Bids Are Invited For Acquisition Of A Digital Fixed X-Ray Device, With Direct Digital Technology, Intended To Meet The Demands Of Diagnostic Imaging, Aiming To Meet The Needs Of The Virginia Colaço Dias Hospital And Maternity Hospital.

Tender Detail

101497661
005/2025
Self-Funded
Bids Are Invited For Acquisition Of A Digital Fixed X-Ray Device, With Direct Digital Technology, Intended To Meet The Demands Of Diagnostic Imaging, Aiming To Meet The Needs Of The Virginia Colaço Dias Hospital And Maternity Hospital.
NCB
South America
BRIC,G20
23-09-2025

Work Detail

X -Ray Apparatus - Digital Fixed - Minimum Descriptions: Equipment With Digital Technology (Flat Panel Detector) X -Ray Emitter For Image Clinical Diagnostic Purposes. High Frequency Microprocessor Generator. Power Of At Least 50 Kw. Variable Voltage That Minimally Meets The 40 Kv Range To 125 Kva Greater. Variable Current Between 10 Ma To 500 Ma Or Larger. Minimum Exposure Time Of 5Ms Or Lower, 4S Or Larger. With But Variable In The Range Of 10 Or Lower To 500 But Or Larger. X-Ray Tube, 0.6Mm Thin Focus And Thick Focus Equal To Or Greater Than 1, 0 Mm; Minimum Revolving Anode 3,000 Rpm To 60 Hz; Minimum Thermal Capacity Of The 150 Khu Anode. Insertion Of Additional Ass Or Al. Stative To Emitting Door With Their Proper Characteristics; Column With Longitudinal Displacement From 125 Cm; Rotation Of The Pipe On Horizontal Axis Of +/- 90 Degrees With Locks At 0 Degrees, +/- 90 Degrees; Luminous Diaphragm With Manual Or Automatic Collimation; Electromagnetic Brake System. Bucky Table With Antidifuser Of At Least 40Lp/Cm, Focus Of At Least 100 Cm, 8: 1 Or 10: 1; Floating Top With Minimum Dimensions Of 200 X 65 Cm, With Total Minimum Longitudinal Displacement Course Of 72 Cm And Total Transverse Side Displacement Course, Approximately 20 Cm; Electromagnetic Brake System. Weight Capacity Supported By The Table Of At Least 150 Kg. Bucky Mural Vertical Displacement Referenced At The Center Of The Grid Between 60 Cm (Or Smaller) And 170 Cm (Or Larger) From The Floor, Approximately With Electromagnetic Or Mechanical Brake System. Mural With Antidifuser Of At Least 40Lp/Cm, Focal Distance Between 100 Cm And 180 Cm; With Location/ Centralization Printed On Buckys Top. Flat Detector With Approximate Dimensions Between 34 X 42 Cm Or Larger. Wire Or Wire Or Wire (Mobile) And Cesium Iodide Striking, Which Enables Table Tests, Mural Bucky Or Offspring, Stretcher And Wheelchair. Active Matrix Of At Least 1990 X 2048 Pixels. Post Pro Image Depth

Key Value

Tender Value
3,45,987 - BRL

Attachment

FileName File Description
Global Tender Document Tender Notice
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail