Complete Cleaning Services For Window And Split Air Conditioning Equipment (Evaporator And Condenser). The Heat Exchanger (Coil), Axial Fan, Fairing, Drain Gutter And All Components Must Be Cleaned. It Is Necessary To Remove The Equipment From Its Location And Complete Installation Of The Window And Split Air Conditioning Equipment. The Service Must Include Relocation Of The Device (Even To Another Address), If Necessary. For Equipment Up To 12,000 Btus, If Necessary. For 18,000 Btus Equipment, 12/09/2025 - 00:10:55, 12/09/2025 - 00:10:57, 12/09/2025 - 00:10:58, If Necessary. For 24,000 Btus Equipment, If Necessary. For Equipment Above 30,000 Btus, Complete Uninstallation Of Window And Split Air Conditioning Equipment. The Service Must Include Relocation Of The Device (Even To Another Address), If Necessary. For Equipment Up To 18,000 Btus, Service Provision - Labor Corrective Maintenance Of Air Conditioners - By Call. Observations: Includes Displacement And Initial Diagnosis., Refrigerant Gas For Air Conditioning - Kg, Capacitors In General. Capacitors 15Mf To 45Mf + Or - 5%, 450-Vac- Pin- 50/60Hz: Operating Class Class B (10000 H) Class C (3000 H); Safety Protection Class P2/P1; Voltage Range 200 ~ 500Vac; Capacitance Range 2 ~ 120Mf; Capacitance Tolerance ±5%; Dissipation Factor 20 × 10-4 (100Hz, Fan Motor 7,000 To 18,000Btus, Nominal Power: 30W To 45W - Operating Voltage: 208~ 220V - Mains Frequency: 60Hz - Operating Voltage: 0.35A To 0.4A, Rotation: 850 Rpm Anti Hours, Protection Class: Ip65., Fan Motor 24,000 To 30,000Btus - Nominal Power: 45W To 74W - Operating Voltage: 208~ 220V - Mains Frequency: 60Hz - Operating Voltage: 0.4A To 0.48A, Compressor Ae 240 Air Com. Up To 9000Btus Rotary Capacity: 5/8 A 1 Ph Lra22.0 -Voltage 208~220V - Frequency: 60Hz -Gas Type: R22 Suction Line Connection: 3/8¨ Discharge Line Connection: 1/4¨, Compressor Ae 240 Air Com. 12000 Btus, Compressor Ae 240 Air Com. 18000 Btus, Compressor Ae 240 Air Com. 24,000 To 30,000Btus Rotary Capacity: 1 Ph Lra68.0 To Ph 401X3cs-3Muu -Voltage 208~220V -Frequency: 60Hz -Gas Type: R22 Suction Line Connection: 5/8¨ Discharge Line Connection: 3/8¨, Service Valves 1/4¨, 3/8¨, 1/2¨, 5/8¨With Registration. Type: Schrader Inensys With Fringed Brass Cover Seal., Support 7 To 30K Btu/H Measurement: 400 To 500 Millimeters, Type: L Material: Carbon Steel Static Painting Capacity: 80Kg A 100Kg, Universal Evaporator Board Model: U02b Version: V3.0 Capacity: 7000 Btus Input Voltage: 220V Output Voltage: 12V Frequency: 60Hz., Hi Wall Split Air Evaporator Main Board 9,000Btus Model: 42Mcc007515ls Input Voltage: 220V Output Voltage: 12V Frequency: 60Hz., Main Electronic Board 9 To 24,000 Btus Mods. 7/24., Split Ambient Temperature Sensor 5K 7/24