Analyzer - Scalpel For Testing, Displays Envelope Curve And Power Test Crest Factor, Liquid Crystal Screen (Lcd) Or Digital Display, Power Of Up To 400W, With Resolution Of 0.1W, Battery With Autonomy Of At Least 05 Hours, With Calibration Certificate, With Training Included, With All Accessories For The Full Operation, With Bag To Store The Equipment. 12 Month Warranty, Analyzer - Defibrillator Analyzer - Used For Tests On Cardioverters, Defibrillators, Aeds, Simulation Of 12, Conductors; Ra, Ll, La, Rl, V1-6, Ecg, Arrhythmia, Sinusoidal, Triangular And Square Signal Simulator Operates In Manual Mode Or Connected To The Computer, Reading Is On A Touch Screen Where The Data Must Be Displayed, With Independent Outputs, Energy In Joules (J), With Internal Lithium-Ion Battery, Has An Internal Load Of 50Ω With Software For Issuing The Certificates And Reports, 220V, Must Come With All Accessories For Full Functioning And Have A Backpack For Storage. 12-Month Warranty, Analyzer - Mechanical Ventilation, Flow, Pressure, Temperature, Humidity, Oxygen, Frequency:-/+ 300 Slpm; -/+ 160 Mbar, 0 To 50°C; 0 To 100%; - Controlstand Alone And Computer, Volume - 100 A + 100 Liters And Error ±2%, - Degass Flow -300 To +300 L/Min, Resolution 1Ml/Min, Error ±3%. - Gas Flow -300 To +300 L/Min, Resolution 1 Ml/Min, Error ±3%. Oxygen Concentration 0~100%, Resolution 0.5%, Error ±2%. - High Pressure -0.8 To 10 Bar, Error ±1%. Pressure -160 To +160 Mbar, Error ±1%, Barometric Pressure 600 To 1200 Mbar, Error±1%. - Temperature 0 To 50°C, Error 0.2°C. - Humidity 0 To 100%, Error ±5%. O20 At 100%, Error ±2% -Worked Parameters: Inspiratory Tidal Volume 0A 60 L, Error 2%. Expiratory Tidal Volume 0 To 60 L, Error 2%. Minute Volume With Measurement Range From, At Minimum, 0 To 100 L, Error 2%. Respiratory Rate 1 To 1500 Rpm, Error 1%., Electrical Safety Analyzer - Performs All Leakage Current Tests Of Both Standards, Checks Grounding Resistance, Performs Insulation Test Between Two Points Of The Equipment (500V), Automatic Standard Tests, 5? Or Digital Display, With Lithium Ion Battery, Comes With All Accessories For Operation, Including Adapters, Cables, Sensors, Charger And Calibration Certificate Traceable To Rbc, 12 Month Warranty, Multi-Parameter Simulator - For Testing Multiparameter Monitors, Simulates Non-Invasive Pressure, Invasive Pressure, Breathing, Ecg, Test Signals And Arrhythmias, Analyzes Static Pressures And Leaks Of Pneumatic Systems And Oximetry Simulation, Powered By Lithium Ion Battery, Comes With Charger, Manual In Portuguese And, Calibration Certificate Traceable To Rbc, Usb Communication, With Backpack For Equipment, 12-Month Warranty, 19/11/2025 - 11:41:54, 11/19/2025 - 11:41:56, 11/19/2025 - 11:42:05