GTR 102678344

Request For Quotation Acquisition Of Organizational Equipment

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
102678344
Tendering Authority
Subscribe to view
Tender No
15463655
Financer Name
Self-Funded
Work Title
Request For Quotation Acquisition Of Organizational Equipment
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
02-10-2025 Closed
Work Detail
Resistors Wire Adjusting Adjustment For Hinged Installation. Single Dyasitor -Turnover, With A Spiral Resistive Element. Designed To Work In Electrical Circuits Of Direct And Alternating Currents. Deviation From The Functional Characteristic +-1%; +-0.3; +-0.5%. A Number Of Nominal Resistances E6. The Main Technical Characteristics Of The Resistors: The Range Of Nominal Resistances: 1 ... 47 Kohm; Nominal Power: 1W; Permissible Resistance Deviations: +-5; +-10%; Temperature Range: -60 ...+70 ° C., The Liquid Level Signaling Device Is 4-Channel. Type Of Liquid Level Control Controlled Environmental Environmental, Non -Electric Fluids Power Supply Voltage 220V Ac Method For Mounting On A Din-Rack The Number Of Entrances 4 Types Of Connected Sensors By Conductometric, Float The Voltage On The Electrodes Of The Level Of The Level Of No More Than 5 In Alternating Current With A Frequency Of 1.5 ... 2.5 Hz The Resistance Of The Controlled Environment For The Conductor Sensor Is Not More Than 850 Kohm There Are No Analog Exits Discrete/Relay Outputs Yes The Rs-485 Interface Is Not Power Consumed No More Than 2 Defense Degree, Ip Ip20 Warranty 24 Months Operating Temperature Range, ° C From -10 To +50 ° C Dimensions, Skvxg, Mm 54X95x57 Weight, Kg 0.15 Cargo Size, Place 1, Skvxg, Mm 154X195x157 Cargo Weight, Place 1, Kg 0.5, Solvent Of Gasoline. Density At 20 Degrees: 0.700 G/L. The Temperature Of The Beginning Of A Boil: 80 Degrees. The Limits Of Ignition (Close Volumetric % In The Air): The Lower Limit Of Ignition (Npv): 0.8. The Upper Limit Of Ignition (Hsv): 7.7. Self -Flaming Temperature:> 200 Degrees. Boil Temperature / Range: 78C - 113C. The Density Of Steam (Air = 1):> 1 At 101 Kpa. The Pressure Of Saturated Vapors: 6.1 Kpa (45.75 Mm Rt.St.) At 20 Grades 14.5 Kpa (108.75 Mm Rt.T.) At 38-Grad.C23.1 Kpa (173.25 Mm Rt) At 50 Degrees. Skority Of Vapor (N-Butylcetate = 1): 3Ph:-A Non-Bore. Distribution Coefficient (N-Octanol In Water): Not Defined. . Therapy In Water: Negligible Weakness. Club: 0.49 S -Sst (0.49 Mm2/S) At 40 ° C 0.67 Sst (0.67 Mm2/Second) At 25C. Freezing Temperature: <-40 ° C. Molecular Weight: Estimated. 98. Thermal Expansion Coefficient: 0.00121 Volume/Volume C, Phase Control Relay. Nominal Voltage Uno 50Hz In 400 The Minimum Permissible Linear Voltage Of 250 Maximum Permissible Linear Voltage Of 530 Power Consumption, No More Than 2 Turning Time, Tvkl, No More Than 1 Shutdown Time (Reaction), Twalk, No More Than 0.1 Maximum Switching Current Active Load: A250v50hc (As1)/Dc30v (Dc1) A 5 Maximum Community: A250v 50Hz (As1)/Dc30v (Dc1) V/W 1250/150 Maximum Switching Voltage Of 400 The Maximum Voltage Between Power Circuits And Relay Contacts In Ac2000 (50Hz - 1Min) Mechanical Wear Resistance, No Less Than Cycles 10X106 Electrical Wear Resistance, No Less Than Cycles 100,000 Number And Type Of Contacts 1 Switching Group Operating Temperature Range 0C -40 ...+55 Storage Temperature 0C -40 ...+70 Surgery From Pulses Packs In Accordance With Gost R 51317.4.4-99 (Iec/En 61000-4-4) Level 3 (2Kv/5Khz) Surgery From Overvoltage In Accordance With Gost R 51317.4.5-99 (Iec/En 61000-4-5) Level 3 (2Kv L1-L2) Climate Execution And Category Of Accommodation According To Gost 15150-69 (Without Condensate) Uhl4/Uhl2 The Degree Of Protection On The Case/By Terminals According To Gost 14254-96 Ip40/Ip20 The Degree Of Pollution In Accordance With Gost 9920-89 2 Relative Humidity Of The Air % Up To 80 (At 250C) Height Above Sea Level M 2000 Working Position In Space Arbitrary The Mode Of Operation Is Around The Clock The Overall Dimensions Are 18X90x63 Mass, No More Kg 0.05, Autonomous Power Sources (Galvanic Element) Aa -10Pcs, Aaa-10Pcs, Cr1632-10Pcs, Cr2032-10Pcs, Krona-10 Pcs, Gas Cylinder Of The Rod (Zani) Standard, Cable-Channel 20X10 Type Mounting (Main) Box Material Pvc Material Of Accessories Pvc Internal Cross -Sectional Area 131 Mm² The Number Of Partitions 0 Max Wire Diameter 8.4 Mm Installation Temperature From -5 To +60 ° C Operation Temperature From -40 To +45 ° C Surface Unprocessed The Amount In The Package 1 Pc The Size Of The Box (Skhv) 20X10 Mm Length 2000 Mm The Degree Of Protection Ip40 Color White Color Ral 9003 Double Castle Yes Rounded No Lid There Is The Width Of The Cover 20 Mm Palette White Perforated No Type Cable Channel Fire Resistance Yes Self -Shallow Yes Belogue No Self -Adhesive No Heat -Resistant No, Holder Third Hand With A Stand For A Soldering Iron And A X3 Magnifier With Led Backlight., Lubrication Silicone Aerosol, Switch (2 -Laying. Fix.) Regular Status Without Self -Return (With Fixation) Yes Hole Diameter, Mm 22 The Number Of Switching Positions 2 The Number Of Normally Closed (Nz) Contacts 1 The Number Of Normally Open (But) Contacts 1 Number Of Switching (Cracking) Contacts 0 With The Possibility Of Backlighting Power Voltage, 220 ... 230 With Self -Return (Without Fixation) The Color Of The Button Is Black Front Ring Color Gray Type Of Connecting Screw Connection Holes Height, Mm 5 Defense Degree (Ip) Ip40 From Lamps. (Light Source) Front Ring Metal With The Front Ring Yes Type Of Control Element Handle Rotation. Short (Narrow Grip) Storage Warranty Period 7 Service Life, 10 Years The Presence Of A Certificate Of Trts Yes Ekf Series Manufacturer Ekf Direct Contract Yes Warranty Life 7 Compliance With Gost/Iec/Tu Gost R 50030.5.1-2005 Degree Of Protection (Nema) 5 There Is A Barcode On Each Piece Of Goods Yes, Autonomous Power Sources (Batteries) Aaa -8Pcs, Axial Fan With Rolling Bearings. 220V As, 2200Ob/Min., 172*150*50Mm, 255M3/H, 50Db, Rolling Bearing, Type Of Output-Lumping, 0.22 A, Operating Voltage Range 220-240V, Operating Temperature Range -10 ...+60 ° C. Material Building Al+ Ra66; The Impeller Is Rvt. The Center Distance Is 162Mm, The Development For Refusal (Average) -50000. Relative Humidity 0 ... 95%. Frequency 50/60Hz., Switch (3 Position.). Regular Status Without Self -Return (With Fixation) Yes Hole Diameter, Mm 22 The Number Of Switching Positions 3 The Number Of Normally Closed (Nz) Contacts 0 The Number Of Normally Open (But) Contacts 2 Number Of Switching (Cracking) Contacts 0 With The Possibility Of Backlighting Power Voltage, 220 ... 230 With Self -Return (Without Fixation) The Color Of The Button Is Black Front Ring Color Gray Type Of Connecting Screw Connection Holes Height, Mm 5 Defense Degree (Ip) Ip40 From Lamps. (Light Source) Front Ring Metal With The Front Ring Yes Type Of Control Element Handle Rotation. Short (Narrow Grip) Storage Warranty Period 7 Service Life, 10 Years The Presence Of A Certificate Of Trts Yes Ekf Series Manufacturer Ekf Direct Contract Yes Warranty Life 7 Compliance With Gost/Iec/Tu Gost R 50030.5.1-2005 Degree Of Protection (Nema) 5 There Is A Barcode On Each Piece Of Goods Yes, Connector Rj-11 (6P4c) Weight 0.08 Kg Guarantee 12 Months Contact Material Phosphate Bronze With 3U Spray Diameter Of Conductors, Mm 0.51-0.40 (24-26 Awg) Bandwidth, Mhz 16 The Execution Is Unexplored Polycarbonate Case Material Type Of Knives For One -Core Cable Operation Temperature, ° C -30: 80 Storage Temperature, ° C -40: 70 Number In Packaging 100 Type Of Connector Rj-11 Category 3, Ultraviolet Protective Transparent Glasses (4,2), Manometer Ekm (Or Similar) Gost 2405-88. The Diameter Of The Case Ø 160 Mm Accuracy Class 1.5 Pressure Range From 0 To 10 Kgf/Cm2 Introductory Thread M20x1.5 The Location Of The Fitting Radial The Degree Of Dust Protection Ip40 Flange Absent Interdemetional Interval 1 Year Climate Performance U2 Corps Material Aluminum Alloy The Material Of The Fitting Copper Alloy; Steel Glass Cast The Temperature Of The Measured Medium Up To +150 S Electro -Contact Prefix Execution Of Iii, Iv, V (By Default), Vi Gost 13717-74 That 25-02-31-75 The Verification Methodology Mi 925-85 The Number Of The State Registry 4041-74 Guaranteed Shelf Life 6 Months From The Date Of Manufacture Warranty Life 12 Months (From The Date Of Commissioning Of The Device,, Pressure Relay. Du, Inch 1/4 Differential, Bar 0.7 ... 4 Pressure Settings Range, Mpa -0.02 ... 0.8 Operating Temperature Range, ° C -10 ...+110 Protection Class Ip44, Phase Control Relay. Nominal Linear Voltage (Inter -Phase) Voltage Of Alternating Current 50 Hz, In 400 Permissible Fluctuations In The Supply Voltage From The Nominal Value +10%, -15% Relay Triggering (Output Contacts) With A Single -Phase Voltage Decrease (With Ufn In Two Other Phases) Usr. Fn At Least 0.7Ufn Relay Triggering (Output Contacts) When A One, Two Or Three Phases Is Cut Relay Triggering (Output Contacts), When The Phase Alternation Is Revealed, Works Operation Time (Regulation Limits) From 0.1 To 10 S The Average Main Error In The Relay Operation Time In The Regulator’S Extreme Positions, % Not More Than ± 30 Mass Relay, Kg, No More Than 0.3 The Number Of Closing Contacts 1 The Number Of Blurry Contacts 1 Mechanical Wear Resistance Of 10 In 6 Degrees Of Cycles Ip40 Shell Protection Degree The Degree Of Protection For The Ip10 Connector, Universal Telephone Socket. Gost 8810-81. Installation Invoice (Open) The Number Of Posts 2 Type Of Configuration Rosette Assembly Frame Not Required (It Comes With It) Grounding No Protective Curtains No The Degree Of Protection Ip20 Lid No Material Abs-Plastic The Number Of Nests 2 The Connector Rj14 Color White Type Of Sockets Jack Telephone Modular No The Width Of The Device 58 Mm The Height Of The Device 42 Mm The Depth Of The Device 25 Mm, Autonomous Power Sources (Batteries) Aa -8Pcs
Key Value
Tender Value
643,600 - KZT
Tender Documents
Global Tender Document
702c6db3-dfa1-4e67-989e-2a99510208c7.html
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders