Bids Are Invited For Monthly Lease Of 02 (Two) 3Kva Nobreaks With Double Conversion Technology, Accompanied By 02 (Two) Banks Of External Batteries With A Minimum Autonomy Of 60 (Sixty) Minutes At Full Charge, One Set Intended For The Data Processing Center (Cpd) From The Headquarters Of The Municipal Government Of Caxambu/Mg And The Other To The Innovation Center, Located On The Premises Of The Military Police Battalion Of Caxambu/Mg, According To The Terms Of Reference And Preliminary Technical Study, Integral Parts Of This Notice
Bids Are Invited For Monthly Lease Of 02 (Two) 3Kva Nobreaks With Double Conversion Technology, Accompanied By 02 (Two) Banks Of External Batteries With A Minimum Autonomy Of 60 (Sixty) Minutes At Full Charge, One Set Intended For The Data Processing Center (Cpd) From The Headquarters Of The Municipal Government Of Caxambu/Mg And The Other To The Innovation Center, Located On The Premises Of The Military Police Battalion Of Caxambu/Mg, According To The Terms Of Reference And Preliminary Technical Study, Integral Parts Of This Notice
Contracting Services 02 Online Ups (Ups) – 3 Kva Each Unit Must Meet The Following Minimum Characteristics:Nominal Power: 3 Kva (2700 W) With Dsp Technology (Digital Signal Processor);Topology: Double Online Conversion (Vfi);•Power Factor: = 0.98;Tower Model;Input Voltage: 208V / 220V / 230V / 240V Ac;Output Voltage: 208V / 220V / 230V / 240V Ac Adjustable Via Lcd;Transfer Time: 0 Ms (Mains – Battery);Output Frequency: 50/60 Hz ± 0.2 Hz (In Battery Mode);Overload Capacity: Up To 150% With Transfer To Bypass According To Specification;•Waveform: Pure Sine;Efficiency Minimum:Ac Grid Mode: = 90%Battery Mode: =87%Eco Mode: = 98%Communication: Snmp (Mandatory), Rs232, Rj45 And Usb;Automatic Ventilation Control;•Automatic Recharge Function Even When Turned Off;Maximum Noise: = 50 Db At 1 M;Protections: Undervoltage, Overvoltage, Surges, Overload And Short Circuit; The Equipment Made Available On Lease Must Be New, Without Previous Use, Accompanied By An Invoice And A Declaration From The Bidder Certifying The Originality And Direct Origin Of The Manufacturer Or Authorized Distributor; External Each Bank Must Meet The Following Minimum Characteristics: Technology: Vrla Agm (Valve Regulated Lead Acid, Absorbent Glass Mat), Maintenance Free;Voltage Compatible With The Ups Purchased (96 Vdc, 192 Vdc Or 240 Vdc, As Per Manufacturers Specification);Sufficient Capacity To Ensure Minimum Autonomy Of 60 Minutes At Full Load (2700 W);Maximum Recharge Time: Up To 8 Hours 90% Of Capacity; Appropriate Metal Cabinet, With Protection Circuit Breakers, Easy Access Terminals And Sized Cables; All Batteries Must Be New; Must Include: Connectors, Cables And Accessories Necessary For Safe Connection To The Ups; Supply Must Guarantee The
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.