Quotation are invited for Tools Delivery Date: 2025/11/03 Delivery To: Electricity - Bloemhof MATERIALS STORE / PH: 444 1859 Delivery Address: 4 TALANA ROAD, Bellville Closing Date: 2025/10/29 Closing Time: 12:00 PM Description: 2 each x fluke 179 digital rms multimeter 4 each x major tech mt760 acdc 100a digital mini 3 each x kyoritsu k8112 mini clamp adaptors 2 each x major tech mtc40 tone and probe testers 7 each x sel-c662-15 usb to serial port communica Specification: * Fluke 179 True-RMS Digital Multimeter[or equivalent] Precision True-RMS AC voltage and current measuring ability as well as temperature, frequency, capacitance, resistance, continuity and diode measuring capabilities Minimum Technical Requirements: True-RMS AC voltage range:0.1 mV to 1000 V (>= 1.0% accuracy) at 0.1 mV resolution True-RMS AC current range:0.01 mA to 10 A (>= 1.5% accuracy) at 0.01 mA resolution DC voltage range:0.1 mV to 1000 V (>= 0.09% accuracy) at 0.1 mV resolution DC current range:0.01 mA to 10 A (>= 1.0% accuracy) at 0.01 mA resolution Temperature range:-40 °C to 400 °C (>= 1.0% accuracy) at 0.1 °C resolution Frequency range:2 Hz to 100 kHz (>= 0.1% accuracy) at 0.01 Hz resolution Capacitance range:1 nF to 10 000 µF (>= 1.2% accuracy) at 1 nF resolution Resistance range:0.1 ??to 50 M??(>= 0.9% accuracy) at 0.1 ? resolution) 600 V CAT IV and 1000 V CAT III overvoltage category rating Live circuit detection functionality must prevent insulation test if voltage > 30 V Backlit display with large numerical measurements Industrial rubberised housing/holster to withstand mechanical shock Compatible with TPAK magnetic hanging system Lifetime warranty Accessories to include: Test leads Temperature probe Rubberised holster (if not integrated) Contact Person: Nazarine Job 0655 988608 Delivery Address: Bloemhof Electricity Complex, Block C Bloemhof Road, Bellville * Major Tech MT760 100A ACDC Mini Digital Clamp Meter or equivalent. Compact True RMS 100A AC/DC digital clamp meter with a resolution of 1mA Minimum Technical Requirements: DC Current 2.000A - 100A ±(2.0% +3) DC Current resolution 0.01mA AC Current 2.000A- 100A ±(2.5% +8) AC current resolution 1mA DC Voltage 200.0mV # 600V ±(0.7% +3) DC Voltage resolution 0.1mV AC Voltage 2.000V # 600V ±(1.0% +3) AC Voltage resolution 1mV Resistance 200.0? # 20M? ±(1.0% +2) Resistance resolution 0.1ohm Capacitance 2.000nF # 20mF ±(4.0% +5) CAT III 300V and CAT II 600V Ø17mm Cable Clamp size 2000 count backlit LCD display VFC # Variable Frequency Drive voltage value Microprocessor Zero adjustment NCV # Non-Contact Voltage Detector Continuity buzzer and Diode Test Data Hold function Auto Power Off Required Accessories Set of Test Leads Carrying Case Contact Person: Nazarine Job 0655 988608 Delivery Address: Bloemhof Electricity Complex, Block C Bloemhof Road, Bellville * Kyoritsu K8112 Mini Clamp Adaptor or equivalen. Compact AC current/voltage conversion probe capable of measuring AC current from 0,1mA to 120A in conjunction with high sensitivity AC voltmeters for use with digital multimeters Minimum Technical Requirements: -Jaw Size: 8mm -Measuring Ranges:0.1mA to 120A AC -AC Current Resolution:0.1mA -200mA Range:Measuring Ranges:AC 0~500mA,AC 0~1000mA Output Voltage:AC1V/A ,(1000mA?1V) Accuracy:±1.5%rdg±0.2mA ,±3%rdg±0.4mA Frequency Response:50Hz~1kHz ,40Hz~10kHz 2A Range:Measuring Ranges:AC 0~20A Output Voltage: AC100mV/A , (20A?2V) Accuracy: ±1%rdg±1mA , ±1.5%rdg±2mA Frequency Response: 40Hz~1kHz , 1k~10kHz -20A Range:Measuring Ranges: AC 0~20A , AC 20~60A , AC 60~120A Output Voltage: AC10mV/A , (120A?1.2V) Accuracy: ±1%rdg±0.01A, ±2.5%rdg ,±2.5%rdg Frequency Response:40Hz~1kHz,50Hz~10kHz100Hz~10kHz -Safety Standard:IEC 61010-1 CAT II 100V -Low Battery Indication:Yes -Withstand Voltage:500V AC for 1 minute -Accessories:Carrying Case Contact Person:Nazarine Job 065 5988 608 Delivery Address: Bloemhof Electricity Complex, Block C Bloemhof Road, Bellville * Major Tech MTC40 Tone and Probe Testeror equivalent. Tone and Probe generator traces cables using a tone generator connected on one side and at the other end the probe. It is easily used to verify cable continuity, pair condition,line polarity and voltage in networking cabling systems for CAT5,coax and modular telephone lines, even when cables are in a bundle Minimum Technical Requirements: -RJ11 modular connectors -Built-in speaker on probe with sensitivity control -Traces & identifies wires/cables in a bundle or group -Insulated inductive probe tip prevents shorting conductors -Tests include wire trace/continuity test clear/busy ringing line test and tip/ring identification -Carry case Contact Person: Nazarine Job 065 5988 608 Delivery Address: Bloemhof Electricity Complex, Block C Bloemhof Road, Bellville * SEL C662-15 USB To Serial Port Connection Cable - 15feet or equivalent. 15 foot USB-A to EIA-232 DB-9 serial port connection cable with DTE/DCE selection switch for communication with SEL electrical protection relays Minimum Technical Requirements: Length: 15 foot / 5 meter cable length Type: USB-A to EIA-232 DB-9 serial port connection cable DTE/DCE selection:Can select between data terminal equipment(DTE)and data communications equipment(DCE) 5Vdc Switch:5Vdc switch on Pin 1 to power other converters and transducers Data Rate:Up to 115200bps Contact Person: Nazarine Job 065 5988 608 Delivery Address: Bloemhof Electricity Complex, Block C Bloemhof Road, Bellville Tender Link : https://web1.capetown.gov.za/web1/procurementportal/RFQ/Details/311033
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.