GTR 103457733
Tenders Are Invited For Medical Consumables – Probes, Catheters, Drains, Ureteral Tubes And Other Medical Consumables
ICB — International Competitive Bid
Closed
Southern Europe
Tender Information
GTR Reference
103457733
Tendering Authority
Subscribe to view
Tender No
685361-2025
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Medical Consumables – Probes, Catheters, Drains, Ureteral Tubes And Other Medical Consumables
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Southern Europe
Last Date of Bid Submission
17-11-2025
Closed
Work Detail
Medical Consumables – Probes, Catheters, Drains, Ureteral Tubes And Other Medical Consumables. 1 Sterile Ureteral Drainage Probes Cylindrical With One Opening On The Side And Top, With Mandrel And Syringe Adapter, Graduated, Without Pvc, With Ch 5 Shape Retention, Length 69Cm,,2 Sterile Ureteral Drainage Probes Cylindrical With One Hole On The Side And Top, With Mandrel And Syringe Adapter Graduated, Without Pvc, With Ch 6 Shape Retention, Length 69Cm,,3 Sterile Ureteral Drainage Probes Cylindrical With One Hole On The Side And Top, With Mandrel And Syringe Adapter Graduated, Without Pvc, With Ch 7 Shape Retention, Length 69Cm,,4 Sterile Urethral Drainage Probes Tip Whistle - With Two Holes, With Mandrel And Syringe Adapter, Graduated, Silicone Ch 6, Length 70Cm + - 2%,,5 Sterile Urethral Drainage Probes Tip Whistle- With Two Holes, With Mandrel And Graduated Syringe Adapter, Silicone Ch 7, Length 70Cm + -2%,,6 Sterile Ureteral Drainage Probes Tip Chevassu- With Two Holes, With Mandrel And Syringe Adapter, Graduated, Silicone, Ch 7, Length 70Cm + - 2%,,7 Sterile Three-Way Prostate Catheter For Type Dufour (Latex Semi Rigide - Latex Semi-Rigid) Coated With Hydrogel With Catheter Length Of At Least 40 Cm, Balloon Volume At Least 80 Ml Ch 18,,8 Sterile Three-Way Prostate Catheter For Tip Dufour (Latex Semi Rigide - Latex Semi-Rigid) Coated With Hydrogel With Catheter Length Of At Least 40 Cm, Balloon Volume At Least 80 Ml Ch 20,,9 Sterile Three-Way Prostate Catheter Tip Dufour (Latex Semi Rigide - Latex Latex) Coated With Hydrogel With Catheter Length Of At Least 40 Cm, Balloon Volume At Least 80 Ml Ch 22,,10 Latex Balloon Catheter For Thrombectomy With Polyurethane Shaft, Single-Volume With Rigid Stylet, Sterile - Fogarty Catheter 2 Fr With Minimum Length 68.5Cm,,11 Latex Balloon Catheter For Thrombectomy With Polyurethane Shaft, Single-Volume With Rigid Stylet, Sterile - Fogarty Catheter 3 Fr With A Minimum Length Of 82.5Cm,12 Latex Balloon Catheter For Thrombectomy With Polyurethane Shaft, Single-Volume With Rigid Stylet, Sterile - Fogarty Catheter 4 Fr With A Minimum Length Of 82.5Cm,13 Latex Balloon Catheter For Thrombectomy With Polyurethane Shaft, Single-Volume With Rigid Stylet, Sterile - Fogarty Catheter 5 Fr With Minimum Length 82.5Cm,,14 Latex Balloon Catheter For Thrombectomy With Polyurethane Shaft, Single-Volume With Rigid Stylet, Sterile - Fogarty Catheter 6 Fr With A Minimum Length Of 82.5Cm, Piece, Quantity 5,15 Double ,, J ,, Probes (Sterile) Polyurethane, Made Of Soft Polished Polyurethane, For Long-Term Drainage Up To 6 Months. Diameter Ch 6 Length From Base To Base Of The Pigtail 24Cm, According To The Requirements In The Technical Specification And The Technical Offer.,16 Double ,, J ,, Probes (Sterile) Polyurethane, Made Of Soft Polished Polyurethane, For Long-Term Drainage Up To 6 Months. Diameter Ch 6 Length From Base To Base Of The Pigtail 22Cm, According To The Requirements In The Technical Specification And The Technical Offer.,Double ,, J ,, Probes (Sterile) Polyurethane, Made Of Soft Polished Polyurethane, For Long-Term Drainage Up To 6 Months. Diameter Ch 4.7 Length From Base To Base Of The Pigtail 30Cm, According To The Requirements In The Technical Specification And The Technical Offer.,18 Double J Probe - Set Of Integral Stents. The Set Consists Of A Ureteral Stent, Made Of Polyurethane, With A Retraction Wire, With Side Drainage Holes On The Pigtails And The Body And With One Open Tip...Ch 6, Length
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
32d607ac-f1f8-4039-a967-cd1d6002b054.html
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.