Bids Are Invited For Hiring A Company Specialized In The Supply Of Lung Ventilators And Electric Power Generator, Proposal No. 11479.5600001240-07, According To The Specifications Contained In The Spreadsheets And Terms Of Reference - Annex I, Of The Notice.
Bids Are Invited For Hiring A Company Specialized In The Supply Of Lung Ventilators And Electric Power Generator, Proposal No. 11479.5600001240-07, According To The Specifications Contained In The Spreadsheets And Terms Of Reference - Annex I, Of The Notice.
Stationary Diesel Generator Group With Power Of 78.0 Kvas (Continuous Operating Regime / Stand-By). It Has A Three-Pole Mechanical Protection Circuit Breaker, Protection Against Short Circuit, Maximum Current And Phase Inversion. It Has A Digital Panel And Automatic Transfer Board. It Has An Electric Starting System At 12 Vdc And An Automatic Voltage Regulator (Avr). It Has An Alternator With Power Factor 0.8, Three-Phase, At Voltage 220/127 V, 60 Hz, 4 Poles, Brushless Type, Reconnectable At 220/380 Or 440 V And With Neutral Access. It Has A Diesel Engine At 1,800 Rpm, Water Cooled (Radiator), At Least 3 Cylinders In Line, Mechanical Speed Governor. It Has A Tank Attached To The Base With A Minimum Autonomy Of Up To 8 Hours, In Continuous Operation. It Has Acoustic Insulation With Acoustic Pressure At 7 Meters Between 70 And 75 Db(A). It Must Be Accompanied By: Pre-Heating System And Liquid Containment Tray At The Base, Microprocessed Electronic Lung Ventilator For Neonatal, Pediatric And Adult Patients. Have The Following Ventilation Modes Or Compatible Ventilation Modes: Volume-Controlled Ventilation; Pressure Controlled Ventilation; Synchronized Intermittent Mandatory Ventilation; Pressure Support Ventilation; Ventilation With Volume Support; Ventilation With Continuous Flow, Cycled In Time And With Limited Pressure, Including In Yes Or Guaranteed Volume Mode For Neonatal Patients; High Flow Oxygen Therapy; Two-Level Ventilation, Non-Invasive Ventilation, Including In Neonatal; Continuous Positive Airway Pressure - Cpap; Back Up Ventilation At Minimum In Spontaneous Modes; With Possibility Of Inclusion Of Proportional Ventilation Mode With Synchronization/Patient-Ventilator Adaptation For Better Respiratory Mechanics (Nava, .Smartcare, Pav, Asv, Ava) At Least For Adult/Pediatric Patients. Control System: Have Control And Adjustment For At Least The Parameters With The Ranges: Controlled Pressure Of At Least 90Cmh20 And Support Pressure Of At Least 60Cmh20; Tidal Volume Of At Least Between 5 To 2000 Ml; Respiratory Rate Of At Least 100 Rpm; Inspiratory Time Of At Least Between 0.3 To 5.0 Seconds; Peep Of At Least 40 Cmh20; Inspiratory Sensitivity Per Flow Of At Least Between 0.5 To 2.0 Ipm; Flow Adjustment For High Flow Oxygen Therapy From 2 To Minimum 50 L/Min; Fio2 From At Least 21 To 100%. Monitoring System: Color Screen Of At Least 12 Inches Touch-Screen Or Rotational Button For Parameter Programming Adjustment: Volume Monitoring By Proximal Sensor For Neonatal Patients And Proximal Or Distal For Pediatric And Adult Patients; Main Monitored Parameters: Exhaled Tidal Volume, Inspired Tidal Volume, Peak Pressure, Plateau Pressure, Peep, Total Peep, Mean Airway Pressure, Total And Spontaneous Respiratory Rate, Inspiratory Time, Expiratory Time, Fio2 With Monitoring By Sen, 03/04/2026 - 14:53:14, 03/04/2026 - 14:53:15
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.