GTR 101079024
Bids Are Invited For Defibrillator Acquisition
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
101079024
Tendering Authority
Subscribe to view
Tender No
559/2025
Financer Name
Self-Funded
Work Title
Bids Are Invited For Defibrillator Acquisition
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
10-09-2025
Closed
Work Detail
(Id124794) Defibrillator/Cardioverter, Application: Intended For Adult, Pediatric And Neonatal Patients; Cardioverter/Bifasic, Rectilinea Or Trunched Exponential Defibrillator; Fully Microprocessor, Interact With Cardiac Monitoring, Oxygen Saturation (Spo2) And Transcutaneous Mark Integrated Into A Compact Unit That Operates Independent Of Electric Energy Availability Through Rechargeable Battery; Composed Of: Lcd/Led Mini 6, 5Pol Or Compatible Size For The Presentation Of Three Ecg Channels Simultaneously; Sensitive Screen To The Membrane Touch And/Or Keyboard; Programable Sound And Visual Alarm; It Has Audiovisual Alarms During Continuous Monitoring Of Spo2 And Ecg With Cable (3 And 5 Copies), Ventricular Fibrillation And Maxima And Minimum Cardiac Frequency; Have A Biphasic Waveform With Automatic Adjustment On The Basis Of The Adult Or Pediatric Patient Impedance; Minimum Ip22 Protection Degree; Detection And Viewing On Screen Through Markers Of Most Implantable Mark Pulses; Capture Of The Ecg Signal By The External Pas Or The Patient Cable; Thermal Printer, Which Prints Ecg Curve, Cardiac Frequency, O2 Saturation, Date And Time; It Has Input Of The Isolated Ecg Circuit Of The Electric (Floating) Network And Protection Circuit Against Defibrillation; Defibrillation With System 1, 2, 3; Electrically Isolated Cabinet; Scale For Internal Or External, Adult Or Child Defibrillation, Selectable; Manual Defibrillation With Selectable Scale With Visual Indication; Annul Load Manually; Automatic Discharge Within 2 (Two) Minutes Or Less; Defibrillator Discharge Must Require Simultaneous Activation Of Two Controls (One In Each Pa); Maximo Load Time: Approximately 8S To 200 Joules; It Has Automatic Internal Discharge, When Turned Off; Have Semi -Automatic Defibrillation Mode Or Dea Mode With Text Messages And Voice In Portuguese; Have Autonomy Internal Battery To Minimum 40 Dis
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
006fe86e-7ff3-4eb8-bc4c-48734d461c22.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.