Computer (Desktop-Basic) - Minimum Specification: Complete Computer I3, 19 Inch Monitor, Emouse Keyboard, Core I3 Model, Installed Size: 8 Gb, Type: Ddr4, Maximum Expansion: Up To 32Gb (2 Slots 260 Pins), Sodimm 2133Mhz Ddr4, Ssd: 240 Gb, Network: Gigabit Ethernet (Lan), Source: 65 Watts, Automatic, Front Inputs: 2X Usb 1X P2, Stereo Microphone 3.5Mm, 1X P2 Stereo Headphone, 3.5Mm, Rear Inputs 4X Usb 3.0; 1X Hdmi 1X Vga;1X P2 (Headphone); 1X Rj-45(Ethernet); 1X Power Supply Connector, Monitorscreen Size: 19.5, Colors: 16.7M, Refresh Rate: 75Hz, Connections: Hdmi And Vga, Vesa Hole: Yes/ Resolution: 1440X900 Native, Additional Resolutions: 1600X900 Hd+ And 1920X1080 Full Hd/ Contrast Dynamic: 5,000,000:1, Brightness Rate: 220 Cd/M², Anti-Glare Screen: Yes, Configuration Menu: Yes, Tilt Adjustment: Yes, Bivolt: Yes, Automatic, Package Contents: Monitor, Power Supply And Hdmi Cable Must Come With Standard Abnt2 Keyboard And Ambidextrous Mouse, Laser Printer (Common) - Minimum Specification: That Are On Line Production By The Manufacturer; Standard Monochrome Color Laser Printer; Minimum Resolution Of 1200 X 1200Dpi; Speed Of 35 Pages Per Minute Ppm; Support A5, A4 Letter And Legal Paper Size; 200 Pages Input Capacity; Monthly Cycle Of 50,000 Pages; Usb Interface; Allow Sharing Via 10/100/100 Ethernet Network And Wifi802.11 B/G/N; Support Automatic Forward & Reverse; The Product Must Be New, Unused, Renovated Or Reconditioned Minimum Warranty Of 12 Months + Extended Warranty Of 01 Year By The Contractor, Air Conditioning - Minimum Specification: Split Capacity/Cycle: 9,000 To 12,000 Btus/ Cold., X-Ray Machine - Fixed Digital - Minimum Specification: Fixed Digital X-Ray Equipment, For General Radiology Imaging Including Complete Spine And Scanometry, With Unique Registration At Anvisa. Microprocessor With Image Capture Through Digital Detector, Containing Microprocessor Generator With At Least 65 Kw Of Nominal Power; Three-Phase Power Supply 380V At 50/60 Hz. Voltage Varied From At Least 40 To 125 Kv With Steps Of 01 Kv; It Must Contain Variable Current Of At Least 800 Ma. Minimum Exposure Time Of 1Ms To 5S. Selectable Range Of Mas Between 10 To 800 Mas Or Greater. X-Ray Tube, Fine Focus Equal To Or Less Than 0.6 Mm And Coarse Focus Equal To Or Less Than 1.2 Mm; Minimum Rotating Anode 9,700 Rpm; Minimum Anode Thermal Capacity At Least 300 Khu. Tube Must Be Branded: Canon (Toshiba), Brand And Model Of The Tube Must Be Indicated In The Proposal. Enable The Insertion Of Additional Cu Or Al Filters. System With At Least 800 Pre-Programmed Factory Techniques. Emitter Port Stand With Its Appropriate Characteristics; Column With Longitudinal Displacement From 250 Cm; Vertical Displacement Of At Least 150 Cm; Tube Rotation Around Axis +/-90 Degrees; System With Electromagnetic Brakes, Activated Through Buttons On The Front Control Of The Stand; Collimator Light Field Indication With Led Lamp And Automatic Switch Off After 30 Seconds; Distance From The Focal Point Of At Least 100 Cm. Exam Table With Floating Top With Minimum Dimensions Of 200 X 80 Cm, Minimum Longitudinal Displacement Of +/- 40 Cm, With Transverse Displacement +/-12 Cm. Top Centering Indication. Electromagnetic Braking System. Anti Diffusion Grid Of At Least 10:1 And 103 L/In. Load Capacity Supported By The Table Of At Least 200