Bids Are Invited For Price Registration For The Acquisition Of A Hematological Analyzer Device To Service The Municipal Hospital Of Minaçu-Go.

Tender Detail

103909799
046/2025
Self-Funded
Bids Are Invited For Price Registration For The Acquisition Of A Hematological Analyzer Device To Service The Municipal Hospital Of Minaçu-Go.
NCB
South America
BRIC,G20
12-11-2025

Work Detail

Hematology Analyzer 5 Parts. 36 Parameters, Or More, The Following Being Mandatory: Spectrophometric Reading Of Hemoglobin (Cyanomethemoglobin) Without Using Cyanide In The Reagent; Total Erythrocyte Count; Total Leukocyte Count; Determination Of Average Corpuscular Volume And Cell Size; Determination Of Mean Corpuscular Hemoglobin; Average Corpuscular Hemoglobin Concentration Determination Hematocrit; Total Platelet Count; Total Platelet Count; Determination Of The Anisocytosis Index; Determination Of Average Platelet Volume; Determination Of Platelet Distribution Amplitude In Standard Deviation; Absolute Value Count For Lymphocytes; Lymphocyte Percentage (Relative Value); Rate Of Large Cells And Platelets; Coefficient Of Variation Amplitude Distribution Red Blood Cells; Large Cell Count; Total Neutrophil Count; Neutrophil Percentage; Total Eosinophil Count; Percentage Of Eosinophils; Total Monocyte Count; Monocyte Percentage; Total Basophil Count; Percentage Of Basophils; Neutrophil-Lymphocyte Ratio; Platelet-To-Lymphocyte Ratio; Percentage (Relative Value) Of Atypical/Abnormal Lymphocytes; Count (Absolute Value) Of Atypical/Abnormal Lymphocytes; Percentage (Relative Value) Of Large Immature Cells; Count (Absolute Value) Of Large Immature Cells; In Addition To The Above Parameters, You Must Perform 2 Histograms, And 2 Scattergrams, Or More; Speed: 70 Samples/Hour, Or Higher; Sample Volume: Carry Out Tests Starting From 20?L Of Sample, Or With An Even Smaller Volume. Operating System: Cyanide-Free Colorimetry (Hgb), 3 Laser Dispersion Angles By Flow Cytometry And Electrical Impedance, Containing Dual Channel And Real Optical Method With Dedicated Channel For Diff And Basophils; Homogenization Of Samples And Reagents Without Shear-Valve; Cytochemistry, Impedance And Laser Optics For Diff Counting. Of Leukocyte Populations. System Using A Maximum Of 3 Reagents. Printed, 10/28/2025 - 14:25:02, 10/28/2025 - 14:25:31

Key Value

Tender Value
76,183 - BRL

Attachment

FileName File Description
Global Tender Document 6ee46135-8edd-44c4-a964-130502e8ebd0.html
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail