GTR 108855786

Tenders Are Invited For Echo, Ultrasound And Doppler Imaging Equipment – Ultraljudssystem Röntgen

ICB — International Competitive Bid Closed Northern Europe
Tender Information
GTR Reference
108855786
Tendering Authority
Subscribe to view
Tender No
95925-2026
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Echo, Ultrasound And Doppler Imaging Equipment – Ultraljudssystem Röntgen
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Northern Europe
Political Region
European Union
Last Date of Bid Submission
20-03-2026 Closed
Work Detail
Echo, Ultrasound And Doppler Imaging Equipment – Ultraljudssystem Röntgen. The X-Ray Department At Östersund Hospital Intends To Procure Two (2) Ultrasound Systems, Which In Terms Of Performance Should Be In The High-End Class. The Ultrasound Systems Must Be Mobile, I.E. Allow Smooth Movement And Allow The Possibility To Carry Out Examinations Under Good Ergonomic Conditions. The Ultrasound Machines Are To Be Used In Clinical Operations At The X-Ray Department, Customary Ultrasound Examinations At A County Hospital, I.E. Patients Of All Ages And A Wide Range Of Ultrasound Methods. The Emphasis In This Procurement Is That The Machines Must Have Good Performance For Diagnostics Of Liver, Muscles, Tendons And Nerves. For The Evaluation Of Liver Fibrosis And Hepatic Steatosis, Östersund Hospital Does Not Have A Fibroscan With Cap At Any Of The Receptions, But Quantitative Non-Invasive Evaluation Of Liver Fibrosis And Hepatic Steatosis Is Entirely Relegated To The X-Ray Department With Its Ultrasound Machines. Measurements Are Mainly Carried Out On Adults But Also On Children. Therefore, Rapid Technology With High Scientific Evidence Is Required For Shear Wave Elastography And Steatosis Measurement For The Detection, Monitoring And Grading Of Liver Fibrosis In F0-F4 And Liver Steatosis In S0-S3. The Machines Must Have Shear Wave Elastography Technology For Liver And Extrahepatic Structures, And Must Be Able To Be Performed With Both Curved And Linear Probes, Including High-Frequency Hockey Sticks. Machine-Specific Reference Tables With Cut-Off For Liver Fibrosis Graded F0-F4 And Liver Steatosis Graded S0-S3 For Adults Must Be Available. With The Fusion Program, Mri And Dt Images Must Be Able To Be Transferred From Our Pacs To The Machines. Since The Machines Will Also Be Used For Training X-Ray Personnel, Great Emphasis Is Also Placed On Parameters For The Physics Of The Ultrasound Being Easily Accessible And Manually Adjustable. For The Probes In General, They Must Be Equipped With Modern Technology And Be Able To Provide Exceptionally Good Spatial Resolution For Abdominal Diagnostics, Small Parts/Testis/Thyroid, Neonatal Us, Muscles/Tendons/Nerves, Fusion, Contrast And Vascular Diagnostics. Other Functions Specified Below.
Key Value
Tender Value
4,000,000 - SEK
Tender Documents
Global Tender Document
4e247b76-4f41-4f61-8efe-77442f699f22.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders