GTR 107055824

Bids Are Invited For Stationary Emergency Diesel Generator Set, Intended For Installation In A Reserved Location According To The Project, And Must Enter Into Automatic Operation After Failure Of The Power Supply Network Or According To A Pre-Defined Time Schedule. The Equipment Must Have Locks That Prevent Operation In Parallel With The Network, An Acoustic Cabin For Installation At The Same Time With A Maximum Noise Level Of 75 Db(A) At 7 Meters, Power In Continuous Operation (Prime) Of 192 Kva And In Emergency (Stand-By) Of 211 Kva, Nominal Three-Phase Voltage Of 220/127 V, Reconnectable At 220/380/440 V, Frequency Of 60 Hz, Power Factor 0.8 And Speed Of 1800 Rpm. The Engine Must Be Diesel, Water-Cooled By Radiator, Have At Least 5 Cylinders In Line, Mechanical Speed Governor, Preheating System And 12 Vdc Electric Starter With Lead-Acid Batteries And Automatic Charger. The Alternator Must Be Three-Phase, Brushless, Self-Exciting... Continue Reading >

ICB — International Competitive Bid Closed South America
Tender Information
GTR Reference
107055824
Tendering Authority
Subscribe to view
Tender No
88/2025
Financer Name
Self-Funded
Work Title
Bids Are Invited For Stationary Emergency Diesel Generator Set, Intended For Installation In A Reserved Location According To The Project, And Must Enter Into Automatic Operation After Failure Of The Power Supply Network Or According To A Pre-Defined Time Schedule. The Equipment Must Have Locks That Prevent Operation In Parallel With The Network, An Acoustic Cabin For Installation At The Same Time With A Maximum Noise Level Of 75 Db(A) At 7 Meters, Power In Continuous Operation (Prime) Of 192 Kva And In Emergency (Stand-By) Of 211 Kva, Nominal Three-Phase Voltage Of 220/127 V, Reconnectable At 220/380/440 V, Frequency Of 60 Hz, Power Factor 0.8 And Speed Of 1800 Rpm. The Engine Must Be Diesel, Water-Cooled By Radiator, Have At Least 5 Cylinders In Line, Mechanical Speed Governor, Preheating System And 12 Vdc Electric Starter With Lead-Acid Batteries And Automatic Charger. The Alternator Must Be Three-Phase, Brushless, Self-Exciting... Continue Reading >
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
15-01-2026 Closed
Work Detail
Stationary Diesel Emergency Generator Group, Intended For Installation In A Reserved Location According To The Project, And Must Enter Into Automatic Operation After Failure Of The Electrical Supply Network Or Through A Pre-Defined Time Schedule. The Equipment Must Have Locks That Prevent It From Operating In Parallel With The Network, An Acoustic Cabin For Installation At The Same Time With A Maximum Noise Level Of 75 Db(A) At 7 Meters, Power In Continuous Operating Mode (Prime) Of 192 Kva And In Emergency Mode (Stand-By) Of 211 Kva, Nominal Three-Phase Voltage Of 220/127 V, Reconnectable To 220/380/440 V, Frequency Of 60 Hz, Power Factor 0.8 And Rotation Of 1800 Rpm. The Engine Must Be Diesel, Refrigerated
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
e059a2f5-4a0c-4be0-8655-4837416ecf04.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders