GTR 108723260

Request For Quotation Ensuring Combat And Mobilization Readiness Of The Armed Forces Of The Republic Of Kazakhstan

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
108723260
Tendering Authority
Subscribe to view
Tender No
16261164
Financer Name
Self-Funded
Work Title
Request For Quotation Ensuring Combat And Mobilization Readiness Of The Armed Forces Of The Republic Of Kazakhstan
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
11-02-2026 Closed
Work Detail
Quantitative Test For Determining The Quantitative Determination Of Cancer Antigen 15-3 (Ca 15-3) For The Automatic Chemiluminescent Immunoanalyzer Maglumi X3 Number Of Tests In The Kit: 100 Pieces. Contents Set: Quality Control, Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanospheres Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Information About The Reagents And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks., A Set Of Starting Reagents Designed To Generate A Hnmiluminometric Light Signal, Storage Conditions Stability Starting Reagents Should Be Stored Tightly Closed In Original Bottles. Store The Reagents At A Temperature Of 15 To 30 ° C Until The Expiration Date Indicated On The Label (12 Months Of Delivery Production). Stability When Stored In The Apparatus: 4 Weeks. Reagents Must Be Protected From Direct Sunlight, Kit For Determining The Tumor Marker Of Total Psa Prostate-Specific Ag No. 100 On The Abbott Architec 1000 Analyzer, Reaction Cuvettes, At Least 120 Pcs/Pack, For The Biochemical Analyzer Urit-Ca-331A, Kf Stick 11 - Test Strip For Semi-Quantitative And Visual Determination Of Ascorbic Acid, Bilirubin, Blood, Glucose, Ketones, Leukocytes, Nitrites, Ph, Protein, Specific Gravity, Urobilinogen In Urine, Bottle No. 100 From The Kf Scan Urine Analyzer Kit, Sodium - A Set Of Reagents For Determining The Concentration Of Sodium In Biological Fluids (Enzymatic), In Bottles Adapted For The Carousel Of The Urit Analyzer - Ca-331A, (Set Composition: 4 Bottles Of 20 Ml, 2 Bottles Of 20 Ml, Calibrator 2 Of 1 Ml)., Plasma Diluent. Designed To Dilute Plasma During Research. Release Form: Liquid, Ready For Use. Determination Method: Nephelometry Or Turbidimetry. Supplied In Cardboard Packages (Pack: 1 Bottle Of 100 Ml). Storage Temperature +15 +25 C., Quantitative Test For The Determination Of Prolactin (Prl) For The Automatic Chemiluminescent Immunoanalyzer Maglumi X3. Number Of Tests In The Kit: 100 Pieces. Kit Contents: Quality Control And Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Information About The Reagents And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks., Quantitative Test For The Determination Of Thyroid-Stimulating Hormone (Tsh Or Thyrotropin) For The Automatic Chemiluminescent Immunoanalyzer Maglumi X3. Number Of Tests In The Kit: 100 Pieces. Set Contents: Level 1 Quality Control, Level 2 Quality Control And Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Information About The Reagents And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks., Kit For Determination Of Fsh On The Abbott Architec 1000 Analyzer, Раствор Триггера Для Люминисценции Исследуемого Образца. Детергент Triton X100 < 1.99%, Гидроксид Натрия < 1.4%, Дистиллированная Вода > 96.6%. Set Contents: 4 Fl. 975 Ml. No. 4, Diagnostic Reagent For Automatic Coagulometer Analyzer For Invitro Diagnostics Acl Elite/Acl Elite Pro To Determine Thrombin Time. The Reagent Must Be Recommended For Use By The Manufacturer, Iron, A Set Of Reagents For The Determination Of Iron In Serum And Blood Plasma (Method With Forrosine) In Bottles, Kit Contents: Reagent No. 1, At Least 5 Bottles (30 Ml Each), Reagent No. 2, At Least 2 Bottles (15 Ml Each), Calibrator: At Least 1 Bottle (5.0 Ml). The Determination Method And Bottles Must Be Adapted To The Biochemical Analyzer Urit-Ca-331A, Quantitative Test For The Determination Of Free Triiodothyronine (Ft3) For The Automatic Chemiluminescent Immunoanalyzer Maglumi X3 Number Of Tests In The Set: 100 Pieces. Contents Set: 1St Level Quality Control, 2Nd Level Quality Control, Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Includes An Rfid Tag Containing Reagent Information And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Two-Point Calibration Curve. Calibration Is Stable For 4 Weeks., Reagent For The Determination Of Fibrinogen Qfa According To Clauss. The Reagent Contains Purified Bovine Thrombin At A Concentration Of 100 U/Ml. Release Form: Lyophilisate. Contents Of The Kit (10 Flasks Of 5 Ml Of Reagent). Used To Work On The “Closed” System Of The Acl Elite Pro Analyzer, Quantitative Test For The Determination Of Free Prostate-Specific Antigen (F-Psa) For The Automatic Chemiluminescent Immunoanalyzer Maglumi X3. Number Of Tests In The Kit: 100 Pieces. The Kit Includes: Quality Control, Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Information About Reagents And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks., Quantitative Test For The Determination Of Vitamin B12 For The Automatic Chemiluminescent Immunoanalyzer Maglumi X3. Number Of Tests In The Set: 100 Pieces. Contents Set: 1St Level Quality Control, 2Nd Level Quality Control, Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Information About The Reagents And A Built-In Calibration Curve. Calibrators Are Used To Correct A Built-In Two-Point Calibration Curve. Calibration Is Stable For 4 Weeks., Kit For Determination Of Fsh On The Abbott Architec 1000 Analyzer, Wash Concentrate (1 Pack = 1*714 Ml). Wash Concentrate Is A Solution That, By Dilution, Is Used To Obtain A Wash Liquid Intended To Wash Out Magnetic Microparticles During Analysis Using An Automatic Chemiluminescent Immunological Analyzer, Calibrator For The Determination Of Total Psa And Prostate-Specific Ag On The Architec 1000 Analyzer
Key Value
Tender Value
5,818,328 - KZT
Tender Documents
Global Tender Document
62d92e5b-60e3-4f47-8ca2-62a739bb3579.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders