Hospital Electric Bed - 6723 - 6723 - Fawler Bed 4 Motors, Headboard/Headboard And Injected Polyethylene Rails. Removable Headboard And Footboard In High-Density Injected Polyethylene With Safety Locks. Base With Recessed Feet, Fully Covered In High-Resistance Thermoplastic Material. Tubular Structure With Carbon Steel Plates Of Different Thicknesses Designed To Meet The Efforts And Rated Load Of The Product. Chassis Consists Of A Structure Of 50 X 30 X 2.0 Mm Tubes With 1/4 Thick Plates. The Platform Is Made Up Of A 50 X 30 X 2.0 Mm Tube Structure With 3/8 Sheets. The Metal Structure Of The Beds Consists Of Four Articulated Sections Made With A Structure Of 30 X 20 X 1.2 Mm Tubes With 3/16 Sheets. Structured Thermoplastic Bed, With Patient Containment And Mattress Limiter. Fastening Made Independently In The Four Articulated Sections Of The Metal Structure Of The Bed. Bed Movements Carried Out Using Four Motors And An Adjustable System With Six Positions. The Movements Performed By The Bed Are: Fowler, Semi-Fowler Back Elevation, Leg Elevation, Raising And Lowering The Bed, Trendelemburg, Proclive, Armchair, Vascular, Cardiac And Auto Contour. Abdominal Compensation System To Avoid Compressions On The Thorax And Pelvis When Raising The Back, Equipped With Cushioning To Relieve The Fall. Mechanical Cpr For Emergency Procedures And Cardiopulmonary Resuscitation, Operated Through Side Lever On Both Sides Of The Bed With Wired Remote Control And Safety Device With Blocker. Two Pairs Of Side Rails, One Pair On The Back And One Pair On The Leg, Independently Acting, Structured With High Resistance In Injected Polyethylene, Movement Allows Them To Be Above And Below The Bed Through A Gas Piston (Cushioning) And With A Safety Lock And Spaced Between The Rails To Prevent Patient Escape. Anti-Rust Treatment, Electrostatic Powder Paint Finish, Lung Ventilator - Lung Ventilator For Adult, Pediatric And Neonatal Patients With The Following Minimum Specifications; Graphical And Numerical Monitoring Using A Tft Color Touchscreen Of At Least 12 Inches And The Presence Of An Encolder As A Second Equipment Handling Option, With Blocking Function, To Avoid Changes In Ventilator Settings; - Must Have A Transport Handle For Intra-Hospital Movement (When Disconnected From The Trolley); Distal Sensor For Adults/Pediatrics And Proximal For Neonatals;- Electrical Supply: 100 To 240 Vac, With Automatic Switching, 50/60 Hz;- Internal Rechargeable Battery With Autonomy Of At Least 180 Minutes, With The Possibility Of Using 2 Batteries, Increasing Its Capacity By Up To 300 Minutes Or Higher;- Operation Only With Oxygen Through The Hospitals Oxygen Network, Without The Need For A Compressed Air Network, Have An Alternative Source Of Compressed Air (Turbine); (Hpo) And Low Pressure (Lpo);- Must Have Software For Endotracheal Tube Or Tracheostomy Compensation;- Must Have Usb Input For Data Transfer- Must Have Data Interface Via Rs232, Vga Connector, Call
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.