GTR 108118491
Tenders Are Invited For Medical Products For The Cobas Pro Analyzer
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
108118491
Tendering Authority
Subscribe to view
Tender No
16132703
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Medical Products For The Cobas Pro Analyzer
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
09-02-2026
Closed
Work Detail
Precicontrol Multi Marker Control For The Cobas Pro Analyzer Purpose: The Precicontrol Multimarker Kit Is Intended For Quality Control Of The Listed Immunotests On Elecsys And Cobas E Analyzers. The Precicontrol Multimarker Kit Contains A Lyophilized Control Serum Based On An Equine Serum Matrix In Two Concentration Ranges. Controls Are Used To Monitor The Accuracy And Precision Of Elecsys Immunoassays. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Pc Mm1: 3 Bottles, Each With 2.0 Ml Of Control Serum ▪ Pc Mm2: 3 Bottles, Each With 2.0 Ml Of Control Serum. To Prepare The Control Material, It Is Necessary To Add Distilled Water. Storage And Stability Store At 2‑8 °C. Lyophilized Control Serum Is Stable Until The Stated Expiration Date. Stability Of All Components In Dissolved Control Serum: At -20 °C (± 5 °C) 31 Days Or At 2-8 °C 72 Hours, On Board Analyzers At 20-25 °C Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Solution For Measuring Ecl - Procell Ii M For The Cobas Pro Analyzer Procell M Solution For The Cobas 6000 2X2 L Analyzer. Purpose: System Solution For Generating Electrochemical Signals In The Immunological Analyzers Modular Analytics E170, Cobas E 601 And Cobas E 602. Reagents And Working Solutions: 2 X 2 L System Buffer Phosphate Buffer 300 Mmol/L, Tripropylamine 180 Mmol/L; Detergent ≤ 0.1%; Preservative, Ph 6.8. Storage And Transportation Conditions: Store At Room Temperature Strictly In An Upright Position. Shelf Life At 15-25 °C See Expiration Date On Kit Label. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Prolactin Calibrator For The Cobas Pro Analyzer For 300 Determinations Purpose: The Prolactin Ii Calset Calibrator Set Is Designed For Calibrating The Elecsys Prolactin Ii Quantitative Test On The Elecsys And Cobas E Immunochemical Analyzers. Prolactin Ii Calset Is A Lyophilized Buffered Horse Serum Matrix With Added Recombinant Prolactin In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Prl Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Prl Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Expiration Date Indicated. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 3 Months, On Board Analyzers At 20-25 °C Use Only Once. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Pth Calibrator For The Cobas Pro Analyzer Purpose: The Calset Pth Calibration Kit Is Intended For Calibration Of The Elecsys Pth Quantitative Analysis For The Determination Of Intact Pth (Parathyroid Hormone) On The Elecsys And Cobas E Immunochemical Analyzers. The Calset Pth Calibration Kit Consists Of Lyophilized Human Serum With The Addition Of Synthetic Pth In Two Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions (Allowable Error Of 3% Of The Declared Volume): ▪ Pth Cal1: 2 Bottles, Each With 1.0 Ml Of Calibrator 1 ▪ Pth Cal2: 2 Bottles, Each With 1.0 Ml Of Calibrator 2. Pth (Synthetic Peptide, Human Sequence) In Two Concentration Ranges (Approximately 1 Pmol/L Or 10 Pg/Ml And Approximately 466 Pmol/L Or 4400 Pg/Ml) In A Human Serum Matrix; Preservative To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Refurbished Calibrators: At -20 °C ± 5 °C 12 Weeks, At 2‑8 °C 14 Days, On Board The Cobas E 411 Analyzer At 20‑25 °C Up To 6 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, C.F.A.S Proteins Calibrator For Cobas Pro Analyzer Purposec.F.A.S. Proteins Is Designed To Calibrate Roche Quantitative Methods When Working With Roche Biochemical Analyzers In Accordance With Value Sheets. Preparation Of The Reagent Working Solution The Product Is Ready For Use. Stir Carefully Before Use. Avoid Foam Formation. The Supplied Barcode Labels Are Intended Solely For Calibrator Identification On Roche/Hitachi Modular Automated Analyzers And Cobas C Systems. Attach Barcode Labels To Tubes Containing Calibrator Cups. Storage And Stability Store At 2‑8°C. Roche Stability Criterion: Measurement Results Within ± 10% Of Baseline. Stability: Before Opening: Until The End Of The Indicated Shelf Life At 2‑8 °C. After Opening: For 4 Weeks Of Storage At A Temperature Of 2‑8 °C, Provided That The Dissolution Of The Calibrator Occurs Without Microbial Contamination, I.E. By Pouring Them Into Another Container. Store The Calibrator In A Tightly Sealed Container When Not In Use. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Lh Calibrator For The Cobas Pro Analyzer Purpose: The Lh Calset Ii Calibrator Set Is Intended For Calibration Of The Elecsys Lh Quantitative Test On The Elecsys And Cobas E Immunochemical Analyzers. Lh Calset Ii Is A Lyophilized Matrix Of Human Blood Serum With Added Human Lh In Two Concentrations. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Lh Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 In Each ▪ Lh Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 In Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 3 Months, On Board Analyzers At 20‑25 °C For Single Use Only. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Reference Electrode - Reference Electrode For The Cobas Pro Analyzer An Assembled Reference Electrode Is Used For Electrical Communication Between The Sample And The “Ground” (Zero Phase). Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, C.F.A.S. Lipids (Calibrator For Automatic Systems) Is Used For Calibration In The Quantitative Determination Of Lipids On Roche Analyzers For Clinical Chemistry According To The Assigned Values Indicated In The Data Sheets. Preparation Of A Working Reagent Solution. Carefully Open One Bottle, Avoiding Loss Of Lyophilisate, And Pipette It Into 1.0 Ml Distilled/Deionized Water. Carefully Close The Bottle And Wait Until The Ingredients Are Completely Dissolved, Stirring Them In A Circular Motion For 30 Minutes. Avoid Foam Formation. Storage And Stability Store At 2‑8 °C. Stability Criterion Used By Roche. Measurement Results Within ± 10% Of The Original Level. Stability Of Lyophilized Calibrator At 2‑8 °C: Until The End Of The Shelf Life. Stability Of Dissolved Calibrator Components: At 15‑25 °C 8 Hours, At 2‑8 °C 5 Days, At (-15)‑(-25) °C 4 Weeks (With Single Freezing). Store The Calibrator In A Tightly Sealed Container When Not In Use. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Calibrator C.F.A.S. Pac For Cobas Pro Analyzer Purpose C.F.A.S. Pac (Prealbumin-Antistreptolysin O-Ceruloplasmin) Is Intended For Calibration Of Roche Quantitative Methods When Working With Roche Biochemical Analyzers In Accordance With Value Sheets. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Clinchem Multi 2 Control For Cobas Pro Analyzer Purpose: The Precicontrol Clinchem Multi 2 Kit Is Intended For Use During Quality Control Procedures, As It Allows You To Determine The Accuracy Of Quantitative Methods Specified In Special Documents. The Package Contains 20 Vials Of Lyophilized Control Material To Prepare 5 Ml Of Liquid Control Each. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Universal Control For The Cobas Pro Analyzer Purpose: A Set Of Precicontrol Universal Control Materials Is Used To Control The Quality Of Elecsys Immunotests On The Elecsys And Cobas E Immunochemical Analyzers. Precicontrol Universal Is A Lyophilized Control Serum Based On Human Serum In Two Concentration Ranges. Control Materials Are Used To Monitor The Accuracy And Precision Of Elecsys Immunoassays. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Pc U1: 2 Bottles, For 2 X 3.0 Ml Of Control Serum (Human) ▪ Pc U2: 2 Bottles, For 2 X 3.0 Ml Of Control Serum (Human). To Prepare Control Materials, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Control Serum Is Stable Until The Indicated Expiration Date. Stability Of All Components In Reconstituted Control Serum: At -20 °C (± 5 °C) 1 Month, At 2‑8 °C For 3 Days, On Board Analyzers At 20‑25 °C For Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, N-Mid Osteocalcin Calibrator For The Cobas Pro Analyzer Purpose: The N-Mid Osteocalcin Calset Calibrator Set Is Intended For Calibrating The Elecsys N-Mid Osteocalcin Quantitative Test On The Elecsys And Cobas E Immunochemical Analyzers. The N‑Mid Osteocalcin Calset Is Lyophilized Human Serum With Added Osteocalcin In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Osteoc Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Osteoc Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. Osteocalcin (Synthetic Peptide, Human Sequence) In Two Concentration Ranges (About 0 Ng/Ml And About 280 Ng/Ml) In A Human Serum Matrix. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 3 Months, At 2‑8 °C 1 Week, On Board The Cobas E 411 Analyzer At 20‑25 °C Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Nse Calset Calibrator For Cobas Pro Analyzer Purpose: The Nse Calset Calibrator Set Is Designed For Calibration Of The Elecsys Nse Quantitative Test On Cobas E Immunochemical Analyzers. Nse Calset Is A Lyophilized Buffer/Protein Matrix With Added Nse In 2 Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Nse Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Nse Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. Nse (Human) In 2 Concentration Ranges (About 0.5 Ng/Ml And About 50 Ng/Ml) In A Buffer/Protein (Bovine Serum Albumin) Matrix, Sodium Azide < 1% (M/M). To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At 2‑8 °C 6 Weeks, On Board The Cobas E 411 Analyzer At 20‑25 °C Up To 3 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Clinchem Multi 1 Control For The Cobas Pro Analyzer Purpose: The Precicontrol Clinchem Multi 1 Kit Is Intended For Use During Quality Control Procedures, As It Allows You To Determine The Accuracy Of Quantitative Methods Specified In Special Documents. The Package Contains 20 Vials Of Lyophilized Control Material To Prepare 5 Ml Of Liquid Control Each. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Progesterone Calset Calibrator For The Cobas Pro Analyzer Purpose: The Progesterone Iii Calset Calibration Kit Is Intended For Calibration Of The Elecsys Progesterone Iii Quantitative Analysis On The Elecsys And Cobas E Immunochemical Analyzers. The Progesterone Iii Calset Consists Of Lyophilized Human Serum Supplemented With Progesterone In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Prog Iii Cal1: 2 Bottles, For Preparing Calibrator 1 Each, 1.0 Ml ▪ Prog Iii Cal2: 2 Bottles, For Preparing Calibrator 2, Each 1.0 Ml. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At –20 °C (± 5 °C) 31 Days, At 2‑8 °C 24 Hours, On Board Analyzers At 20‑25 °C Use Only Once. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Preciset Rf Calibrator For Cobas Pro Analyzer Purpose Preciset Rf Is Intended For Calibration Of Roche Quantitative Methods When Working With Roche Biochemical Analyzers In Accordance With Value Passports. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume) Reactive Components: Rf In Human Blood Serum Non-Reactive Components: Hepes Buffer, Bovine Serum Albumin, Sodium Chloride, Preservative. Component Concentrations Are Specific To Each Lot. The Exact Calibrator Values Are Given In The Electronically Available Or Attached Value Sheets. The Values Are Also Encoded In The Supplied Calibrator Barcode Tables For The Roche/Hitachi Modular And Cobasc Analyzers. Preparation Of Working Solution The Product Is Ready For Use. Stir Carefully Before Use. Avoid Foaming. The Supplied Barcode Labels Are Intended Solely For Calibrator Identification On Roche/Hitachi Modular Automatic Analyzers And Cobas C Systems. Attach Barcode Labels To The Tubes Containing The Calibrator Plates. Storage And Stability Store At 2‑8 °C. Roche Stability Criterion: Recovery Within ± 10% Of Initial Value. Stability: Unopened: Until The End Of The Stated Shelf Life At 2‑8 °C. Once Opened: 24 Hours At 15-25°C Or 30 Days At 2-8°C, Provided The Calibrator Is Divided In A Manner That Prevents Microbial Contamination, Such As By Transferring Into Another Container. Do Not Freeze. Store Calibrators In Tightly Sealed Vials When Not In Use. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Cassette For Determining Rheumatoid Factor (Rf-Ii) For The Cobas Pro Analyzer For 400 Determinations Purpose: Kit For In Vitro Diagnostics. Designed For The Quantitative Determination Of Rheumatoid Factor (Rf‑Ii) In Human Serum And Plasma On Roche/Hitachi Cobas C Analyzers. The Measurements Can Be Used To Help Diagnose Rheumatoid Arthritis. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume) R1 Glycine Buffer: 170 Mmol/L, Ph 8.0; Polyethylene Glycol: 0.05%; Bovine Serum Albumin; Stabilizer; Preservative R2 Latex Particles Coated With Human Igg; Glycine Buffer Solution: 170 Mmol/L, Ph 7.3; Stabilizers, Preservatives R1 Is In Position B, R2 Is In Position C. The Reagent Is Ready For Use. Storage And Stability Rf‑Ii Shelf Life At 2‑8 °C: See Expiration Date On Cobas C Cassette Label. Shelf Life Of The Opened Reagent In The Refrigerator On Board The Analyzer: 8 Weeks. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Precicontrol Lung Cancer Cobas Pro Control Serum Kit Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Scc Calset Calibrator For Cobas Pro Analyzer Purpose The Scc Calset Calibrator Set Is Designed For Calibrating The Elecsys Scc Quantitative Test On Cobas E Immunochemical Analyzers. Theoretical Background Scc Calset Is A Lyophilized Matrix Of Human Serum With Added Pkk Protein (Recombinant, E. Coli) In 2 Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume) ▪ Scc Cal1: 2 Bottles, For The Preparation Of 1.0 Ml Of Calibrator 1 Each ▪ Scc Cal2: 2 Bottles, For The Preparation Of 1.0 Ml Of Calibrator 2 Each Pcc (Recombinant, E. Coli) In 2 Concentration Ranges Storage And Stability Store At 2-8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At –20 °C (± 5 °C) 28 Days (Only One-Time Freezing Is Allowed) At 2 8 °C 28 Days At 20 25 °C 8 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Shbg Calibrator For Cobas Pro Analyzer Purpose: The Shbg Calset Calibrator Set Is Designed For Calibrating The Elecsys Shbg Quantitative Test On Cobas E Immunochemical Analyzers. Theoretical Background The Shbg Calset Calibrator Set Is A Lyophilized Horse Serum (Shbg Cal1) And Human Serum (Shbg Cal2). Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume) ▪ Shbg Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Shbg Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each The Concentration Of Shbg Cal1 Is About 0 Nmol/L; Shbg Cal2 Contains Approximately 40 Nmol/L Human Shbg In The Human Serum Matrix. Storage And Stability Store At 2 - 8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 2 Months (Only One Time Freezing Is Allowed) On Board Analyzers At 20 - 25 °C Use Only Once Expiration Date: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Sample Cups 2 Ml. 5000 Pcs For Cobas Pro Analyzer. Single Pink Cup For Samples, Calibrators, Controls For The Cobas Pro Analyzer, Ise Standard High - Ise Standard High For The Cobas Pro Analyzer Purpose Ise Standard High Is Intended For Use In The Calibration Of Ion Selective Electrodes On Roche/Hitachi And Cobas C Analyzers. Ise Standard High Is A Water-Based Formulation With Gravimetrically Determined Electrolyte Levels. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume) 10 Ampoules Of 3 Ml Each Active Components: 160 Mmol/L Na +, 7 Mmol/L K +, 120 Mmol/L Cl. Storage And Stability Store At 15‑25 °C. Stability: Before Opening: Until The End Of The Indicated Shelf Life At 15‑25 °C After Opening: Opened Ampoules Should Be Used Immediately. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Ise Standard Low - Ise Standard Low For The Cobas Pro Analyzer Intended Use Ise Standard Low Is Intended For Use In The Calibration Of Ion Selective Electrodes On Roche/Hitachi And Cobas C Analyzers. Ise Standard Low Is An Aqueous Formulation With Gravimetrically Determined Electrolyte Levels. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume) 10 Ampoules Of 3 Ml Reactive Components: 120 Mmol/L Na+, 3 Mmol/L K +, 80 Mmol/L Cl. Storage And Stability Store At 15‑25 °C. Stability: Before Opening: Until The End Of The Indicated Shelf Life At 15‑25 °C After Opening: Opened Ampoules Should Be Used Immediately. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Ise Washing Solution - Ise Cleaning Solution For The Cobas Pro Analyzer Purpose: For Cleaning Ise Analytical Units On Roche/Hitachi Analyzers. For Cleaning Elecsys And Cobas E Immunochemical Analyzers. Ise Cleaning Solution / Elecsys Sysclean Is An Alkaline Cleaning Solution With Antimicrobial Properties. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): 5 Bottles, Each 100 Ml. Ingredients: Sodium Hydroxide, 3 Mol/L Sodium Hypochlorite Solution (< 2% Available Chlorine), Additive. Ready To Use. Storage And Stability: Store Away From Light. The Solution Is Stable Until The End Of The Stated Shelf Life When Stored At 2‑8 °C. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Il-6 Calset Calibrator For The Cobas Pro Analyzer Purpose: The Il-6 Calset Calibrator Set Is Intended For Calibrating The Elecsys Il-6 Quantitative Test On Cobas E.Il-6 Immunochemical Analyzers. Il-6 Calset Is A Lyophilized Matrix Of Horse Serum With Recombinant Il-6 Added To It In 2 Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Il‑6 Cal1: 2 Bottles, For Preparing 2.0 Ml Of Calibrator 1 Each ▪ Il‑6 Cal2: 2 Bottles, For Preparing 2.0 Ml Of Calibrator 2 Each. Il-6 (Human, Recombinant) In 2 Concentration Ranges (About 18 Pg/Ml And About 700 Pg/Ml) In A Horse Serum Matrix. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The End Of The Indicated Expiration Date. Stability Of Dissolved Calibrators: At –20 °C (± 5 °C) 3 Months, At 2‑8 °C Up To 5 Hours, On Board Analyzers At 20‑25 °C Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Ise Diluent - Ise Diluent For Cobas Pro Analyzer Sample Diluent. Used In Ise Modules Of The Cobas Pro System. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): Nacl Solution. The Package Contains 2 Bottles Of 2 Liters Of Solution Each. Storage And Stability Storage: At 15‑25 °C Until The Stated Expiration Date. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Ise Internal Standard - Ise Internal Standard For The Cobas Pro Analyzer Buffer Solution For Measuring A Blank Sample And Checking The Measuring System Of The Ise Module Before Each Measurement. Used In Ise Modules Of The Cobas Pro System. The Package Contains 2 Bottles Of 2 Liters Of Solution Each. Storage And Stability Storage: At 15‑25 °C Until The Stated Expiration Date. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Ise Reference - Ise Reference Electrolyte Electrolyte For The Cobas Pro Analyzer Buffer Solution For Filling And Activating The Reference Electrode. Used In Ise Modules Of The Cobas Pro System. Reagents - Working Solutions (Allowable Error Is 3% Of The Declared Volume): Kcl Solution. The Package Contains 2 Bottles Of 2 Liters Of Solution Each. Storage And Stability Storage: At 15‑25 °C Until The Stated Expiration Date. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Insulin Calset Calibrator For The Cobas Pro Analyzer Purpose: The Insulin Calset Calibrator Set Is Designed For Calibrating The Elecsys Insulin Quantitative Test On The Elecsys And Cobas E Immunochemical Analyzers. The Insulin Calset Is Lyophilized Bovine Serum With Added Insulin In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Insulin Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ Insulin Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 3 Months, On Board Analyzers At 20-25 °C Use Only Once. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Homocysteine Control Kit For Cobas Pro Analyzer, Ige Calset Calibrator For Cobas Pro Analyzer For 300 Determinations, Vitamin D Total Control For The Cobas Pro Analyzer Purpose: A Set Of Precicontrol Vitamin D Total Iii Control Materials Is Used To Control The Quality Of The Elecsys Vitamin D Total Iii Immunotest On Cobas E Immunochemical Analyzers. Precicontrol Vitamin D Total Iii Is A Lyophilized Control Serum Based On Human Serum In Two Concentration Ranges. Control Materials Are Used To Monitor The Accuracy Of The Elecsys Vitamin D Total Iii Immunoassay. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Pc Vitdt1: 3 Bottles, Each For Preparing 1.0 Ml Of Control Serum. Human Blood Serum; Preservative Target Value Approximately 20 Ng/Ml (50 Nmol/L) ▪ Pc Vitdt2: 3 Bottles, Each To Prepare 1.0 Ml Control Serum. Human Blood Serum; Preservative The Target Value Is About 40 Ng/Ml (100 Nmol/L). To Prepare Controls, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Control Serum Is Stable Until The Stated Expiration Date. Stability Of Dissolved Control Serum: At -20 °C (± 5 °C) 31 Days, At 2‑8 °C 72 Hours, On Board Analyzers At 20‑25 °C Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Anti-Hbs Control For The Cobas Pro Analyzer Purpose: Precicontrol Anti-Hbs Control Material Is Used To Control The Quality Of The Elecsys Anti-Hbs Ii Immunoassay On Cobas E Immunochemical Analyzers. Precicontrol Anti-Hbs Is A Ready-To-Use Control Serum Based On Human Blood Serum In The Negative And Positive Concentration Ranges. Control Materials Are Used To Monitor The Accuracy Of The Elecsys Anti-Hbs Ii Immunoassay. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Pc A‑Hbs1: 8 Bottles, 1.3 Ml Of Control Serum In Each. Human Blood Serum Negative For Anti‑Hbs; Preservative Target Concentration Range For Anti‑Hbs: ≤ 5 Iu/L▪ Pc A‑Hbs2: 8 Bottles, 1.3 Ml Of Control Serum In Each Anti‑Hbs Antibody (Human) About 100 Iu/L In Human Serum; Preservative Target Concentration Range For Anti-Hbs Antibodies: 60-150 Iu/L. Control Materials Are Supplied Ready For Use In Bottles Compatible With The System. Storage And Stability Store At 2‑8 °C. Stability: Unopened At 2‑8 °C Until Expiration Date, After Opening At 2‑8 °C For 8 Weeks, On Board The Cobas E 411 Analyzer At 20‑25 °C For Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Syphilis Control For The Cobas Pro Analyzer Purpose: Precicontrol Syphilis Control Material Is Intended For Quality Control Of The Elecsys Syphilis Immunotest On Cobas E Immunochemical Analyzers. Precicontrol Syphilis Control Material Is A Lyophilized Control Serum Based On Human Blood Serum. Control Materials Are Used To Monitor The Accuracy Of The Elecsys Syphilis Immunoassay. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Pc Syph1: 2 Bottles, Each For 2.0 Ml Of Control Serumhuman Blood Serum Negative For Antibodies To Treponema Pallidum; Preservative Target Value For Cutoff Index: About 0.15▪ Pc Syph2: 2 Bottles, Each For 2.0 Ml Control Serum. Human Serum Positive For Antibodies To Treponema Pallidum; Preservative Target Value For Threshold Index: Around 5.00. To Prepare Controls, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Control Serum Is Stable Until The Stated Expiration Date. Stability Of Dissolved Control Serum: At –20 °C (± 5 °C) 6 Months, At 2‑8 °C 28 Days, On Board Analyzers At 20‑25 °C Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Anti-Hbc Control For The Cobas Pro Analyzer Purpose: The Precicontrol Anti-Hbc Igm Control Kit Is Used To Control The Quality Of The Elecsys Anti-Hbc Igm Immunoassay On Cobas E Immunochemical Analyzers. Precicontrol Anti‑Hbc Igm Is A Ready-To-Use Control Serum Based On Human Serum In The Negative And Positive Concentration Ranges. Control Materials Are Used To Monitor The Accuracy Of The Elecsys Anti‑Hbc Igm Immunoassay. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Pc A‑Hbcigm1: 8 Bottles, 1.0 Ml Of Control Serum In Eachhuman Blood Serum Negative For Anti‑Hbc Antibodies Of The Igm Class; Preservative Target Range For Cutoff Index: 0-0.3 For Cobas E 411 Analyzer, 0-0.2 For Cobas E 402, Cobas E 601, Cobas E 602 And Cobas E 801 Analyzers.▪ Pc A-Hbcigm2: 8 Bottles, 1.0 Ml Of Control Serum Each. Anti-Hbc Igm Antibodies (Human) > 130 U/Ml (Paul Ehrlich Institute Units) In Human Serum; Preservative Target Value For Threshold Index: Around 2.50. Control Materials Are Supplied In Ready-To-Use Vials Compatible With The System. Storage And Stability: Store At 2‑8 °C. Stability: Unopened At 2‑8 °C Until The Expiration Date, After Opening At 2‑8 °C For 8 Weeks, On Board Analyzers At 20‑25 °C For Up To 6 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Cassette For Determining Total Triiodothyronine - T3 For The Cobas Pro Analyzer For 300 Determinations Purpose: Immunotest For In Vitro Diagnostics. Designed For The Quantitative Determination Of Total Triiodothyronine In Human Serum And Plasma. The Electrochemiluminescent Immunotest Is Intended For Use On Cobas E Immunochemical Analyzers. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): The Reagent Cassette Is Marked As T3. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 12 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-T3-Ab~Ru(Bpy) (Gray Cap), 1 Vial, 16 Ml: Polyclonal Anti-T3 Antibody (Sheep), Labeled With Ruthenium Complex, 75 Ng/Ml; Ans 0.8 Mg/Ml; Phosphate Buffer 100 Mmol/L, Ph 7.4; Preservative R2 T3~Biotin (Black Cap), 1 Bottle, 16 Ml: Biotinylated T3 3 Ng/Ml; Ans 0.8 Mg/Ml; Phosphate Buffer 100 Mmol/L, Ph 7.4; Preservative The Reagents Are Ready For Use, Supplied In A Cassette And Should Not Be Separated. Storage And Stability: Store At 2‑8 °C. Do Not Freeze. Stability: Unopened At 2‑8 °C Until The End Of The Shelf Life. Opened At 2‑8 °C 12 Weeks, On Board The Analyzer 8 Weeks. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, T4 Calibrator For Cobas Pro Analyzer Purpose: The T4 Calset Calibrator Set Is Designed For Calibrating The Elecsys T4 Quantitative Test On Cobas E Immunochemical Analyzers. T4 Calset Is A Lyophilized Buffer/Protein Matrix With Added L‑Thyroxine In 2 Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions (Allowable Error Of 3% Of The Declared Volume): ▪ T4 Cal1: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 1 ▪ T4 Cal2: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 2. L‑Thyroxine In 2 Concentration Ranges (About 50 Nmol/L Or 3.9 Μg/Dl And About 230 Nmol/L Or 17.9 Μg/Dl) In A Buffer/Protein (Bovine Serum Albumin) Matrix. Calibrators Are Supplied Ready For Use In Bottles Compatible With The System. Storage And Stability: Store At 2‑8 °C. Stability: Unopened At 2‑8°C Until Expiration Date, Once Opened/In Aliquots At 2‑8°C For 12 Weeks, On Board The Cobas E 411 Analyzer At 20‑25°C For Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Testosterone Ii Calset Calibrator For The Cobas Pro Analyzer Purpose: The Testosterone Ii Calset Ii Calibration Kit Is Intended For Calibrating The Elecsys Testosterone Ii Quantitative Test On The Elecsys And Cobas E Immunochemical Analyzers. Testosterone Ii Calset Ii Consists Of Lyophilized Human Serum Supplemented With Testosterone In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Testo Cal1: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 1▪ Testo Cal2: 2 Bottles, Each Containing 1.0 Ml Of Calibrator 2. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Refurbished Calibrators: At -20 °C (± 5 °C) 3 Months, On Board Analyzers At 20‑25 °C Use Only Once. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, T3 Calibrator For The Cobas Pro Analyzer Purpose: The T3 Calset Calibrator Set Is Designed For Calibration Of The Elecsys T3 Quantitative Test On Cobas E Immunochemical Analyzers. The T3 Calset Calibrator Set Is Lyophilized Human Blood Serum With Added T3 In 2 Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ T3 Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each ▪ T3 Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. T3 In 2 Concentration Ranges (About 1.25 Nmol/L Or 0.8 Ng/Ml And About 8.5 Nmol/L Or 5.5 Ng/Ml) In The Human Serum Matrix. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At 2‑8 °C 8 Weeks, On Board The Cobas E 411 Analyzer At 20‑25 °C Up To 5 Hours. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Cassette For Determining Total Thyroxine - T4 For The Cobas Pro Analyzer For 300 Determinations Purpose: Immunotest For In Vitro Diagnostics. Designed For The Quantitative Determination Of Thyroxine In Human Serum And Plasma. The Electrochemiluminescent Immunotest Is Intended For Use On Cobas E Immunochemical Analyzers. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): The Reagent Cassette Is Marked As T4. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 12 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-T4-Ab~Ru(Bpy) (Gray Cap), 1 Vial, 18 Ml: Polyclonal Anti-T4 Antibody (Sheep), Labeled With Ruthenium Complex, 100 Ng/Ml; Ans 1 Mg/Ml; Phosphate Buffer 100 Mmol/L, Ph 7.4; Preservative R2 T4~Biotin (Black Cap), 1 Bottle, 18 Ml: Biotinylated T4 20 Ng/Ml; Phosphate Buffer 100 Mmol/L, Ph 7.4; Preservative The Reagents Are Ready For Use, Supplied In A Cassette And Should Not Be Separated. Storage And Stability: Store At 2‑8 °C. Do Not Freeze. Stability: Unopened At 2‑8 °C Until Expiration Date Indicated, Unopened At 2‑8 °C 12 Weeks, On Board Analyzer 8 Weeks. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Tg Ii Calset Calibrator For Cobas Pro Analyzer Purpose: Tg Ii Calset Is Intended For Calibration Of The Elecsys Tg Ii Quantitative Analysis On Cobas E Immunochemical Analyzers. The Tg Ii Calset Consists Of Lyophilized Horse Serum Supplemented With Thyroglobulin In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions: ▪ Tg 2 Cal1: 2 Bottles, For Preparing Calibrator 1, Each 1.0 Ml ▪ Tg 2 Cal2: 2 Bottles, For Preparing Calibrator 2, Each 1.0 Ml. Thyroglobulin (Human) In Two Concentrations (About 0.15 Ng/Ml And About 180 Ng/Ml) In A Horse Serum Matrix. To Prepare Calibrators, It Is Necessary To Add Distilled Water. Storage And Stability Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Refurbished Calibrators: At -20 °C (±5 °C) 93 Days, At 2-8 °C 21 Days, On Board The Cobas E 411 Analyzer At 20-25 °C Up To 5 Hours. Upon Delivery, Present A Certificate Of Origin Of The Goods And A Power Of Attorney From The Manufacturer To Sell The Goods On The Territory Of The Republic Of Kazakhstan. Reagents For The Cobas E411 Analyzer. Delivery Area: For Eu Countries. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Total Psa Ii Calset Calibrator For The Cobas Pro Analyzer For 1000 Determinations Purpose: The Total Psa Calset Ii Calibrator Set Is Intended For Calibrating The Elecsys Total Psa Quantitative Test On Cobas E.Total Psa Calset Ii Immunochemical Analyzers Is Lyophilized Human Blood Serum By Adding Human Prostate-Specific Antigen (Psa) In Two Concentrations. The Calibrator Set Can Be Used. With All Lots Of Reagents. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Psa Cal1: 2 Bottles, To Obtain 1.0 Ml Of Calibrator 1 Each▪ Psa Cal2: 2 Bottles, To Obtain 1.0 Ml Of Calibrator 2 Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 12 Weeks, At 2‑8 °C 6 Weeks, On Board The Cobas E 411 Analyzer At 20‑25 °C Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Thyroab Control For The Cobas Pro Analyzer Purpose: The Precicontrol Thyroab Control Set Is Used To Control The Quality Of The Elecsys Anti‑Tshr, Anti‑Tpo And Anti‑Tg Immunoassays On The Elecsys And Cobas E Immunochemical Analyzers. Precicontrol Thyroab Is A Lyophilized Control Serum Based On A Human Serum Matrix In Two Concentration Ranges. Control Materials Are Used To Monitor The Accuracy And Precision Of The Elecsys Anti‑Tshr, Anti‑Tpo And Anti‑Tg Immunoassays. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Pc Thyro1: 2 Bottles, For Preparing 2.0 Ml Of Control Serum Each ▪ Pc Thyro2: 2 Bottles, For Preparing 2.0 Ml Of Control Serum Each. To Prepare The Control Material, It Is Necessary To Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Control Serum Is Stable Until The Stated Expiration Date. Stability Of All Components In Dissolved Control Serum: At -20 °C (± 5 °C) 1 Month Or At 2‑8 °C For 3 Days, On Board The Analyzers At 20‑25 °C For Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Tsh Calset Calibrator For The Cobas Pro Analyzer Purpose: The Tsh Calset Calibration Kit Is Intended For Calibration Of The Elecsys Tsh Quantitative Analysis On Cobas E. Tsh Calset Immunochemical Analyzers Consists Of A Horse Blood Serum Matrix (Tsh Cal1) And A Human Blood Serum Matrix With Human Tsh (Tsh Cal2) In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Tsh Cal1: 2 Bottles, Each Containing 1.3 Ml Of Calibrator 1 ▪ Tsh Cal2: 2 Bottles, Each Containing 1.3 Ml Of Calibrator 2. Calibrators Are Supplied Ready For Use In Bottles Compatible With The System. Storage And Stability: Store At 2‑8 °C. Stability: Unopened At 2‑8 °C Until Expiration Date, Once Opened/In Aliquots At 2‑8 °C For 12 Weeks, On Board The Cobas E 411 Analyzer At 20‑25 °C For Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Varia Control For The Cobas Pro Analyzer Purpose: A Set Of Precicontrol Varia Control Materials Is Used To Control The Quality Of The Corresponding Elecsys Immunoassays On The Elecsys And Cobas E Immunochemical Analyzers. Precicontrol Varia Is A Lyophilized Control Serum Based On Human Serum In Two Concentration Ranges. Control Materials Are Used To Monitor The Accuracy And Precision Of Elecsys Immunoassays. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ Pc V1: 2 Bottles, Each For 3.0 Ml Of Control Serum ▪ Pc V2: 2 Bottles, Each For 3.0 Ml Of Control Serum. To Prepare The Control Material, It Is Necessary To Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Control Serum Is Stable Until The Indicated Expiration Date. Stability Of Components In Reconstituted Control Serum: At -20 °C (± 5 °C) For 31 Days Or At 2‑8 °C For 72 Hours, On Board Analyzers At 20‑25 °C For Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Tumor Marker Control For The Cobas Pro Analyzer Purpose: The Precicontrol Tumor Marker Kit (Set Of Control Sera) Is Intended For Quality Control Of Elecsys Tests Using The Immunochemical Method On Elecsys And Cobas E Analyzers. Precicontrol Tumor Marker Control Material Is A Lyophilized Control Serum Based On Human Serum With Concentrations In 2 Clinically Relevant Ranges. Control Materials Are Used To Monitor The Accuracy And Precision Of Elecsys Immunoassays. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume) ▪ Pc Tm1: 2 Bottles, Each For 3.0 Ml Of Control Serum (Human) ▪ Pc Tm2: 2 Bottles, Each For 3.0 Ml Of Control Serum (Human). To Prepare The Control Material, It Is Necessary To Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Control Serum Is Stable Until The Stated Expiration Date. Stability Of Components In Dissolved Control Serum: At -20 °C (± 5 °C) For 1 Month Or At 2‑8 °C For 2 Weeks, On Board Analyzers At 20‑25 °C For Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Vitamin B12 Calibrator For The Cobas Pro Analyzer Purpose: Vitamin B12 Ii Calset Is Intended For Calibration Of The Elecsys Vitamin B12 Ii Quantitative Analysis On The Elecsys And Cobas E Immunochemical Analyzers. Vitamin B12 Ii Calset Is A Lyophilized Human Serum Matrix With The Addition Of Vitamin B12 In Two Concentration Ranges. The Calibrator Set Can Be Used With All Reagent Lots. Reagents - Working Solutions (Acceptable Error Is 3% Of The Declared Volume): ▪ B12 Ii Cal1: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 1 Each▪ B12 Ii Cal2: 2 Bottles, For Preparing 1.0 Ml Of Calibrator 2 Each. To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability: Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Dissolved Calibrators: At -20 °C (± 5 °C) 84 Days, At 2‑8 °C 72 Hours, On Board Analyzers At 20‑25 °C Use Only Once. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Vitamin D Total Calibrator For The Cobas Pro Analyzer Purpose: The Vitamin D Total Calset Calibration Set Is Intended For Calibrating The Elecsys Vitamin D Total Quantitative Analysis On The Elecsys And Cobas E Immunochemical Analyzers. Vitamin D Total Calset Matrix Is A Lyophilized Matrix Of Human Serum With The Addition Of 25‑Oh Vitamin D3 In Two Concentration Ranges. Calset Can Be Used With All Reagent Lots. Reagents - Working Solutions (Allowable Error Of 3% Of The Declared Volume): ▪ Vit‑D Total Cal1: 2 Bottles, Each With 1.0 Ml Of Calibrator 1 ▪ Vit‑D Total Cal2: 2 Bottles, Each With 1.0 Ml Of Calibrator 2. 25‑Oh Vitamin D3 In Two Concentration Ranges (Approximately 3 Ng/Ml Or 7.5 Nmol/L And Approximately 45 Ng/Ml Or 113 Nmol/L) In Human Serum Matrix; Preservative To Prepare Calibrators, You Must Add Distilled Water. Storage And Stability Store At 2‑8 °C. Lyophilized Calibrators Are Stable Until The Stated Expiration Date. Stability Of Refurbished Calibrators: At -20 °C ± 5 °C 90 Days, At 2‑8 °C 120 Hours, On Board The Cobas E 411 Analyzer At 20‑25 °C Up To 5 Hours. Shelf Life: At Least 60% Of The Stated Expiration Date On The Package. Suitable For Use On The Cobas Pro Analyzer, Control For Rheumatic Factor Rfii, 4*1 Ml (2 Levels) For Cobas Pro Analyzer, Precicontrol Anti-Hcv Control For Cobas Pro Analyzer, Precicontrol Antisarscov2 Control For Cobas Pro Analyzer, Anti-Tg Calset Calibrator For Cobas Pro Analyzer, Anti-Tpo Calset Calibrator For Cobas Pro Analyzer, Afp Calset Calibrator For Cobas Pro Analyzer, Activator For Cobas C For Cobas Pro Analyzer, Precicontrol Anti-Ccp Control For Cobas Pro Analyzer, Acth Calset Calibrator For Cobas Pro Analyzer, Precicontrol Hba1c Norm Control For Cobas Pro Analyzer, Precicontrol Hba1c Path Control For Cobas Pro Analyzer, Free Psa Cs Elecsys V3 Calibrator For Cobas Pro Analyzer, Folate Calset Calibrator For Cobas Pro Analyzer, Fsh Cs Elecsys V3 Calibrator For Cobas Pro Analyzer, Precicontrol He4 Control For Cobas Pro Analyzer, He4 Calset Calibrator For Cobas Pro Analyzer, Hgh Calset Calibrator For Cobas Pro Analyzer, Homocysteine Calibrator Kit For Cobas Pro Analyzer, C-Peptide Calset Calibrator For Cobas Pro Analyzer, Ft3 Iii Calset Calibrator For Cobas Pro Analyzer, Ft4 Calset Calibrator For Cobas Pro Analyzer, Hcg+Beta Calset Calibrator For Cobas Pro Analyzer, Dheas Calset Calibrator For Cobas Pro Analyzer, Cyfra 21-1 Calset Calibrator For Cobas Pro Analyzer, Universal Diluent Diluent Multiassay For Cobas Pro Analyzer, Diluent Universal E2g For Cobas Pro Analyzer, C.F.A.S Hba1c Calibrator For Cobas Pro Analyzer, Estradiol Calset Calibrator For Cobas Pro Analyzer For 300 Determinations, Ferritin Calset Calibrator For Cobas Pro Analyzer For 300 Determinations, Calcitonin Calset Calibrator For Cobas Pro Analyzer, Cea Calset Calibrator For Cobas Pro Analyzer, Universal Calibrator C.F.A.S. For Cobas Pro Analyzer, Lpa Calset Calibrator For Cobas Pro Analyzer, Precicontrol Lpa 2 Control For Cobas Pro Analyzer, Tray For Cuvettes And Assaytip/Assaycup Tray For Cobas Pro Analyzer, Calibrator Ca 125 Calset For Cobas Pro Analyzer, Cortisol Calset Calibrator For Cobas Pro Analyzer, Calibrator Ca 15-3 Calset For Cobas Pro Analyzer, Calibrator Ca 19-9 Calset For Cobas Pro Analyzer, C.F.A.S Ck-Mb Calibrator For Cobas Pro Analyzer
Key Value
Tender Value
77,072,214 - KZT
Tender Documents
Global Tender Document
e7c36fb5-2acb-4a00-82ce-6a17fe76a6b4.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.