Copper Pipe Refined, Inner Diameter Of At Least 10 Mm. Material Copper Seamless Pipe Section Is Round. The Thickness Of The Pipe Wall Is At Least 0.8 Mm. The Length Is At Least 20M. Gost 28548-90, Copper Pipe Refined, Inner Diameter Of At Least 6 Mm. Material Copper Seamless Pipe Section Is Round. The Thickness Of The Pipe Wall Is At Least 0.7 Mm. The Length Is At Least 20M. Gost 28548-90, Bound Cateters For Reading 0.035. Peripheral Cylinder Catheter, A Shipping Coaxial System “Conductor. Stable To Fractures And Crushing, A Delivery System From The Pebax Blend Material. Soft Conical Atravmatic Tip With A Bevel Of 450 For The Best Passage Of Stenosis. The Material Of The Nylon -12 Cylinder, The Gap Pressure Is 20 - 10 Atm, Depending On The Diameter. The Presence Of Two Enthusiastic Markers On The Edges Of The Cylinder., The Stent Is A Cylinder -Extensive Peripheral. Stent Stainless Steel, A Cylinder -Elapsible Matrix. Mounted On A Delivery System Compatible With 6/7 Fr Introder And 0.035 ”By A Conductor. Tantalum Markers At Each End Of The Stent. Profile - 0.079”. The Operating Length Of The Catheter Is 80. Normal Pressure In The Cylinder Is 8 Atm., The Maximum Is 12 Atm. Stenta Diameter 8. Length: 37 Mm Operating Length Of The Catheter 135 Cm, Channel Catheter For Reading. Coaxial Two -Lobed Cylinder Balloon Catheter For Peripheral Angioplasty On The Delivery System (Otw), Compatible With 0.035 “Conductor. Special Material Of The Cylinder Combines Ultra -Thin Walls And Stability To Scratches. Hydrophilic (Lfc) Covering Of The Cylinder And Distal Part Of The Catheter, With Increased Passage And Resistance To Sustainability And Resistance To Stability To In Combination With Flexibility, 80 And 130 Cm Long, Compatible With An Integration Of 5F-7F 5Mm), 12-16Mm), 12-16 Atm., Isolation On Copper Tubes With A Diameter Of At Least 10Mm. Insulation Material Foamed Rubber Form Of Supply Of Material Hollow Pipe Material Class In Thermal Conductivity Low Environmental Safety Of Material Is Safe The Diameter Is Internal: Not Less Than 10 Mm. Oil And Gas Resistance: Good Biological Resistance: Good Smell: Neutral The Temperature Of Use Is From -200 To +105 S. Length Of At Least 20 M., Channel Catheter For Reading. Coaxial Two -Lobed Cylinder Balloon Catheter For Peripheral Angioplasty On The Delivery System (Otw), Compatible With 0.035 “Conductor. Special Material Of The Cylinder Combines Ultra -Thin Walls And Stability To Scratches. Hydrophilic (Lfc) Covering Of The Cylinder And Distal Part Of The Catheter, With Increased Passage And Resistance To Sustainability And Resistance To Stability To In Combination With Flexibility, 80 And 130 Cm Long, Compatible With An Integration Of 5F-7F 5Mm), 12-16Mm), 12-16 Atm., Isolation On Copper Tubes With A Diameter Of At Least 6 Mm. Insulation Material Foamed Rubber Form Of Supply Of Material Hollow Pipe Material Class In Thermal Conductivity Low Environmental Safety Of Material Is Safe The Diameter Is Internal: At Least 6 Mm. Oil And Gas Resistance: Good Biological Resistance: Good Smell: Neutral The Temperature Of Use Is From -200 To +105 S. Length Of At Least 20 M., Bound Cateters For Reading 0.035. Peripheral Cylinder Catheter, A Shipping Coaxial System “Conductor. Stable To Fractures And Crushing, A Delivery System From The Pebax Blend Material. Soft Conical Atravmatic Tip With A Bevel Of 450 For The Best Passage Of Stenosis. The Material Of The Nylon -12 Cylinder, The Gap Pressure Is 20 - 10 Atm, Depending On The Diameter. The Presence Of Two Obli-Contrast Markers At The Edges Of The Cylinder., Diagnostic Microcateter. Microcatometer Is Multifunctional. The Size Of The Flexible Distal Part Of 20 Cm For Atraumatic Conduct In The Vessels. Hydrophilic Coating Of Distal 80Cm. The Presence Of An X -Ray Contrast Platinum Mark, Which Is Encapsulated In The Wall Of The Catheter Located At A Distance Of 1.3 Mm Proximal Than The Distal End Of The Catheter. Three Forms Of The Tip Of The Catheter Are Straight, With A 45 -Degree Bend And Swan Neck. Three Sizes Of Catheter (Proximally/Distally): 2.8F/2.4F. The Length Of The Catheter Is 110 Cm. The Inner Diameter Of The Catheter: 0.020 (0.53Mm) For Catheter 2.8F/2.4F; 0.024 (064Mm). Compatibility From Conductors 0.018 For Catheter 2.8F/2.4F And 0.020. Recommended Conduction Catheter 0.040 (1.02 Mm) For Catheter 2.8F/2.4F. Cabile For Catheter 2.8F/2.4F 3.41 Ml/S For Catheter 110Cm Long, 2.61Ml/S For Catheter 130Cm, 1.71 Ml/S For 150Cm Lengths. Submitted Capacity For Catheter For Catheter 2.8F/2.8F 3.44 Ml/S For Catheter 110Cm, 2.58 Ml/S For Catheter 130Cm, 2.22 Ml/S For Catheter 150Cm Length. Cateters Are 150Cm Catheter Bases: 2.9F -Dark Blue, 2.8Fr - Blue, 2.8F/2.4Fr - Blue., Self -Disclosed Stent System. Nitinol Self -Disclosure Stent. Compatible With 0.035 Conductor. Spiral Arrangement Of Cells. Tantalum Markers At Each End Of The Stent. Open Cells. Not Expanding The Ends Of The Stent. Protection System From Interchangeing The Stent E.X.P.R.T. When Opening. Zero Shortening Of The Stent. All Sizes Of The Stent Are Compatible With 6 Fr Interodista. Profile Stent 0.079. The Length Of The Delivering Catheter Is 120 Cm And 80 Cm. The Manufacturers Guarantee From The Mechanical Fracture To The Installed Stent For At Least 2 Years. The Possibility Of Choosing Stents With Increased Flexibility Or With Increased Radial Strength Of The Size Of The Stent With Increased Flexibility: Diameter - 8; Length: 120 Mm, Stent For Carotid Arteries. A Rapidly Replaced Protection System Against Distal Embolism With A Wicker Nitinol Filter With A Heparin Coating. Independent Rotation Of The Filter On The Wire. The Transverse Profile 3.2Fr. Compatible With Conductors 0.014 Or 0.018. The Length Of The Conductor Is 320Cm With The Possibility Of Shortening Up To 190Cm And The Use Of The Remaining Conductor For Quick Navigation Through The Rx Port. The Platinum Wire At The End Of The Conductor To Provide The Best X -Ray Contract. Golden Wire Of Mounting In The Filter Openings To Determine The Degree Of Opening And Position Of The Filter. The Filter Must Completely Clean The Delivering Catheter During Delivery. When Removing, The Filter Must Completely Clean The 4.2Fr Catheter. The Catheter For Delivery And Removal Is Included In The Kit. Filter Size: 5Mm