Tall Steel Cabinet, With 2 Opening Doors Material Made From High Quality Carbon Steel Sheet, With A Minimum Sheet Thickness Of 24 (0.60 Mm) On The Body And Doors. Minimum Dimensions Height: 190 Cm; Width: 90 Cm; Depth: 40 Cm. Finish Anti-Rust Treatment And Electrostatic Powder Paint Finish (Epoxy), Scratch-Resistant And Easy To Clean. Color: Standard Gray Or To Be Defined By Administration. Doors And Closing Two Opening Doors, With Internal Reinforcements (Omega Type Or Similar) For Greater Rigidity. Closing By Yale-Type Cylindrical Lock Or Similar, With Duplicate Key. Recessed Or Polypropylene/Metallic Handles. Shelves Minimum Of 04 (Four) Internal Shelves (Can Be 01 Fixed And 03 Adjustable) With Reinforcement For Weight Support. Minimum Load Capacity Per Shelf Of 40 Kg (Evenly Distributed). Assembly The Cabinet Must Be Delivered Assembled And Ready For Use (Or With Assembly Service Included). Warranty Minimum Warranty Of 12 (Twelve) Months Against Manufacturing Defects., Vacuum Cleaner And Liquids (Professional Use) Vacuum Cleaner Function That Allows The Aspiration Of Dust (Solids) And Liquids (Water And Wet Waste). Reservoir Capacity Total Reservoir (Drum) Capacity Minimum 15 (Fifteen) Liters. High-Resistance Stainless Steel Or Polypropylene Material. Minimum Motor Power 1,200 W (Watts). Resources Must Have Blower Function And Swivel Wheels (Minimum 04) To Facilitate Movement. Filter Efficient Filtration System, With Washable Filter And/Or Hepa Filter (Desirable) To Retain Microparticles. Included Accessories Include At A Minimum: 1. High-Resistance Flexible Hose (Minimum 1.5M); 2. Nozzle For Corners And Gaps; 3. Upholstery Nozzle; 4. Floor Nozzle (Switchable For Dry/Liquid); 5. Extension Tubes (Minimum 02 Units). Power Supply Voltage: Automatic Bivolt (Or 220V, As Needed). Electrical Cable With A Minimum Length Of 3.0 (Three) Meters. Regulations Have An Inmetro Certification And Safety Seal And Are Manufactured In Accordance With Brazilian Standards. Minimum Warranty Of 12 (Twelve) Months Against Manufacturing Defects, Horizontal Tabletop Autoclave (Capacity Up To 75 Liters) Capacity Useful Volume Of The Sterilization Chamber Minimum Of 60 (Sixty) Liters And Maximum Of 75 (Seventy-Five) Liters. Sterilization Chamber Built In Stainless Steel (Preferably Aisi 304 Or Higher), To Guarantee High Resistance To Corrosion, Pressure And High Temperatures. Cylindrical Or Rectangular Shape. Cabinet And Finish External Cabinet In Carbon Steel With Anti-Corrosion Treatment And Finish In Electrostatic Powder Painting (Epoxy) Or Stainless Steel, Resistant And Easy To Clean. Microprocessed And Fully Automatic Operating Mode, With Digital Control Panel (Led Or Lcd/Touchscreen Display) For Control, Visualization Of Parameters And Indication Of Cycle Phases (Heating, Sterilization, Depressurization And Drying). Sterilization Cycles Minimum Of 02 (Two) Pre-Programmed Cycles (Ex: 121°C And 134°C). The Equipment Must Allow Sterilization At Temperatures Between 121°C And 134°C. Drying Efficient Drying System Using Half-Open Door With Resistance Connected Or Vacuum Drying System (If Model Is Class B/Pre-Vacuum). Must Offer Extra Dry Cycle. Safety Must Have Multiple Safety Systems, Including: Overpressure Safety Valve; Thermostat
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.