Quotation are invited for Tools Delivery Date: 2025/11/28 Delivery To: Electricity - Ndabeni RED1 Plant / PH: 511 0410 Delivery Address: 0 BLOCK A1,BLOEMHOD ROAD, BELLVILLE Closing Date: 2025/09/26 Closing Time: 12:00 PM Description: 1 each x fluke 179 1 each x clamp meter Specification: * Fluke 179 equivalent AC Voltage, True-rms 0.1 mV to 1000V (1 kHz) DC Voltage 0.1 mV to 1000V Continuity Beeper guaranteed on 25 O, guaranteed off > 250 O; detects opens or shorts of 250 µs or longer. Resistance 0.1O to 50.00 MO Diode Test 2.400V Capacitance 1 nF to 9999 uF AC Current, True-rms 0.01 mA to 10.00A (20.00 A over-range for 30 seconds) DC Current 0.01 mA to 10.00A (20.00 A over-range for 30 seconds) Frequency 2 Hz to 50 kHz Temperature (179 Only) -40 ºC to +400 ºC; -40 ºF to +752 ºF Basic dc voltage accuracy 0.15% (175) 0.09% (177 & 179) Basic ac voltage accuracy 1.0% Nominal Specifications Detailed Specifications Accuracy ± ( [ % of Reading ] + [ Counts ] AC Volts 2 600.0 mV 0.1 mV 1.0 % + 3 1.0 % + 3 1.0 % + 3 6.000V 0.001V (45 Hz to 500 Hz) (45 Hz to 500 Hz) (45 Hz to 500 Hz) 60.00V 0.01V 600.0V 0.1V 1000V 1V 2.0 % + 3 2.0 % + 3 2.0 % + 3 (500 Hz to 1 kHz) (500 Hz to 1 kHz) (500 Hz to 1 kHz) DC mV 600.0 mV 0.1 mV 0.15 % + 2 0.09 % + 2 0.09 % + 2 DC Volts 6.000V 0.001V 0.15 % + 2 0.09 % + 2 0.09 % + 2 60.00V 0.01V 600.0V 0.01V 1000V 1V 0.15 % + 2 0.1 % + 2 0.1 % + 2 Continuity 600O 1O Meter beeps at 25 O, beeper turns off at > 250 O; detects opens or shorts of 250 ms or longer. Ohms 600.0O 0.1O 0.9 % + 2 0.9 % + 2 0.9 % + 2 6.000 kO 0.001 kO 0.9 % + 1 0.9 % + 1 0.9 % + 1 60.00 kO 0.01 kO 0.9 % + 1 0.9 % + 1 0.9 % + 1 600.0 kO 0.1 kO 0.9 % + 1 0.9 % + 1 0.9 % + 1 6.000 MO 0.001 MO 0.9 % + 1 0.9 % + 1 0.9 % + 1 50.00 MO 0.01 MO 1.5 % + 3 1.5 % + 3 1.5 % + 3 Diode test 2.400V 0.001V 1 % + 2 Capacitance 1000 nF 1 nF 1.2 % + 2 1.2 % + 2 1.2 % + 2 10.00 µF 0.01 µF 1.2 % + 2 1.2 % + 2 1.2 % + 2 100.0 µF 0.1 µF 1.2 % + 2 1.2 % + 2 1.2 % + 2 9999 µF 3 1 µF 10 % typical 10 % typical 10 % typical AC Amps 60.00 mA 0.01 mA 1.5 % + 3 1.5 % + 3 1.5 % + 3 (True-rms) 400.0 mA 0.1 mA (600 mA for 18 hrs) 0.001A 6.000A (45 Hz to 1 kHz) 10.00A 0.01A (20A for 30s) DC Amps 60.00 mA 0.01 mA 1.0 % + 3 1.0 % + 3 1.0 % + 3 400.0 mA 0.1 mA (600 mA for 18 hrs) 6.000A 0.001A 10.00A 0.01A (20A for 30s) Hz 99.99 Hz 0.01 Hz 0.1 % + 1 0.1 % + 1 0.1 % + 1 (AC- or DC- 999.9 Hz 0.1 Hz coupled, 9.999 kHz 0.001 kHz V or A 4, 5 input ) 99.99 kHz 0.01 kHz Temperature -40 °C to +400 °C 0.1 °C NA NA 1 % + 1.0 °C -40 °F to +752 °F 0.1 °F 1 % + 1.8 °F MIN MAX AVG For DC functions, accuracy is the specified of the measurement function ± 12 counts for changes longer than 275 ms in duration. For AC functions, accuracy is the specified of the measurement function ± 40 counts for changes longer than 1.2 s in duration. 1. All AC voltage and AC current ranges are specified from 5 % of range to 100 % of range. 2. Crest factor of = 3 at full scale up to 500 V, decreasing linearly to crest factor = 1.5 at 1000 V. 3. In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % for all models. 4. In mA and A ranges, frequency measurement is specified to 30 kHz. 5. Frequency 10 kHz are not specified in 600 mV AC, 60 mA AC, and 6 A AC ranges. Contact Person: Ivor Crafford 021 444 3869 Ivor.Crafford@capetown.gov.za * Clamp Meter 18" or equivalent Maximum voltage between any terminal and earth ground 1000 V Battery type 2 AA alkaline batteries, NEDA 15A, IEC LR6 Temperature Operating: -10 °C to +50 °C (14 °F to + 122 °F) Storage: -40 °C to +60 °C (-40 °F to + 140 °F) Operating humidity Non condensing ( 10 °C (50 °F)), =90 % RH (at 10 °C to 30 °C (50 °F to 86 °F)), =75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), =45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) Altitude Operating: 3,000 m (9,842 ft) Storage: 12,000 m (39,370 ft) Dimensions 24.9 cm (9.8 in) x 8.5 cm (3.3 in) x 4.5 cm (1.7 in) Weight 395 g (13.9 oz) Jaw opening 34 mm (1.3 in) Flexible current probe diameter 7.5 mm (.29 in) Flexible current probe cable length (head to electronics connector) 1.8 m (70.8 in) Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V IP rating IEC 60529: IP30, non-operating Radio frequency certification FCC ID:T68-FBLE IC:6627A-FBLE Contact Person: Ivor Crafford 021 444 3869 Ivor.Crafford@capetown.gov.za Tender Link : https://web1.capetown.gov.za/web1/procurementportal/RFQ/Details/309905
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.