GTR 106886765

Bids Are Invited For Hiring A Specialized Company For The Acquisition Of A Cardiover Monitor/Defibrillator To Meet The Needs Of The Municipal Health Network Of The Municipality Of Olho D´Água Do Borges/Rn

ICB — International Competitive Bid Closed South America
Tender Information
GTR Reference
106886765
Tendering Authority
Subscribe to view
Tender No
1024001/2025
Financer Name
Self-Funded
Work Title
Bids Are Invited For Hiring A Specialized Company For The Acquisition Of A Cardiover Monitor/Defibrillator To Meet The Needs Of The Municipal Health Network Of The Municipality Of Olho D´Água Do Borges/Rn
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
05-01-2026 Closed
Work Detail
Cardioverter (Pacemaker / Aed / Ecg) Basic Specification: For Defibrillation, Cardioversion Equipment Equipped With Aed Mode And Resources For Ecg Monitoring. Basic Application: Cardiac Defibrillation And Cardioversion, External Pacemaker And Ecg Monitoring In Adult And Pediatric Patients. Description:• Command On The Paddles: Must Allow Charging And Triggering Directly On The Paddles For Greater Agility In Use.• Ecg Memory: Must Have A Storage System01 For Review And Later Analysis Of Recorded Events.• Pacemaker: Equipment Must Have External Pacemaker Function For Temporary Cardiac Stimulation. • Have Aed Module (Automatic External Defibrillator). •Charge And Trigger Command Directly On The Paddles.• Memory For Storing Ecg Records.• Integrated Printer.• Operating Modes: Manual, Synchronized And Dea.• Adjustable Energy Range Between 1 J And 360 J.• Ecg Monitoring In Real Time With High Visibility Screen.• Protection Against Electrical Overloads And External Defibrillation.• Powered By Rechargeable Battery With Minimum Autonomy Of 3 Hours Monitoring Or 100 Shocks At 360 J.• Capture Of The Ecg Signal By The Permanent Paddles, By The Adhesive Paddles And By The Patient Cable• Indication Of The Contact Of The Paddles On The Patients Chest• Analysis Of The Patients Thoracic Impedance And Detection Of Pacemaker Pulse• Visual And Audible Alarm System• Minimum Screen 7
Key Value
Tender Value
31,340 - BRL
Tender Documents
Global Tender Document
9a453239-cbed-4829-91cf-689a9543b47f.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders