GTR 107984502
Tenders Are Invited For Medical Products
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
107984502
Tendering Authority
Subscribe to view
Tender No
16025593
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Medical Products
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
04-02-2026
Closed
Work Detail
Balloon Catheter For Transluminal Angioplasty Of High-Pressure Coronary Arteries. Cylinder Material And Cylinder Structure: Three-Layer - Elastomer/Nylon/Elastomer. Balloon Diameter (Mm): 2.00; 2.25; 2.5; 2.75; 3.0; 3.25; 3.5; 3.75; 4.0; 4.5; 5.0. Length: 6, 8, 12, 15, 20, 25, 30 Mm. Hydrophilic M-Coating For Distal 32 Cm. Lack Of Hydrophilic Coating On Cylinders 6 And 8 Mm Long. 2 X-Ray Contrast Markers. Distal Balloon Profile 0.036. Distal Tip With Profile 0.42Mm And Length 2.9Mm. Quick Change Balloon For Guidewire 0.014. The Working Length Of The Catheter Is At Least 145 Cm. The Diameter Of The Proximal Shaft Is 1.9 Fr, The Distal Shaft Is 2.6 Fr. Nominal Pressure 12 Atm. Burst Pressure 22 Atm (For Cylinders With A Diameter Of 2.00-4.00) And 20 Atm. (For Cylinders With A Diameter Of 4.50-5.00). The Balloon Design Is Three-Leaf With Short Arms Of 3 Mm. Thin And Short Radiopaque Marks 0.8 Mm Long And 25 Microns Thick. A Short Stainless Steel Stylet In The Middle Shaft To Strengthen The Exit Port For The Guide And Prevent Kinks, To Ensure The Transfer Of Pushing Force From The Proximal To The Distal Segment Of The Catheter., The Microcatheter Is Equipped With A System That Allows The Distal Tip Of The Catheter To Come Off If It Sticks To The Embolisate When A Certain Tension Value Of The Microcatheter Is Reached. Minimal Impact On Arteries. Minimal Risk Of Bleeding. The Microweave Type, Combined With Progressively Decreasing Stiffness And Diameter, Strengthens The Flexible Distal Part Of The Microcatheter And Makes It Resistant To High Pressure. This Ensures Safety During Injections. The Flow-Controlled Microcatheter Has Good Flexibility, Providing Excellent Navigation Properties. Full Dmso Compatibility. Supplied With A Hydrophilic Hybrid Microconductor Included. The Length Of The Tear-Off Tip Is 1.5 - 2.5 Cm, The Total Length Is 165 - 190 Cm. Tip Diameters: Outer - 1.2 - 1.5 F, Inner - 0.17-0.27 Mm. Maximum Reflux 2-3 Cm., Intravascular Guidewire: Diameter - 0.035 Inches, 0.038 Inches. Length – 75 Cm, 145 Cm, 180 Cm, 260 Cm. Core Material – Stainless Steel. Core Design – Enhanced Support. Coating – Teflon (Ptfe). Tip Shape – Straight, J 3 Mm, Distal Segment Being Formed 3 Cm. Flexible Tip Length – 1 Cm, 4 Cm, 6 Cm, 7 Cm. Dimensions Are Provided According To The Doctor’S Request., Calcium Electrode For Use On The Avl 9180 Electrolyte Analyzer, Printer Paper 5 Rolls For Use On The Avl 9180 Electrolyte Analyzer, Cleaning Solution For Use On The Avl 9180 Electrolyte Analyzer, 125 Ml, Control Material For Use On The Avl 9180 Electrolyte Analyzer, Catheter For Thrombus Aspiration. Must Have An Elastic Distal Tip, At Least 16 Transition Zones, Double Nitinol Braid Along The Entire Length To Ensure The Lumen Remains Unchanged, And A Polymer Coating. The Presence Of One X-Ray Marker At The Distal End. Force Transmission 1: 1. Shape Type – Conical. Must Be Compatible With 0.014 Guidewire. Must Be Compatible With 0.088 Bore Guide Catheter. Must Be Compatible With A Microdelivery Catheter With An Outer Diameter Of 3.8F To 4.7F. The Catheter Must Be Hydrophilic. The Outer Proximal Diameter Is 6F, The Internal Lumen Is Not Less Than 0.068. Working Length Is Not Less Than 132 Cm. The Catheter Is Equipped With A Steam Forming Mandrel And A Rotating Hemostatic Valve. The Kit Includes A Connecting Tube With A Length Of At Least 285 Cm. The Plastic Tube Is Reinforced With Steel Braid, With A Switch, Transparent. The Presence Of A Leuer-Type Adapter, A Flow Switch. Extended Flexible Distal Tip To Ensure Maximum Patency In Convoluted Anatomy Maintaining A Constant Internal Lumen During The Aspiration Procedure., Reference Electrode For Use On The Avl 9180 Electrolyte Analyzer, Reference Electrode Holder For Use On The Avl 9180 Electrolyte Analyzer, Non-Adhesive Radiopaque Dmso-Soluble Implant For Embolization Of Pathological Changes Of Various Locations, Complete With Syringes. Density Index – 18, 20, 34, 34L. The System Includes An Ampoule With 1.5 Ml Of Embolic Agent, An Ampoule With 1.5 Ml Of Dmso Solvent, 3 Syringes With A Volume Of 1 Ml., Potassium Electrode For Use On The Avl 9180 Electrolyte Analyzer., Guide Catheter For Peripheral Vessels, Sodium Electrode Conditioner For Use On The Avl 9180 Electrolyte Analyzer, 125 Ml, Non-Adhesive Radiopaque Dmso-Soluble Implant For Embolization Of Pathological Changes Of Various Locations, Complete With Syringes. Density Index – 34. The System Includes An Ampoule With 6.0 Ml Of Embolic Agent, An Ampoule With 1.5 Ml Of Dmso Solvent, 8 Syringes With A Volume Of 1 Ml., Set With A Two-Channel High-Flow Catheter For Seldinger Placement. Designed For Emergency Dialysis And High-Speed Infusion: Flow Rate Through Channel 1 - 234 Ml/Min, Through Channel 2 - 261 Ml/Min. Art. 4167546 V 1220 Needle Type V: 18G; Length 70 Mm Conductor (Flexible) 0.89 Mm X 50 Cm Catheter: 12F - D 4.0 Mm; Length 20 Cm Channels 11G / 11G Certon Polyurethane Catheter With Soft Tip O Opaque, Rg-Contrast, With Marking Along The Length And Fixing Wings O Color Coding Of Connectors O Needle-Free Connectors Safesite Movable Adjustable Wings For Fixing The Catheter • Guidewire With Flexible J-Tip; Bend-Resistant Guidewire (Included In All Sets With A V-Cannula) • 5 Ml Syringe With A Threaded Connection (Included In All V-Sets) • Dilator, Scalpel, Connecting Ecg Cable • Mobile Fixing Clamp (For All Catheters Over 15 Cm In Length) Guide Cannulas: S - Seldinger Needle V - Needle With An Additional Port B - Braunula. The Remaining Shelf Life Upon Delivery Is At Least 60% Of The Shelf Life Indicated On The Packaging., Guiding Catheters. Purpose For Carrying Out Interventional Instruments. Shape And Length: Possibility Of Choosing Special Shapes For Access Through The Radial (Tiger) And Femoral Arteries (Extra Backup) With A Length Of 100 Cm, And 125 Cm For Catheters With The Multipurpose Shape., Sodium Electrode For Use On The Avl 9180 Electrolyte Analyzer, Hybrid Guiding Catheter For Transfemoral And Transradial Intervention, Balloon Catheters For Transluminal Angioplasty Of The Coronary Arteries. Diameter (Mm): 1.0; 1.25; 1.5 - 1 Radiopaque Mark; 2.0; 2.25; 2.5; 2.75; 3.0; 3.25; 3.5; 3.75; 4.0 - 2 Radiopaque Marks. Length 5; 10; 20; 40 Mm Balloon Material Nylon 12. M-Coat Balloon Catheter With Red Flexible Tip For Better Visibility. Stainless Steel Guide Core For Optimal Pushability. 0.41 Mm Balloon Entry Profile. 1.5 Mm And 0.43 Mm For Balloon Catheters With A Diameter Of 2.0 To 4.0 Mm. Working Profile Of The Balloon Is 0.58 Mm For Balloon Catheters With A Diameter Of 1.0 Mm, 0.62 Mm For Balloon Catheters With A Diameter Of 1.25 Mm, And 0.73 Mm For Balloon Catheters With A Diameter Of 2.0 To 4.0 Mm. 145 Cm. Nominal Pressure 6 Atm. Burst Pressure 14 Atm., For Balloon Catheters With A Diameter Of 1.0-3.0 Mm, And 12 Atm., For Boats With A Diameter Of 3.25-4.0 Mm. Material Of Radiopaque Balloon Mark: Platinum - Iridium. Thin And Short Recessed Radiopaque Markers 0.8 Mm Long And 25 Mm Thick. Μm. The Presence Of Depth Markers At A Distance Of 90 Cm And 100 Cm From The Distal Tip Of The Catheter. The Diameter Of The Proximal Shaft Is 1.9 Fr (0.64 Mm), The Diameter Of The Middle Shaft Is 2.5 Fr (0.84 Mm), The Diameter Of The Distal Shaft Is 2.4 Fr (0.79 Mm) – 2.7 Fr (0.89 Mm) For Balloon Catheters Diameter From 1.0 To 1.5 Mm And 2.6 Fr (0.87 Mm) For Balloon Catheters With Diameter From 2.0 To 4.0 Mm. Compatible With 4Fr (0.050 Inch / 1.27 Mm) Guide Catheter. Balloon Design Is Three-Lobe For Balloon Catheters In Diameter. 2.25 To 4.0 Mm, Two-Leaf For Balloon Catheters With A Diameter Of 1.0 To 2.0 Mm.
Key Value
Tender Value
35,499,239 - KZT
Tender Documents
Global Tender Document
3837ce20-a293-4f61-8967-d1c467ae355d.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.