Bids Are Invited For Emergency Acquisition In Installments Of Materials (Reagents) Compatible With The Device (Sinnow Sx260 Biochemical) To The Municipal Hospital Laboratory To Meet The Needs Of The Carnaíba Municipal Health Fund - Pe.
Bids Are Invited For Emergency Acquisition In Installments Of Materials (Reagents) Compatible With The Device (Sinnow Sx260 Biochemical) To The Municipal Hospital Laboratory To Meet The Needs Of The Carnaíba Municipal Health Fund - Pe.
Uric Acid (Uod -Pap) - Colorimetric Enzyme Method For The Determination Of Uric Acid. Enzyme Reagent: 02 100 Ml Vials Each, Aqueous Solution Containing Ph 7, 20, Uricase ³ 120 U/L, Peroxidase ³ 1000 U/L, 4-Aminoantipirin 1, 0 Mmol/L, 0, 60 Mmol/L And Azidasod 0, 1 G/Dl. Conserve Between 2 And 8 ° C. Standard: 01 Phrascocom 5, 0 Ml, Containing Uric Acid 8 Mg/Dl (0, 476 Mmol/L) In Aqueous And Azidal Sodium Solution 0, 1 G/Dl. Conserve Between 2 And 8 ° C. Validity At Least 18 Months. Kit. Note: Compatible With The Sinnowasx260 Automatic Biochemical Analyzer., Albumin - Monoreagent Kit For The Determination Of Albumin In The Serum. With Pattern Included In The Kit, Methodology: Green Bromocresolsensitivity: 0, 27 G/Dl, Linearity Of: 6 G/Dl, Presentation: R1 1X250ml + Std 3Ml, Linearity Up To 6G/Dl. 250Ml Mime Quantity. Note: Compatible With Automatic Analyzer Sinnow Sx260., Alpha-1 Glycoprotein Acid-Kit Intended To Determine The Alpha-1 Glycoprotein Acid In Serum And Plasma. Methodology: Turbidimetry; Sensitivity: 1, 55 Mg/Dl; Linearity Of: 250 Mg/Dl; Presentation: R1 1 × 25Ml. Note: Compatible With The Biochemical Analyzer Sinnow Sx260., Alt -Tgp - Kit For Quantitative Determination Of Tgp Activity In The Serum. Methodology: Uv - No Pyridoxal Phosphate. Sensitivity: 5.15 U/L, Linearity Of: 350 U/L, Presentation: R1: 4X40ml And R2: 4X10ml. Minimum Amount Of 200Ml. Note: Compatible With Automatic Analyzer Sinnow Sx260., Ast -Tgo - Kit For Quantitative Determination Of Tgo Activity In Serum. Methodology: Uv - No Pyridoxal Phosphate, Sensitivity: 3.05 U/L, • Linearity Of: 440 U/L. Presentation R1: 4X40ml And R2: 4X10ml. Minimum Amount Of200ml. Note: Compatible With The Sinnow Sx260 Automatic Biochemical Analyzer., Direct Bilirubin - Kit Intended For The Determination Of Direct Bilirubin In Serum And Plasma (Heparin And Edta). Methodology: Dca (Dicloroaniline Diazoted). Reaction: Final Point. Presentation R1 1X80ml + R2 2X12ml Linerality. At Minimum 50Mg/Dl. Note: Compatible With The Sinnow Sx260 Automatic Biochemical Analyzer., Total Bilirubin - Kit Intended For The Determination Of Total Bilirubin In Serum And Plasma (Heparin And Edta). Methodology: Dca (Dicloroaniline Diazoted). Reaction: Final Point. Presentation R1 1X80ml + R2 2X12ml Linerality. At Least 20Mg/Dl Note: Compatible With The Sinnowasx260 Automatic Biochemical Analyzer. Methodology: Galg2 - Cnp, Sensitivity: 3.167 U/L, Linearity Of: 1200 U/L, Presentation: R1: 4X15ml. Minimum Amount Of 60Ml. Note: Compatible With The Sinnow Sx260 Automatic Biochemical Analyzer., Calcium Asx - Monoreagent Kit For The Determination Of Calcium In Serum, Plasma And Urine. With Pattern Included In The Kit. Methodology: Arsenazo Iii. Sensitivity: 0.94 Mg/Dl, Linearity From: 20 Mg/Dlapress: R1: 4X50ml +Std 1X4ml. Minimum Amount Of 200Ml., Iron Fixation Capacity (Ibc) - Kit Intended To Determine The Iron Fixing Capacity In The Serum. Automated Method, Final Point Reaction. Compadrão Included In Kit. Volume: R1 2 × 50Ml - R2 2 × 15Ml - Cal 1 × 3Ml. Linearity: 450 Μg/Dl. Minimum Quantity Of130ml. Note: Compatible With The Sinnow Sx260 Automatic Biochemical Analyzer.
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.