R1 4X50 Ml R2 1X50 Ml. The Number Of Tests In The Package Is 587 For The Biochemical Analyzer Dirui. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, The Reagent Is Used For Quantitative In Vitro Measurement Of Immunoglobulin G (Igg) In Human Serum On The Dirui Cs-T240 Biochemical Analyzer. Serum Or Plasma Is Mixed With Anti-Human Igg Antibody In A Reagent, Resulting In The Formation Of An Antigen-Antibody Complex, Which Produces A Certain Degree Of Turbidity, The Intensity Of Which Is Directly Proportional To The Content Of Igg In The Serum. Serum Igg Content Can Be Calculated By Measuring The Turbidity Absorbance At 700 Nm And Comparing It To A Standard Curve. Reagents: R1: Buffer. R2: Solution Containing Goat Anti-Human Igg Antibody. The Test Time Is 5 Minutes. Volume R1 -50 Ml. Volume R2-10 Ml. Sample Volume 2 Μl. The Number Of Tests Per Package Is No More Than 100. Calibrator Included. Reagent Control Is Carried Out On Control For Specific Proteins Level 1 And 2. Calibrator And Control From The Manufacturers Factory With Certified Values Of The Control Material And A Calibrator With A Target Value. The Linear Range Of This Reagent Is 0.08 -6.0 G/L. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. The Distance Between The Bottom Of The Bottle And The Barcode Should Be Within The Range Of 15Mm-25Mm. The Purchase Of Goods Includes A Related Service: The Visit Of A Certified Specialist To Adapt The Reagent. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Total Protein Tp. The Reagent Is Used For Quantitative In Vitro Measurement Of The Concentration Of Total Protein (Tp) In Human Serum Or Plasma On The Dirui Cs-T240 Biochemical Analyzer. This Reagent Uses The Biuret Reaction Method, I.E., The Reaction Between The Peptide Bond Of A Protein Molecule And A Copper Ion Forms A Blue-Purple Complex In An Alkaline Solution. Each Copper Ion Forms A Complex With 5-6 Peptide Bonds. Adding Iodide To The Reagent Can Prevent Automatic Reversal Of The Copper Compound. The Blue-Magenta Pigment Is In Direct Proportion To The Total Protein Concentration, Which Can Be Calculated By Measuring The Changes In Absorbance At 520~560Nm. When Using Dual Beam Analysis, The Wavelength Of The Blank Solution Should Be Set To 600~700Nm. Components: Copper Sulfate 12 Mmol/L; Potassium Sodium Tartrate 64 Mmol/L; Potassium Iodide 6 Mmol/L; Sodium Hydroxide 200 Mmol/L. Exchange Of Components From Different Reagent Lots Is Prohibited. Reaction Duration Is 300 Seconds. The Linear Range Of This Reagent Is 0-150 G/L; Volume R1-250 Μl Sample Volume-5 Μl. The Number Of Tests Per Package Is At Least 800. Calibrator Included. Reagent Calibration Is Also Carried Out Using A Multicalibrator. The Reagent Is Monitored Using Multicontrol Levels 1 And 2. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Lipid Control Serum Level 1 - Lyophilized Powder. Used To Evaluate The Accuracy And Reproducibility Of Results On The Cs-T240 Biochemical Analyzer For The Following Parameters: Apoa1/Apob/Tc/Hdl-C/Ldl-C/Lp(A)/Tg. Packaging: 1X1 Ml. Composition: Mannitol 50 G/L, Trehalose 20 G/L; Peg6000 25 G/L; Human Serum. Expiration Date: Indicated On The Box Label, Store The Control In A Dark Place At A Temperature Of 2°C~8°C. Dissolved Lipid Control Is Stable For 7 Days After Opening When Stored At 2°C~8°C, 4 Weeks When Stored At -20°C. Coefficient Of Variation Cv<5.0%. The Purchase Of Goods Includes A Related Service: The Departure Of A Certified Engineer From The Manufacturer’S Plant To Conduct Quality Control And Personnel Training. When Delivering Goods, The Supplier Must Provide A Registration Certificate, An Authorization Letter From The Manufacturer, A Certificate Of Quality-Conformity, A Certificate Of Origin Of The Goods, A Power Of Attorney For The Right To Sell The Goods On The Territory Of The Republic Of Kazakhstan, A Coupon For Medical Activities. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Antibacterial Phosphorus-Free Detergent 500Ml. Cs-Anti-Bacterial Phosphor-Free Detergent. For Cleaning The Reagent Sampling Probe, Reaction Cuvette And Reaction Soaking Cup Of The Dirui Cs-T240 Autochemistry Analyzer. Sodium Hydroxide Surfactant Can Remove Organic Matter Such As Protein, And Bacteriostats Can Inhibit The Growth Of Bacteria. Ingredient - Sodium Hydroxide Surfactant, Bacteriostats. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Creatinine. The Kit Is Intended For The Quantitative Determination Of Creatinine Content (Cre - Vit) In Serum, Blood Plasma Or Urine By A Two-Point (Pseudokinetic) Method On The Dirui Cs-T240 Biochemical Analyzer. The Rate Of Formation Of A Colored Complex With Picric Acid In An Alkaline Medium (Jaffe Reaction) Is Proportional To The Concentration Of Creatinine In The Sample And Is Measured Photometrically At A Wavelength Of 505 Nm. Reagent No. 1. Sodium Hydroxide. 260 Mmol/L; Detergent. 20 G/L. Reagent No. 2.-Picric Acid .20 Mmol/L. Calibrator - 177 Μmol/L (2 Mg/Dl). Linearity Range 25–885 Μmol/L. The Test Time Is 13 Minutes. Mix Reagents R1 And R2b In Equal Quantities. Volume R1-180 Μl. Sample Volume -35 Μl. The Number Of Tests Per Package Is At Least 150. .Calibrator Included. Reagent Control Is Carried Out On Multicontrol Levels 1 And 2. It Is Registered Manually In The Analyzer. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Specific Protein Control Serum Level 2 - Liquid, Ready For Use. Designed To Evaluate The Accuracy And Reproducibility Of Results On The Cs-T240 Biochemical Analyzer For The Following Parameters: Iga/Igm/Igg/C3/C4/Pa/Trf/Β2-Mg/Aso/Rf/Crp/Alb/Rbp. Packaging 1*1 Ml. Composition: Mannitol 50 G/L; Trehalose 20 G/L; Peg 25 G/L; Purified Human Serum. Shelf Life: 24 Months At A Temperature Of 2°C~8°C, Stability Of An Opened Bottle Is 30 Days At A Temperature Of 2°C~8°C. Coefficient Of Variation Cv<5.0%. The Purchase Of Goods Includes A Related Service: The Departure Of A Certified Engineer From The Manufacturer’S Plant To Conduct Quality Control And Personnel Training. When Delivering Goods, The Supplier Must Provide A Registration Certificate, An Authorization Letter From The Manufacturer, A Certificate Of Quality-Conformity, A Certificate Of Origin Of The Goods, A Power Of Attorney For The Right To Sell The Goods On The Territory Of The Republic Of Kazakhstan, A Coupon For Medical Activities.. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Glucose-Oxidase - Glu-Ox. Glucose-Oxidase Glucose-Oxidase. The Reagent Is Used For Quantitative Determination In Vitro Of The Concentration Of Glucose Contained In Serum, Blood Plasma Or Urine On The Cs-240 Biochemical Analyzer. Glucose In The Sample, When Activated By Hexokinase (Hk) And Glucose-6-Phosphate Dehydrogenase (G6pdh), Reacts With Atp, Resulting In The Formation Of Glucose-6-Phosphate And Adenosine Diphosphate. Glucose - 6 - Phosphoric Acid Is Oxidized To 6 -Phosphate Glucose In Fats, And At This Time The Nad In The Reagent Is Reduced To Nadh, Causing An Increase In The Light Absorption Value At 340 Nm. The Nadh Value Is Proportional To The Amount Of Glucose. The Calculation Of Glucose Concentration Is Carried Out By Measuring The Change In Absorbance Value At 340 Nm. Components: Reagent 1 -Trifosadenine 1.30 Mmol/L; Hexokinase >1500 U/L; G-6-Pdh >2500 U/L; Buffer 50 Mmol/L. Reagent 2-Nadh 0.65 Mmol/L; Buffer 50 Mmol/L. Contains Non-Reactive Material And Stabilizer. Test Duration Is 300~600 Seconds. The Linear Range Is 0-40 Μmol Per L (720 Mg/Dl). Packaging R1 4X50ml R2 1X 50Ml. The Number Of Tests In The Package Is 587. For The Biochemical Analyzer Dirui. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, The Reagent Is Used For In Vitro Quantitative Determination Of Calcium Concentration In Serum, Plasma Or Urine On The Dirui Cs-T240 Biochemical Analyzer. Arsenazo Iii Reagent Binds To The Calcium Ion Of The Sample And Forms The Purple Arsenazo Ii-Calcium Combination. The Content In The Combination Is In Direct Proportion To The Calcium Concentration In The Sample. The Calcium Concentration Can Be Calculated By Measuring The Change In Absorbance Value At 650~660 Nm. Components (Working Reagent): Buffer 150 Mmol/L; Arsenazo Iii 150 Μmol/L; Surface Active Reagent 0.5%. The Test Time Is 60-120 Seconds. Volume R1-300 Microns. Sample Volume Is 3 Μl. The Number Of Tests Per Package Is No More Than 734. Calibrator Included. Reagent Calibration Is Also Carried Out Using A Multicalibrator. The Reagent Is Monitored Using Multicontrol Levels 1 And 2. Calibrator And Control From The Manufacturers Factory With Certified Values Of The Control Material And A Calibrator With A Target Value. The Linear Range For This Reagent Is 0-5.0 Mmol/L. Reagents Are Supplied In Disposable Original Packaging (Bottle). For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, The Reagent Is Used For Quantitative In Vitro Measurement Of Albumin Concentration (Alb) In Human Serum Or Plasma On The Dirui Cs-T240 Biochemical Analyzer. The Method Used To Analyze Serum Albumin Is The Dye-Binding Lysine (Dbl) Method. Dbl Technology Is Based On The Transfer Of The Largest Absorption Peak When The Dye Binds To Albumin. Absorption Peak Transfer Allows Measurement Of The Resulting Color In Circumstances Where Excessive Coloration Exists. Accuracy Is Ensured By The Presence Of A Cooperative Ability Between The Dye And Albumin, Which Completely Integrates The Albumin Into The Reaction. The Use Of Bromocresol Green And Albumin At Ph4.0~4.2 Causes The Formation Of A Greenish-Blue Combination, Which Is Directly Related To The Concentration Of Albumin In The Sample. Albumin Concentration Can Be Calculated By Measuring The Absorbance Value At 580-630 Nm. When Using Double Beam Light, The Idler Wavelength Can Be Set To 600~700Nm. Компоненты: Бромгексоловый Зеленый 0.35 Ммоль/Л; Succinic Acid Buffer 50 Mmol/L; Sodium Azide 7.7 Mmol/L; Brij-35 1%. Время Проведения Теста 300 Сек. Volume R1-250 Ml. Sample Volume Is 2 Μl. Количество Тестов В Упаковке Не Более 730. Калибратор В Наборе. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. The Distance Between The Bottom Of The Bottle And The Barcode Should Be Within The Range Of 15Mm-25Mm. The Purchase Of Goods Includes A Related Service: The Visit Of A Certified Specialist To Adapt The Reagent. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Alanine Aminotransferase -Alt. The Reagent Is Used For Quantitative Measurement And Diagnostic Determination In Vitro Of Alanine Aminotransferase (Alt) Activity In Serum Or Blood Plasma On The Dirui Cs-T240 Biochemical Analyzer. The Reaction Principle Of This Reagent Follows The Method Recommended By The International Federation Of Clinical Chemistry (Ifcc). In The Presence Of Alt, L-Alanine Reacts With Α-Ketoglutarate To Form Pyruvate And L-Glutamate. Pyruvate Is Reduced To L-Lactate By Ldh Present In The Reagent And In The Meantime Nadh Is Oxidized To Nad, Thereby Reducing The Absorbance Value To 340 Nm. Alt Activity Can Be Tested By Measuring The Rate Of Absorption Decline At 340Nm. The Endogenetic Pyruvate Of The Sample Is Reduced By Ldh During The Reaction Lag Period So That It Does Not Interfere With The Test. Components: Reagent 1 - Alanine 600 Mmol/L; Ldh >1820U/L; Tris Buffer 80 Mmol/L. Reagent 2 - Tris Buffer 80 Mmol/L; Nadh >0.75 Mmol/L; Α-Ketoglutarate 36 Mmol/L. Contains Non-Reactive Material And Stabilizer. Test Duration Is 60-120 Seconds. Volume R1-240 Μl. Volume R2-60 Μl. Sample Volume-15 Μl. The Number Of Tests In The Package Is At Least 587. Reagent Calibration Is Carried Out On A Multicalibrator. Reagent Control Is Carried Out On Multicontrol Levels 1 And 2. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. The Distance Between The Bottom Of The Bottle And The Barcode Should Be Within The Range Of 15Mm-25Mm. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Total Bilirubin - Tb. The Reagent Is Used For Quantitative In Vitro Measurement Of The Concentration Of Total Bilirubin (Tb) In Human Serum Or Plasma On The Dirui Cs-T240 Biochemical Analyzer. The Reagent Uses A Surfactant As A Solvent. Bound Bilirubin And Unbound Bilirubin That Have Been Dissolved React With Diazo-Sulfanilic Acid To Form Azo-Bilirubin. The Increase In Light Absorption At A Wavelength Of 570 Nm Is Proportional To The Concentration Of Total Bilirubin. The Concentration Of Total Bilirubin In A Sample Can Be Calculated By Checking The Change In Absorbance At 570 Nm. When Analyzing A Double Beam, The Wavelength Of The Blank Sample Should Be Set To 750 Nm. Components: Reagent 1 - Hydrochloric Acid 100 Mmol/L; Sulfanilic Acid 5 Mmol/L. Reagent 2- Sodium Nitrite 72 Mmol/L. Exchange Of Components From Different Batches Of Reagents Is Prohibited. Reaction Duration Is 300-600 Seconds. The Linear Range Of This Reagent Is 0~300 Μmol/L. Volume R1-250 Μl. Sample Volume-25 Μl. The Number Of Tests In The Package Is At Least 1068. Calibrator In The Kit. Reagent Calibration Is Also Carried Out Using A Multicalibrator. The Reagent Is Monitored Using Multicontrol Levels 1 And 2. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. The Distance Between The Bottom Of The Bottle And The Barcode Should Be Within The Range Of 15Mm-25Mm. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Serum For Clinical-Chemical Quality Control Level 1 - Lyophilized Powder From Light Yellow To Light Cream Color. Designed To Evaluate The Accuracy And Reproducibility Of Results On The Cs-T240 Biochemical Analyzer For The Following Parameters: Alb, Alp, Alt, Amy, Ast, Urea, Ca-Cpc, Ca-Ars, Che, Ck, Cl, Co2, Cre, Cre-Enzyme, D-Bil, D-Bil-V, Ggt, Gldh, Glu-Hk, Glu-Ox, Hbdh, Lap, Ldh, Mg-Xb, P-Amy, Phos, Tb, Tb-V, Tba, Tc, Tg, Tp, Ua, Zn, Fe, Tibc, K, Na, Acp, Lipase, Cu, Lactate. Packaging 5X4 Ml. Shelf Life Is 3 Years When Stored In An Airtight, Dark Place At 2°C~8°C. Once Opened And Dissolved, The Shelf Life Is 1 Day When Stored In Dark Places At 15°C~25°C; 7 Days If Stored In A Dark Place At 2°C~8°C; 30 Days When Stored In Dark Places At -20°C. The Purchase Of Goods Includes A Related Service: The Departure Of A Certified Engineer From The Manufacturer’S Plant To Conduct Quality Control And Personnel Training. When Delivering Goods, The Supplier Must Provide A Registration Certificate, An Authorization Letter From The Manufacturer, A Certificate Of Quality-Conformity, A Certificate Of Origin Of The Goods, A Power Of Attorney For The Right To Sell The Goods On The Territory Of The Republic Of Kazakhstan, A Coupon For Medical Activities.. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Serum For Clinical-Chemical Quality Control Level 2 - Lyophilized Powder From Light Yellow To Light Cream Color. Designed To Evaluate The Accuracy And Reproducibility Of Results On The Cs-T240 Biochemical Analyzer For The Following Parameters: Alb, Alp, Alt, Amy, Ast, Urea, Ca-Cpc, Ca-Ars, Che, Ck, Cl, Co2, Cre, Cre-Enzyme, D-Bil, D-Bil-V, Ggt, Gldh, Glu-Hk, Glu-Ox, Hbdh, Lap, Ldh, Mg-Xb, P-Amy, Phos, Tb, Tb-V, Tba, Tc, Tg, Tp, Ua, Zn, Fe, Tibc, K, Na, Acp, Lipase, Cu, Lactate. Packaging 5X4 Ml. Shelf Life Is 3 Years When Stored In An Airtight, Dark Place At 2°C~8°C. Once Opened And Dissolved, The Shelf Life Is 1 Day When Stored In Dark Places At 15°C~25°C; 7 Days If Stored In A Dark Place At 2°C~8°C; 30 Days When Stored In Dark Places At -20°C. The Purchase Of Goods Includes A Related Service: The Departure Of A Certified Engineer From The Manufacturer’S Plant To Conduct Quality Control And Personnel Training. When Delivering Goods, The Supplier Must Provide A Registration Certificate, An Authorization Letter From The Manufacturer, A Certificate Of Quality-Conformity, A Certificate Of Origin Of The Goods, A Power Of Attorney For The Right To Sell The Goods On The Territory Of The Republic Of Kazakhstan, A Coupon For Medical Activities. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Serum For Clinical-Chemical Calibration Is Made On The Basis Of Human Biomaterial; Lyophilized Powder Is Intended For Calibration Of A Number Of Biochemical Parameters On The Cs-T240 Biochemical Analyzer. Parameters: Alb, Alp, Alt, Amy, Ast, Urea, Ca-Cpc, Ca-Ars, Che, Ck, Cl, Co2, Cre, Cre-Enzyme, D-Bil, D-Bil-V, Ggt, Gldh, Glu-Hk, Glu-Ox, Hbdh, Lap, Ldh, Mg-Xb, P-Amy, Phos, Tb, Tb-V, Tba, Tc, Tg, Tp, Ua, Zn, Fe, Tibc, Lactate, Acp, K, Na, Cu. Packaging 5X4 Ml. Shelf Life Is 3 Years When Stored In An Airtight, Dark Place At 2°C~8°C. Once Opened And Dissolved, The Shelf Life Is 8 Hours When Stored In Dark Places At 15°C~25°C; 7 Days If Stored In A Dark Place At 2°C~8°C; 30 Days When Stored In Dark Places At -20°C. The Purchase Of Goods Includes A Related Service: The Departure Of A Certified Engineer From The Manufacturer’S Plant To Calibrate The Analyzer And Train Personnel. When Delivering Goods, The Supplier Must Provide A Registration Certificate, An Authorization Letter From The Manufacturer, A Certificate Of Quality-Conformity, A Certificate Of Origin Of The Goods, A Power Of Attorney For The Right To Sell The Goods On The Territory Of The Republic Of Kazakhstan, A Coupon For Medical Activities. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, The Reagent Is Used For Quantitative In Vitro Measurement Of Immunoglobulin-A (Iga) In Human Blood Serum On The Dirui Cs-T240 Biochemical Analyzer. Serum Or Plasma Is Mixed With Anti-Human Iga Antibody In The Reagent, Resulting In The Formation Of An Antigen-Antibody Complex, Which Produces A Certain Degree Of Turbidity, The Intensity Of Which Is Directly Proportional To The Iga Content In The Serum Or Plasma. The Iga Content Of Plasma Or Serum Can Be Calculated By Measuring The Turbidity Absorbance At 340Nm And Comparing It To A Standard Curve. Reagents: R1 - Buffer. R2 -Solution Containing Goat Anti-Human Iga Antibody. The Test Time Is 5 Minutes. Volume R1 - 50 Ml. Volume R2- 10 Ml. Sample Volume -3 Microns. The Number Of Tests Per Package Is No More Than 112. Calibrator Included. Reagent Control Is Carried Out On Control For Specific Proteins Level 1 And 2. Calibrator And Control From The Manufacturers Factory With Certified Values Of The Control Material And A Calibrator With A Target Value. The Linear Range Of This Reagent Is 0.08 -6.0 G/L. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. The Distance Between The Bottom Of The Bottle And The Barcode Should Be Within The Range Of 15Mm-25Mm. The Purchase Of Goods Includes A Related Service: The Visit Of A Certified Specialist To Adapt The Reagent. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Total Cholesterol. Total Cholesterol Total Cholesterol. The Reagent Is Used For Quantitative In Vitro Measurement Of The Concentration Of Total Cholesterol In Human Serum Or Plasma On The Cs-T240 Biochemical Analyzer. The Cholesterol Ester In The Sample Is Selectively Catalyzed And Hydrolyzed Into Cholesterol And Free Fatty Acid By Lipopretein Esterase In The Reagent. The Resulting Total Cholesterol Is Oxidized By Cholesterol Oxidase To Form Cholest-4-Ene-3-Ene-3-Ketone And Hydrogen Peroxide. Under The Influence Of Peroxidase, Hydrogen Peroxide Reacts With Hydroxybenzoic Acid And 4-Amino-Antipyrine To Form H2o And Quinone Imine Pigment. In This Case, The Volume Of Quinone Imine Pigment Formed Is Proportional To The Content Of Total Cholesterol In The Sample. Therefore, Measuring The Volume Of Pigment Formed At A Certain Wavelength Makes It Possible To Calculate The Concentration Of Total Cholesterol. Components: Reagent 1- Lipoprotein Lipase > 300 U/L; Peroxidase > 750 U/L; P-Hydroxybenzoic Acid 45 Mmol/L; Triton X-100 0.3%; Buffer 50 Mmol/L. Reagent 2 - 4Aminoantipirn 0.3 Mmol/L; Cholesterol Oxidase > 300 U/L; Buffer 50 Mmol/L. Contains Non-Reactive Filler And Stabilizer. Reaction Time Is 5~10 Minutes. The Linear Range Of This Reagent Is 0-20 Mmol/L (774 Mg/Dl). Packing R1 4X50 Ml R2 1X50 Ml. The Number Of Tests Per Package Is At Least 587. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Lipid Control Serum Level 2 - Lyophilized Powder. Used To Evaluate The Accuracy And Reproducibility Of Results On The Cs-T240 Biochemical Analyzer For The Following Parameters: Apoa1/Apob/Tc/Hdl-C/Ldl-C/Lp(A)/Tg. Packaging: 1X1 Ml. Composition: Mannitol 50 G/L, Trehalose 20 G/L; Peg6000 25 G/L; Human Serum. Expiration Date: Indicated On The Box Label, Store The Control In A Dark Place At A Temperature Of 2°C~8°C. Dissolved Lipid Control Is Stable For 7 Days After Opening When Stored At 2°C~8°C, 4 Weeks When Stored At -20°C. Coefficient Of Variation Cv<5.0%. The Purchase Of Goods Includes A Related Service: The Departure Of A Certified Engineer From The Manufacturer’S Plant To Conduct Quality Control And Personnel Training. When Delivering Goods, The Supplier Must Provide A Registration Certificate, An Authorization Letter From The Manufacturer, A Certificate Of Quality-Conformity, A Certificate Of Origin Of The Goods, A Power Of Attorney For The Right To Sell The Goods On The Territory Of The Republic Of Kazakhstan, A Coupon For Medical Activities. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Alkaline Phosphatase - Alp. Alkaline Phosphatase Alkanine Phosphatase. The Reagent Is Used For Quantitative In Vitro Measurement Of Alkaline Phosphatase Activity In Human Serum Or Plasma On A Cs-240 Biochemical Analyzer. Alp In The Sample Catalyzes The Hydrolysis Of Rnpp To Form P-Nitrophenolate And Phosphate Acid, Which Causes An Increase In The Light Absorption Value At 405 Nm. The Alkali Phosphate Activity Of A Sample Is Calculated By Measuring The Rate Of Increase In Absorbance At 405Nm. Components: Reagent 1 - Magnesium Acetate 3.0 Mmol/L; Zinc Sulfate 1.5 Mmol/L; Hedta 3.0 Mmol/L; Buffer Amp 420 Mmol/L. Reagent 2 - P-Nitrobenzene Phosphate Acid 81.5 Mmol/L; Buffer Amp 420 Mmol/L. Contains Non-Reactive Filler And Stabilizer. The Linear Range Of This Reagent Is 0~850 U/L. Test Duration Is 60~120 Seconds. Packaging R1 4X50 Ml R2 1X50 Ml. The Number Of Tests In The Package Is 671. For The Determination Of Iron For The Dirui Device 4*50 Ml. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Urea (Urea) - Urea. The Reagent Is Used For Quantitative In Vitro Measurement Of Urea Concentration (Urea) In Blood Serum, Plasma Or Urine On The Dirui Cs-T240 Biochemical Analyzer. The Urea In The Sample, Catalyzed By The Urease In The Reagent, Reacts With Water To Produce Ammonia And Carbon Dioxide. Ammonia And Α-Ketoglutaric Acid In The Reactant Catalyzed By Glutamate Dehydrogenase (Gldh) Form Glutamic Acid, With Nadh Being Oxidized To Nad. Thus, The Absorption Of Light At 340 Nm Is Reduced. Monitoring The Level Of Light Absorption Reduction At 340 Nm Allows The Concentration Of Urea In The Sample To Be Calculated. Components: Reagent 1-Α-Ketoglutaric Acid 7.5 Mmol/L; Glutamate Dehydrogenase >800 U/L; Nadh 0.35 Mmol/L; Adenosine Diphosphate 1.5 Mmol/L; Tris Buffer 115 Mmol/L. Reagent 2 - Tris Buffer 115 Mmol/L; Urease > 40,000 U/L; Α-Ketoglutaric Acid 7.5 Mmol/L. Contains Non-Reactive Material And Stabilizer. Test Duration Is 60 Seconds. The Linear Range Of This Reagent Is 0-35 Mmol/L (Urea Nitrogen 98 Mg/Dl). Volume R1-240 Μl. Volume R2-60 Μl. Sample Volume-3 Μl. The Number Of Tests Per Package Is At Least 587. Calibrator Included. Reagent Calibration Is Also Carried Out Using A Multicalibrator. Reagent Control Is Carried Out On Multicontrol Levels 1 And 2. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. The Distance Between The Bottom Of The Bottle And The Barcode Should Be Within The Range Of 15Mm-25Mm. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99, Iron (Ferum) - Fe. Reagent Kit For Determination Of Iron (Fe). The Reagent Is Used For Laboratory Quantitative Detection Of Iron Content In Blood Serum On The Cs-T240 Biochemical Analyzer. Under Acidic Conditions, Whey Iron Fe Decomposes Into Its Constituent Parts; Fe Ion Reacts With A Chemical Reagent And A Chromogenic Reagent, Forming A Blue Mixture; At 600 Nm, The Change In Absorbance Is Measured; It Is Directly Proportional To The Concentration Of Iron Fe. Components: Reagent1 - Ethyl Acid Mixture 200 Mmol/L; Sulfourea 42 Mmol/L. Reagent 2 - Hydroxylamine Hydrochloride 200 Mmol/L; Ferene 2 Mmol/L. Reaction Time 300 Sec. Packaging R1 4×50 Ml. R2 2×20 Ml. The Number Of Tests Per Package Is At Least 633. Reagents Are Supplied In Disposable Original Packaging (Bottle). The Bottle Has An Individual Barcode, Which Contains Information About The Name Of The Reagent, The Type Of Reagent, The Volume Of The Reagent, The Date Of Production Of The Reagent, And The Expiration Date Of The Reagent. The Vial Barcode Must Be Compatible With The Analyzer Os And The Analyzer Security System. The Barcode Must Not Be Contaminated Or Damaged. The Distance Between The Bottom Of The Bottle And The Barcode Should Be Within The Range Of 15Mm-25Mm. For The Determination Of Iron For The Dirui Apparatus 4*50 Ml. For Replenishment, Modernization And Retrofitting Of The Main (Installed) Equipment. Gost R 51352-99