GTR 110063245
Bids Are Invited For The Purpose Of This Tender Is To Hire A Specialized Company For The Acquisition Of A Fixed Digital X-Ray Device, Including Installation, With Issuance Of The Appropriate Calibration Reports, As Well As The Supply Of The Necessary Accessories For The Regular Operation Of The Equipment, Intended To Meet The Demands Of The 24-Hour Emergency Service Of The Municipal Health Department Of Barra Velha/Sc.
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
110063245
Tendering Authority
Subscribe to view
Tender No
7/2025
Financer Name
Self-Funded
Work Title
Bids Are Invited For The Purpose Of This Tender Is To Hire A Specialized Company For The Acquisition Of A Fixed Digital X-Ray Device, Including Installation, With Issuance Of The Appropriate Calibration Reports, As Well As The Supply Of The Necessary Accessories For The Regular Operation Of The Equipment, Intended To Meet The Demands Of The 24-Hour Emergency Service Of The Municipal Health Department Of Barra Velha/Sc.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
25-03-2026
Closed
Work Detail
Fixed Microprocessed Radiodiagnostic Equipment From 10 To 800 Ma Or Greater With Error Indication And Level Of Kv, Ma And Mas, Anatomical Program Of Organs With A Minimum Of 200 Pre-Programmed Techniques. The Equipment Must Have Automatic Exposure Control (Aec) And Software For Indicating Dap, In Accordance With The Iec Standard. High Voltage Control And Generator: High Frequency Microprocessed X-Ray Generator; Power Of 64 Kw Or Greater; Selection From 40 To 150 Kv; Mas Range 0.1 To 800 Or Greater; Exposure Time Of 5 Ms Or Less Up To 5 Seconds, According To Rdc 611; Generator Must Be Installed Under The Table; It Has A Multicolored Lcd Display For Selection And Indication Of Radiological Parameters. X-Ray Tube Thermal Protection. Cables: High Voltage Cable Pair. Specific Power Chart Must Be Provided For The Equipment Bid. The Operating Characteristics Of The Rx Generator Must Be Available On The Operating Command, Allowing Selection Of Exposure Parameters In The Manner Mentioned Above. Bucky Mural: Vertical Offset Of 100 Cm Or Greater; With Fixed Anti-Diffusion Grid Of At Least 40 Lp/Cm; Bucky With Fixed Grid; Electromagnetic Or Mechanical Brakes; With Location/Centering Cross Printed On The Top Of The Bucky; Variable Focus From 100 To 180 Cm. Table With Floating Top: Transverse And Longitudinal Movement; Bucky With Fixed Grid; Load Capacity Of At Least 210 Kg; With Fixed Anti-Diffusion Grid Of At Least 40 Lp/Cm; Electromagnetic Brakes For Top Movements; Top Dimensions (L X W) Of At Least 200 Cm X 80 Cm; Variable Focus From 100 To 180 Cm. Tube Holder Stand: Floor-Floor Type; Vertical Movement Of 140 Cm Or Greater; Longitudinal Movement Of At Least 260Cm; Electromagnetic Brakes; Tube Holding Arm Rotation ± 90°. X-Ray Tube: Fine Focus Of Maximum 0.6 Mm; Coarse Focus Of Maximum 1.2Mm; Anode Rotation Of At Least 9000 Rpm; Minimum Cooling Capacity Of 300 Khu. Detector: 01 (One) Wireless Detector Unit, With Cesium Iodide Scintillator...
Key Value
Tender Value
296,500 - BRL
Tender Documents
Global Tender Document
bd915aa5-02af-4f1e-acda-075ba2d37b42.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.