GTR 103070810

Request For Quotation Purchase Of Goods (Sge)

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
103070810
Tendering Authority
Subscribe to view
Tender No
15513495
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Goods (Sge)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
13-10-2025 Closed
Work Detail
Ktpn-250/10-0.4 Kv (Vv/Hf) With Dead-End Type, With Rvo And Rlnd, Standard Version Without Transformer Hv/Lv 10Kv/0.4Kv Rated Power 250Kva (Case) Rated Currents Hv Input 31.5A, Lv Up To 400A Climate U1/Uhl1 (-45...+40ͦС, -60...+40ͦС) Protection Degree Ip23 Dimensions (Dead-End) 2800*1800*2250Mm, Weight 1000Kg Housing Design 3 Compartments, Welded Steel Housing With Painting And Ventilation Complete Set Rlnd+Opn-10, Without Transformer Purpose And Design Complete Transformer Substation For Outdoor Installation, Dead-End Type (One Input And Output) Frame - Welded Steel, Divided Into 3 Compartments: Hv, Transformer, Lv Coating: Ral Powder Paint (Series - Doors Ral5017, Panels Ral7035); Zinc Primer Possible Electrical Parameters Hv: 10Kv, Frequency 50Hz Lv: 0.4 Kv Rated Power Of The Case: 250Kva (Without Transformer) Rated Current Of Hv Inputs: ~31.5A (For 10Kv) Runn: Up To 400A Included: Input Disconnector Rlnd And Surge Arrester 10 (Lightning Arrester) On The Hv Side Without Transformer (Casing Only) - Transformer Must Be Purchased Separately Climate And Protection Climatic Version: U1 / Uhl1 (Range –45°С…+40°С / Up To –60°C) Operating Conditions: Altitude Up To 1000M, Relative Humidity Up To 80% At +20°C, Ice Up To 20Mm, Wind Up To 36M/S Protection Class: Ip23 Dimensions And Weight Typical Circuit (Ktpn 250 Dead-End): Length: 2800Mm Width: 1800Mm (Dead End) Height: 2250Mm Housing Weight (Without Transformer): Approx. 1000Kg (Dead-End) Other Characteristics Installation: Stationary, Outdoor (Open Air) Input Type: Bb/Bb (Air-To-Air) – Air Input And Output The Housing Is Equipped With Ventilation And Hatches On 4 Sides. Special Bolts And Busbars Are Provided For Grounding The Transformer Gost 14695-80 (Se), Tinned Copper Tip For Crimping Tml 50-10-12 Tdm Core Cross-Section, Mm2 - 50 Contact Rod Diameter, Mm - 10 Inner Diameter Of Shank (D1), Mm - 12 Dimensions, Mm: (Diameter)-14 L(Length)-63 R(Radius)-11 Gost 7386-80. (Se), Tinned Copper Tip For Crimping Tml 25-10-8 Tdm Core Cross-Section, Mm2 - 25 Contact Rod Diameter, Mm - 10 Inner Diameter Of Shank (D1), Mm - 8 Dimensions, Mm: (Diameter)-11 L(Length)-50 R(Radius)-11 Gost 7386-80 (Se), Tinned Copper Tip For Crimping Tml 35-12-9 Tdm Core Cross-Section, Mm2 - 35 Contact Rod Diameter, Mm - 12 Inner Diameter Of Shank (D1), Mm - 9 Dimensions, Mm: D(Diameter)-12 L(Length)-60 R(Radius)-11 Gost 7386-80 (Se), Tinned Copper Tip For Crimping Tml 120-16-17 Tdm Core Cross-Section, Mm2 - 120 Contact Rod Diameter, Mm - 16 Inner Diameter Of Shank (Dl), Mm - 18 Dimensions, Mm: (Diameter)-24 L(Length)-85 (Radius)-17 Gost 7386-80. (Se), Tinned Copper Sleeve Material Copper, Tinned Nominal Conductor Cross-Section 70Mm² Inner Diameter 11.5Mm Outer Diameter 13.5Mm Sleeve Length 100Mm Wall Thickness 1.0-1.5Mm Operating Temperature Range From -60 ͦ C To +150 ͦ C Maximum Current Up To 280-300A Type Of Installation: Crimping Increased Corrosion Protection Class (Se), Coating: Tin Plated (Tin Coating) - Protects Against Corrosion Wire Cross-Section: 16 Mm² Type Of Execution: Sleeve For Crimping (Pressed) Shape: Cylindrical Tube With Calibrated Inner Diameter Installation Method: Pressure Testing Using Press Jaws (Gmc, Pgr, Upg, Etc.) Temperature Range: -40°C To +105°C Maximum Current: ~70–80 A (Se), High Purity Electrical Copper (Cu ≥ 99.9%) Coating: Tinning (Tin Coating) - Protection Against Oxidation And Corrosion Cable Cross-Section: 35 Mm² Shape: Cylindrical Tube (Smooth, No Seam) Inner Diameter: ~7.5–8.5 Mm Outer Diameter: ~10–11 Mm Length: ~40–60 Mm (Depending On Gost/Tu) Installation: Pressure Testing Using A Hydraulic Or Mechanical Press Temperature Range: -40°C To +105°C Rated Current: Up To 160–180 A Protection Category: Increased Resistance To Moisture, Vibration And Aggressive Environments (Se), Tinned Copper Cable Sleeves Are Designed For Connecting Copper Cores Of Wires And Cables With A Cross-Section Of 10 Mm2. Tinned Copper Sleeves Are Used For Cables With Voltages Up To 10 Kv. (Se), Material Copper, Tinned Nominal Conductor Cross-Section 120Mm² Inner Diameter 14.5-14.8Mm Outer Diameter 17Mm Sleeve Length 120-130Mm Wall Thickness 1.1-1.5Mm Operating Temperature Range From -60 ͦ C To +150 ͦ C Maximum Current Up To 390-410A Type Of Installation: Crimping Increased Corrosion Protection Class (Se), Material Copper, Tinned Nominal Conductor Cross-Section 95Mm² Inner Diameter 13.3Mm Outer Diameter 15.5Mm Sleeve Length 110-120Mm Wall Thickness 1.1-1.5Mm Operating Temperature Range From -60 ͦ C To +150 ͦ C Maximum Current Up To 340-360A Type Of Installation: Crimping Increased Corrosion Protection Class (Se), Material: Copper (Cu) Coating: Tin Plated (Tin Coating) - Protects Against Corrosion Wire Cross-Section: 25 Mm² Type Of Execution: Sleeve For Crimping (Pressed) Shape: Cylindrical Tube With Calibrated Inner Diameter Installation Method: Pressure Testing Using Press Jaws (Gmc, Pgr, Upg, Etc.) Temperature Range: -40°C To +105°C Maximum Current: ~70–80 A (Se), High Purity Electrical Copper (Cu ≥ 99.9%) Coating: Tinning (Tin) - Protection Against Corrosion And Oxidation Cable Cross-Section: 50 Mm² Shape: Cylindrical Tube Without Seam Inner Diameter: ~9.5–10 Mm Outer Diameter: ~12–13 Mm Sleeve Length: ~50–70 Mm (Depending On Gost/Tu) Installation Type: Crimping With A Mechanical Or Hydraulic Press Operating Temperature Range: -40°C To +105°C Rated Current: Up To 195–210 A Protection Class: Increased Resistance To Vibration, Moisture, Aggressive Environment (Se)
Key Value
Tender Value
3,711,273 - KZT
Tender Documents
Global Tender Document
936c7f60-0e0a-4ac6-9741-a51f8bce5c52.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders