Bound Cateters For Reading 0.014. Btk Two -Lobed Cylinder Catheter Rx System, Compatibility With A Conductor Of 0.014 ”, X -Ray Contrast Markers, Double, Hydrophilic Coating Throughout, 3.0 X2.5X 210 Cm. Nomin. - 8 Atm, Pressure Rupture - 14 Atm. Low Top Profile - 0.017”., Channel Catheter 0.018 Coaxial Two -Feature Peripheral Cylinder Catheter On The Otw Delivery System. The Material Of The Cylinder With Increased Flexibility While Maintaining A High Valve Pressure. Hydrophilic Coating Of The Cylinder And The Distal Part Of The Chaft. Shaft Material With A High Level Of Patency And Resistance To Bends, Combined With Exceptional Flexibility. Shaft: Length - 90, 130 Cm; Ø-3.9-4.2F. Compatibility With An Introduct Of 4F --5F, With 0.018 ’’ Conductor. 2 Puffed With Profile 0 Platinoiridium Marker Along The Edges Of The Cylinder. Ballon Length (Mm): 200 - For Diameters 5.0 (130 Cm). Complains: Nominal Pressure (Np) - 6 Atm, Calculated Rupture Pressure (Rbp): 14 Atm. (Ø 4.0; 5.0; 6.0Mm), 12Atm. (Ø 7Mm)., A Catheter To Support The Passage Of Chronic Occlusion Is A Transparent Microcateter With A Hole On A Distal End Moving Along The Conductor 0.014. The Proximal End Has A Standard Luer Adapter For Lightweight Accessories. Catheter Is Designed To Pass Total Chronic Occlusion. The Catheter Has 3 Markers Placed Between The Layers Of The Catheter. It Has 2 Layers: Made Of Particularly Durable Material And Has A Hydrophilic Coating On The Distal End, For 40 Cm; 0.035 ). Markers Have An Increased 50% Length. The Handle Of The Form Guppy. Distal Profile: For 0.014 - 2F; 0.018 - 2.2F; 0.035 - 3.8F. Proximal Profile: 0.014 - 3.0 F; 0.018 - 3.4 F; 0.035 - 4.8F. Length 135 Cm., Bound Cateters For Reading 0.035. Peripheral Cylinder Catheter, A Shipping Coaxial System “Conductor. Stable To Fractures And Crushing, A Delivery System From The Pebax Blend Material. Soft Conical Atravmatic Tip With A Bevel Of 450 For The Best Passage Of Stenosis. The Material Of The Nylon -12 Cylinder, The Gap Pressure Is 20 - 10 Atm, Depending On The Diameter. The Presence Of Two Obli-Contrast Markers At The Edges Of The Cylinder., Self -Disclosed Stent System. Nitinol Self -Disclosure Stent. Compatible With 0.035 Conductor. Spiral Arrangement Of Cells. Tantalum Markers At Each End Of The Stent. Open Cells. Not Expanding The Ends Of The Stent. Protection System From Interchangeing The Stent E.X.P.R.T. When Opening. Zero Shortening Of The Stent. All Sizes Of The Stent Are Compatible With 6 Fr Interodista. Profile Stent 0.079. The Length Of The Delivering Catheter Is 120 Cm And 80 Cm. The Manufacturers Guarantee From The Mechanical Fracture To The Installed Stent For At Least 2 Years. The Possibility Of Choosing Stents With Increased Flexibility Or With Increased Radial Strength Of The Size Of The Stent With Increased Flexibility: Diameter - 8; Length: 120 Mm, Stent For Carotid Arteries. A Rapidly Replaced Protection System Against Distal Embolism With A Wicker Nitinol Filter With A Heparin Coating. Independent Rotation Of The Filter On The Wire. The Transverse Profile 3.2Fr. Compatible With Conductors 0.014 Or 0.018. The Length Of The Conductor Is 320Cm With The Possibility Of Shortening Up To 190Cm And The Use Of The Remaining Conductor For Quick Navigation Through The Rx Port. The Platinum Wire At The End Of The Conductor To Provide The Best X -Ray Contract. Golden Wire Of Mounting In The Filter Openings To Determine The Degree Of Opening And Position Of The Filter. The Filter Must Completely Clean The Delivering Catheter During Delivery. When Removing, The Filter Must Completely Clean The 4.2Fr Catheter. The Catheter For Delivery And Removal Is Included In The Kit. Filter Size: 6 Mm 1 Piece., Rukan Upp 3.5Mm. Rolonny Roofing Waterproofing Material Rukan For The Device And Repair Of Roofs With A Small Bias. The Material Is Made On The Basis Of Fiberglass Resistant To Decay With A Bitumen Binder Applied On Both Sides. The Lower Sides Are Covered With A Light -Melted Polymer Film, The Upper One Is Protected By Coarse -Grained Mineral Sprinkling. The Heat Resistance Of The Material Is Up To +70 C. The Installation Of The Material Is Carried Out Using A Propane Burner, Which Ensures Uniformity, A High Degree Of Waterproofing, Strength And Durability Of The Coating. The Base Is Fiberglass, Bitumen Binder. Type Of Protective Coating, The Upper Side-Granustine Mineral Sprinkling. Length 10 M, Shirin-1 M. Gost 30547-97. Customer-Economic Department, The Stent Is A Cylinder -Extensive Peripheral. Stent Stainless Steel, A Cylinder -Elapsible Matrix. Mounted On A Delivery System Compatible With 6/7 Fr Introder And 0.035 ”By A Conductor. Tantalum Markers At Each End Of The Stent. Profile - 0.079”. The Operating Length Of The Catheter Is 80. Normal Pressure In The Cylinder Is 8 Atm., The Maximum Is 12 Atm. Stenta Diameter 8. Length: 57 Mm, Operating Length Of The Catheter 135 Cm - 1 Piece, Channel Catheter 0.018 , Coaxial Two -Luminous Peripheral Cylinder Catheter On The Otw Delivery System. Bullboard Material With Increased Flexibility While Maintaining A High Valve Pressure. Hydrophilic Lfc Covering The Cylinder And Distal Part Of The Shaft. Shaft Material With A High Level Of Patency And Resistance To Bends, In Combination With An Exceptional Flexibility: Length - 90, 130 And 180Cm - 4F. (Np): The Calculation Of The Gap (Rbp): 22 Atm., Stent For Carotid Arteries. A Rapidly Replaced Protection System Against Distal Embolism With A Wicker Nitinol Filter With A Heparin Coating. Independent Rotation Of The Filter On The Wire. The Transverse Profile 3.2Fr. Compatible With Conductors 0.014 Or 0.018. The Length Of The Conductor Is 320Cm With The Possibility Of Shortening Up To 190Cm And The Use Of The Remaining Conductor For Quick Navigation Through The Rx Port. The Platinum Wire At The End Of The Conductor To Provide The Best X -Ray Contract. Golden Wire Of Mounting In The Filter Openings To Determine The Degree Of Opening And Position Of The Filter. The Filter Must Completely Clean The Delivering Catheter During Delivery. When Removing, The Filter Must Completely Clean The 4.2Fr Catheter. The Catheter For Delivery And Removal Is Included In The Kit. Filter Size: 5Mm, Balon Catheter Peripheral With A Medicinal Coating 0.014 Bound Catheter (0.014ʺ Otw, 0.018ʺ Otw, 0.035ʺ Otw), Covered With Sylolymus, Cylinder Diameter (Mm) 2.00, Cylinder Length (Mm) 120. Covered A Cylinder Catheter For A Balloon Catheter Consists Over-The-Wire (Otw-A Conductor Delivery System) With A Coating, An Unexplored Composition Containing A Sylolymus Drug As An Active Ingredient In The Auxiliary Substance Phospholipid. It Uses A Patented Nanolute Coating Technology. Ptas Unpatented Name Is A Cylinder Catheter Covered With Sylolymus., Balon Catheter Peripheral With A Medicinal Coating 0.035 Bound Catheter (0.014ʺ Otw, 0.018ʺ Otw, 0.035ʺ Otw), Covered With Sylolymus, Cylinder Diameter (Mm) 2.50, Cylinder Length (Mm) 120. Cleaned Catheter Covered With A Cylinder Catheter Consists Over-The-Wire (Otw-A Conductor Delivery System) With A Coating, An Unexplored Composition Containing A Sylolymus Drug As An Active Ingredient In The Auxiliary Substance Phospholipid. It Uses A Patented Coating Technology To Transfer The Drug To The Wall Of The Vessel. Ptas Unpatented Name Is A Cylinder Catheter Covered With Sylolymus., A Catheter To Support The Passage Of Chronic Occlusion Is A Transparent Microcatter With A Hole On The Distal End, Moving Along The Conductor 0.018. The Proximal End Has A Standard Luer Adapter For Lightweight Accessories. Catheter Is Designed To Pass Total Chronic Occlusion. Catheter Has 3 Markers Placed Between The Layers Of The Catheter. It Has 2 Layers: Made Of Particularly Durable Material And Has A Hydrophilic Coating On The Distal End, For 40 Cm; 0.035 ). Markers Have An Increased 50% Length. The Handle Of The Form Guppy. Distal Profile: For 0.014 - 2F; 0.018 - 2.2F; 0.035 - 3.8F. Proximal Profile: 0.014 - 3.0 F; 0.018 - 3.4 F; 0.035 - 4.8F. Length 135 Cm., Conductor Catheter (Cerebral) 8F. Mr 1. Conductive Catheter For Intervention Procedures On Coronary And Peripheral Arteries. Various Options For Configuration Of The Ends Of The Catheter: Judkins Left, Judkins Right, Super Back Up Support, Amplatz, Multi -Purpose, Coronary Bypass, Internal Mammary, El Gamal, Hockey Stick, Ultimate. The Length Of The Catheter Is 100 Cm. A Two -Layer Reinforced Catheter Wall. Stainless Steel Braid Material. The Inner Layer Of The Catheter Is Teflon And The Outer Patented Polymer Coating. Hybrid Technology Braids To Increase The Internal Clearance. The Material Of The Outer Layer Of Pebax. Five Zones Of Change In The Rigidity Of The Catheter From The Proximal End To The Distal. Narrowing Of The Tip Of The Catheter. Dimensions 8 F. The Internal Clearance Of At Least 0.088 (2.2 Mm) For Catheter 8F). The Outer Diameter Is At Least 0.105 (2.6 Mm) For Catheter 8F). The Presence Of Catheter With Both Side Holes (To Preserve Throughput) And Without Them. The Size Of The Tip Is 3.0, 3.5, 4.0, 5.0, 6.0. Manage Of 1: 1 Axis Resistance To Twisting And Axial Breakdown. The Material Of The Tube Is An Atrombogen, With High Fluidity. The Presence Of An X -Ray Contact Mark On The Distal End Of The Catheter., Distal Embolism Protection System. Self -Disclosed Nitinol Stent On The Delivery System With Rx Port At A Distance Of 28 Cm From The Tip Of The Catheter. Tantalum Markers At Each End Of The Stent. Open -Type Cells. Not Expanding The Ends Of The Stent. Protection System From Stent Account Ex.P.R.T. When Opening. Zero Shortening Of Stent. Stent 0.0088 Wall Thickness. Compatibility With A Conductor Of 0.014. The Working Length Of A Delivering Catheter Is 135 Cm. Compatible With A Conductor Of 0.014 . Two Stent Options Are Possible: Anatomically Narrowing (“Bottle -Like”) Shape And Straight Line. Size For Stent Of A Bottle -Shaped Shape: Stent Diameter 8X6, Length 40 Mm. Size For Stent Direct Form: Stent Diameter - 6; 7; 8; 9; 10, Length - 20; 30; 40; 60 Mm., Bound -Mounted Catheters 0.014 Two -Light Cylinder Catheter Otw System, Proximal Part Of The Shaft 1.24 , Distal - 0.99, Compatibility With The Conductor .014 , Markers Of X -Ray -Contrast, Double, Tape Pressure - 7-10 Atm, Gap Pressure - 18 Atm, Coverage Of Hydrophilic Throughout, Cylinder -Diameter - Diameter Of The Cylinder - Diameter Of The Cylinder 1.5 Mm, The Length Of The Cylinder Is 40 Mm, The Length Of The Catheter Is 150 Mm., Channel Catheter 0.018 , Coaxial Two -Luminous Peripheral Cylinder Catheter On The Otw Delivery System. Bullboard Material With Increased Flexibility While Maintaining A High Valve Pressure. Hydrophilic Lfc Covering The Cylinder And Distal Part Of The Shaft. Shaft Material With A High Level Of Patency And Resistance To Bends, In Combination With An Exceptional Flexibility: Length - 90, 130 And 180Cm - 4F. Pressure: 8 Atm., Channel Catheter 0.018 Coaxial Two -Feature Peripheral Cylinder Catheter On The Otw Delivery System. The Material Of The Cylinder With Increased Flexibility While Maintaining A High Valve Pressure. Hydrophilic Coating Of The Cylinder And The Distal Part Of The Chaft. Shaft Material With A High Level Of Patency And Resistance To Bends, Combined With Exceptional Flexibility. Shaft: Length - 90, 130 Cm; Ø-3.9-4.2F. Compatibility With An Introduct Of 4F --5F, With 0.018 ’’ Conductor. 2 Puffed With Profile 0 Platinoiridium Marker Along The Edges Of The Cylinder. Ballon Length (Mm): 80 - For Diameters 7.0 (130 Cm). Complains: Nominal Pressure (Np) - 6 Atm, Calculated Rupture Pressure (Rbp): 14 Atm. (Ø 4.0; 5.0; 6.0Mm), 12Atm. (Ø 7Mm)., Bound -Mounted Catheters 0.014 Two -Light Cylinder Catheter Otw System, Proximal Part Of The Shaft 1.24 , Distal - 0.99, Compatibility With The Conductor .014 , Markers Of X -Ray -Contrast, Double, Tape Pressure - 7-10 Atm, Gap Pressure - 18 Atm, Coverage Of Hydrophilic Throughout, Cylinder -Diameter - Diameter Of The Cylinder - Diameter Of The Cylinder 2.5 Mm And 2.0 Mm Length - 120 Mm, The Length Of The Catheter Is 150 Mm., Bound Cateters For Reading 0.035. Peripheral Cylinder Catheter, A Shipping Coaxial System “Conductor. Stable To Fractures And Crushing, A Delivery System From The Pebax Blend Material. Soft Conical Atravmatic Tip With A Bevel Of 450 For The Best Passage Of Stenosis. The Material Of The Nylon -12 Cylinder, The Gap Pressure Is 20 - 10 Atm, Depending On The Diameter. The Presence Of Two Enthusiastic Markers On The Edges Of The Cylinder.