GTR 104443353

Bids Are Invited For Acquisition Of Lancets, Reagent Strips And The Like

ICB — International Competitive Bid Closed South America
Tender Information
GTR Reference
104443353
Tendering Authority
Subscribe to view
Tender No
000016/2025
Financer Name
Self-Funded
Work Title
Bids Are Invited For Acquisition Of Lancets, Reagent Strips And The Like
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
21-11-2025 Closed
Work Detail
Disposable Sterile Lancet Sterile, Disposable Lancet That Meets The Requirements Of Nr32 Single-Use Puncture System With 1 Depth Adjustment; With External Activator, Depth Of Between 1.4Mm To 1.8Mm Needle Diameter: 0.36 Mm (28 G); Three-Faced And Silicone Lancet. Sterile System Using Gamma Radiation. Automatic Needle Retraction. Meet Regulatory Standards And Good Manufacturing Practices Certificate Issued By Anvisa. Packed In A Box With 100 Units., Reagent Strip For Measuring Blood Glucose Mg/Dl, Accepting Lower And Higher Values Than These. Reading Methodology By Photometry Or Amperometry, With Dehydrogenase Enzymatic Chemistry, Thus Not Interfering With Oxygen And Cases Of Patients Undergoing Oxygen Therapy. Hematocrit Range From 20 To 70% (Accepting 5% Above Or Below The Range). Sample Size Up To 2 Microliters. Does Not Present Interference With Analgesics, Antipyretics, Vasoactive Drugs And Antihypertensives. Monitor With Automatic Coding Without The Need For A Chip, Code Strip Or Other Types Of Manual Comparison Procedures, To Facilitate Use And Avoid Errors. It Should Be Possible To Apply A Complementary Drop Of Blood To The Same Strip When The Sample Is Insufficient To Avoid Waste (At Least 20 Seconds). Reliable Results When Compared With Laboratory Reference Methods. Packaging In A Bottle With 50 Strips Made Of Material That Guarantees The Integrity Of The Product And Must Be Accompanied By Leaflets/Instructions For Use. The Labeling Must Contain The Batch Number, The Validity Of The Strips Must Be Maintained After Opening The Bottle As Described On The Original Packaging. The Reading Equipment Must Not Interfere With Common Electromagnetic Blood Glucose Devices (Cell Phones, Computers, Remote Controls, Etc.). Additional Features: Compatible Battery Supply Guarantee. Whenever There Are Operating Problems, The Devices Must Be Replaced. In-Person Training And Training By A Healthcare Professional Responsible For Using The Equipment. Iso 15197/2013. Registration With Anvisa; Brand A, Device For Measuring Blood Glucose Capillary Blood Glucose Device New Device; Autocoded; Photometric Biosensor Technology (Reflectance); Measuring Range: 10 To 600 Mg/Dl; Allows Sample Collection With The Test Strip Outside The Monitor; Detection Of Insufficient Blood Sample; Results In 5 Seconds (Collection With The Strip Inside The Monitor) And 8 Seconds (Collection With The Strip Outside The Monitor); Automatically Turns On When The Test Strip Is Placed And Turns Off When Removed; Memory For 500 Results With Date And Time. Average Of 7, 14, 30 And 90 Days; Permanent Warranty For The Monitor, According To The Product Manual; Containing Instruction Manual, 1 Cr 2032 Battery And Monitor Storage Case. Note: Brand Accu Chek Active, Compatible With The Strips, 07/11/2025 - 15:33:20
Key Value
Tender Value
69,700 - BRL
Tender Documents
Global Tender Document
0e6376a3-2bb2-4a6d-ab9d-2b10e5feff36.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders