Commercial Ovens – Pr1055091 Pyrolyseofen (Ov, Pr1055091). The Fraunhofer Ikts Plans The Purchase Of A Resistance -Heated Cold Wall Furnace For Pyrolyzing/Outgrowing Pre -Shaped Ceramic Components. The Work Will Take Place In Nitrogen As Well As In Argon Or In A Mixture Of Both Process Gases. The Oven Must Be Able To Be Evacuated To A Value Of 0.5 Mbar Or Better Before The Process Start. The Thermal Process Takes Place Under A Relative Pressure Or In The Partial Vacuum At More Than 100 Mbar Up To A Maximum Of 900 Mbar. The Maximum Accessible Operating Temperature Of The Oven Is At Least 1,300 ° C. The Temperature Measurement Takes Place With The Help Of Suitable Thermo Elements. Each Heating Zone Of The Oven Is Regulated Separately. The Oven Has Two Fixed Levels For Storing Components. The Insertion Of The Components That Are Located On An Surface With An Area Of At Least 900 X 900 Mm Must Be Brought Into The Oven With This Surface And Using A Suitable Chargier Aid. The Total Installation Height Of The Pad And The Components On It Is A Maximum Of 350 Mm. On The Basis Of This Information, The Dimensions Of The Two Overlaps, Fixed, Stalled Levels Are To Be Interpreted In Order To Enable Safe Insertion And Output. Unknown Hydrocarbon Compounds Are Released In Pyrolysis/Escape. The Oven Must Be Equipped With An Electrically Heated Thermal Afterburning (Tnv), Which Can Burn At Least 5 Kg/H Hydrocarbons According To The Currently Valid Regulations And Laws. This Tnv Is To Be Placed As Close As Possible To The Oven. The Connection Line Between The Oven And The Tnv Can Be Adjusted To At Least 180 ° C. The Installation Location With A Maximum Available Area Of 5,800 X 5,325 Mm Is Located On The Ground Floor. There Is No Ceiling Load At The Installation Location. The Area Of All Assemblies Of The System, The Areas For Service On The System And All The Necessary Operating Surfaces Must Be Within The Available Installation Space. The Details Can Be Seen In The Attached Parking Space Plan. Access To The Installation Surface For Inserting The System Is Via A Ramp And Through A Door. The Smallest Passage Width Is 2,350 Mm And The Smallest Passage Height To The Location 2,200 Mm. All Media (Electrics, Process Gases, Cooling Water, Compressed Air) Or Suction Points (Exhaust Air Process Gas, Exhaust Air Vacuum Pump), Which May Be Required, May Be At The Parking Space. Its Connection To The System Will Take Place From Above. Accordingly, A Transfer Point For Connecting All Media From Above (From The Hall Corner) Must Be Provided. For Details, Please Refer To The Tender Documents.
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.