Bids Are Invited For Price Registration For Future And Possible Acquisition Of Simulators And Analyzers For Medical Equipment To Meet The Needs Of Health Care Establishments (Eas), With Aim To Meet The Needs Of Bodies And Entities In The State Of Sergipe.

Tender Detail

105048133
PE0440/2025
Self-Funded
Bids Are Invited For Price Registration For Future And Possible Acquisition Of Simulators And Analyzers For Medical Equipment To Meet The Needs Of Health Care Establishments (Eas), With Aim To Meet The Needs Of Bodies And Entities In The State Of Sergipe.
NCB
South America
BRIC,G20
04-12-2025

Work Detail

Analyzer - Scalpel For Testing, Displays Envelope Curve And Power Test Crest Factor, Liquid Crystal Screen (Lcd) Or Digital Display, Power Of Up To 400W, With Resolution Of 0.1W, Battery With Autonomy Of At Least 05 Hours, With Calibration Certificate, With Training Included, With All Accessories For The Full Operation, With Bag To Store The Equipment. 12 Month Warranty, Analyzer - Defibrillator Analyzer - Used For Tests On Cardioverters, Defibrillators, Aeds, Simulation Of 12, Conductors; Ra, Ll, La, Rl, V1-6, Ecg, Arrhythmia, Sinusoidal, Triangular And Square Signal Simulator Operates In Manual Mode Or Connected To The Computer, Reading Is On A Touch Screen Where The Data Must Be Displayed, With Independent Outputs, Energy In Joules (J), With Internal Lithium-Ion Battery, Has An Internal Load Of 50Ω With Software For Issuing The Certificates And Reports, 220V, Must Come With All Accessories For Full Functioning And Have A Backpack For Storage. 12-Month Warranty, Analyzer - Mechanical Ventilation, Flow, Pressure, Temperature, Humidity, Oxygen, Frequency:-/+ 300 Slpm; -/+ 160 Mbar, 0 To 50°C; 0 To 100%; - Controlstand Alone And Computer, Volume - 100 A + 100 Liters And Error ±2%, - Degass Flow -300 To +300 L/Min, Resolution 1Ml/Min, Error ±3%. - Gas Flow -300 To +300 L/Min, Resolution 1 Ml/Min, Error ±3%. Oxygen Concentration 0~100%, Resolution 0.5%, Error ±2%. - High Pressure -0.8 To 10 Bar, Error ±1%. Pressure -160 To +160 Mbar, Error ±1%, Barometric Pressure 600 To 1200 Mbar, Error±1%. - Temperature 0 To 50°C, Error 0.2°C. - Humidity 0 To 100%, Error ±5%. O20 At 100%, Error ±2% -Worked Parameters: Inspiratory Tidal Volume 0A 60 L, Error 2%. Expiratory Tidal Volume 0 To 60 L, Error 2%. Minute Volume With Measurement Range From, At Minimum, 0 To 100 L, Error 2%. Respiratory Rate 1 To 1500 Rpm, Error 1%., Electrical Safety Analyzer - Performs All Leakage Current Tests Of Both Standards, Checks Grounding Resistance, Performs Insulation Test Between Two Points Of The Equipment (500V), Automatic Standard Tests, 5? Or Digital Display, With Lithium Ion Battery, Comes With All Accessories For Operation, Including Adapters, Cables, Sensors, Charger And Calibration Certificate Traceable To Rbc, 12 Month Warranty, Multi-Parameter Simulator - For Testing Multiparameter Monitors, Simulates Non-Invasive Pressure, Invasive Pressure, Breathing, Ecg, Test Signals And Arrhythmias, Analyzes Static Pressures And Leaks Of Pneumatic Systems And Oximetry Simulation, Powered By Lithium Ion Battery, Comes With Charger, Manual In Portuguese And, Calibration Certificate Traceable To Rbc, Usb Communication, With Backpack For Equipment, 12-Month Warranty, 19/11/2025 - 11:41:54, 11/19/2025 - 11:41:56, 11/19/2025 - 11:42:05

Key Value

Tender Value
Refer document

Attachment

FileName File Description
Global Tender Document 3732d8af-7ef6-40cc-adbb-b60628dea7f1.html
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail