GTR 100828868

Request For Quotation State Purchases For The Purchase Of Equipment

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
100828868
Tendering Authority
Subscribe to view
Tender No
15262642
Financer Name
Self-Funded
Work Title
Request For Quotation State Purchases For The Purchase Of Equipment
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
25-08-2025 Closed
Work Detail
Self-Consuming Liquid-Ring Electric Pumps. Max Submitted 2.4 M3/Hour. Nominal Feed 1.2 M3/H. Ples Mah 31 M. Nominal Pressure 20 M. Power 0.37 Kw. Diameter Vx/Output. Holes 3/4 Inch. . It Is Necessary To Agree On A Sample Of Delivery With The Customer. Unloading And Delivery To The Warehouse At The Expense Of The Supplier., Maximum Pressure, No More (Bar) 10. Maximum Performance (M3/Hour) 9.6. Maximum (M) 8. Length (Mm) 180. Width (Mm) 166. Height (Mm) 147. The Diameter Of The Suction Pipe (Mm) 32. The Diameter Of The Pressure Pipe (Mm) 32. It Is Necessary To Coordinate The Sample Of Delivery With The Customer. Unloading And Delivery To The Warehouse At The Expense Of The Supplier., Ruhrea, Three -Way, Vertical Performance. Building Material - Steel Of The Brand 09G2c At Least 8 Mm Thick, With Heat Treatment Of Seams. Ceramic Inserts Chamber For Additional Fuel Burning. The Boiler Should Have An Audit Hatch With A Heat -Insulating Lid Of Thermal -Resistant Polyamide. Nominal Heat Production: From 800 To To 820 Kws: From 810 To 830 Liters: At Least 4.0 Bar And No More Than 4.2 Bar. Kg. Included Pipe Pipe 3.5 Mm With A Diameter Of 57 Mm., Submissive Sewage Pump With A Capacity Of 4.7 Kw, Complete With A Control And Linen Cable (20M), A Fls Leak Sensor, With A Cabinet Of Automatic Control Of One Pump Based On A Direct Start, Control By Means Of The Emn 10 (3 Pcs). Be Sure To Agree On A Sample Delivery With The Customer. Unloading And Delivery To The Warehouse At The Expense Of The Supplier., A Burner On Light Liquid Fuel, Two -Stage, With Mechanical Spraying Of Fuel. It Is Designed To Burn Light Liquid Fuel (Diesel Oil) In Industrial Boilers To Ensure Effective And Safe Heating Of The Coolant. The Thermal Power Range Is 1581–4162 Kw. Fuel Consumption 125–358 Kg/H. Three -Phase Variable Voltage, Three -Phase Variable Voltage 380 Hz. Ip40. Air Air Flow For Each Regime. The Possibility Of Servicing The Spraying Unit Without Dismantling The Burner From The Boiler. A Universal Flange With A Sealing Ring Suitable For Various Types Of Boilers. A Sliding Flange For The Exact Installation Of The Burner In The Boiler. Double Explosive Deflector And Flame Disk. A Three -Phase Electric Motor For A Fan And Fuel Pump. Be Sure To Agree On A Sample Delivery With The Customer. Unloading And Delivery To The Warehouse At The Expense Of The Supplier., The Pump For The Burner E 7 Na 1001 5P. Vid Of The Pumped Liquid: Diesel Fuel. Pump Series: E: Pressure Adjustment. Type Of Model: Without An Electromagnetic Valve. The Pressure Range On The Nozzle: From 14 To 30 Bar. Installation Method: Flange ∅ 54 Mm. Direction Of The Shaft Rotation (From The Shaft Side): A: Rotation Clockwise / Nozzle On The Right. Exit To The Nozzle: ¼ Inch - 6.35 Mm. Productivity At A Pressure Of 20 Bar 355 L/H. The Suction And Reverse Line: ½ Inch - 12.7 Mm. Val Design: One Cavity. Manometer Port: ⅛ Inch - 3.175 Mm. Vacuummeter Port: ½ Inch - 12.7 Mm. Valve Function: Pressure Adjustment And Locking. Mesh Filter: Open Region: 45 Cm². Mesh Filter: Hole Size: 550 Μm. Val Diameter: 11 Mm. Bypas Plug: Installed In The Reverse Line For The Two-Pipe System And Is Removed With A Size Key Size. Factory Pressure Installations: 20 Bar. Operational Viscosity: From 3 To 75 Mm²/S. Fuel Temperature: From 0 To +90 ºc Max. In The Pump. Pressure At The Entrance: 1.5 Bar. Output Pressure: 1.5 Bar. Highness Height: Max. 0.45 Bar Of A Vacuum To Prevent Air Separation From Fuel. Nominal Rotation Speed: 2850 Rpm. Maximum Rotation Speed: 3600 Rpm. The Torque: 0.3 N · M. It Is Necessary To Agree On A Sample Of Delivery With The Customer. Unloading And Delivery To The Warehouse At The Expense Of The Supplier., The Type Of Surface Pump Is Circulating. The Installation Of The Pump Is Vertical. Water Quality Is Clean. Passing Capacity 10.2 Cubic Meters. M/H. Power Consumption 0.38 Kw. The Maximum Pressure Is 11 M. The Voltage From The Network Of 400 V. The Installation Length Of The Circulation Pump Is 180 Mm. The Diameter Of The Thread Of The Outgoing Hole (G) 2. The Type Of Rotor Is Wet. Be Sure To Agree On A Sample Delivery With The Customer. Unloading And Delivery To The Warehouse At The Expense Of The Supplier., Centrifugal Pump. Type Of Water Pump Is Surface. Material Of The Cast Iron. The Material Of The Working Wheel Ppe/Ps-Gf30. The Color Is Green. Cumed Current Of 4.5 A. The Purpose For Water Supply. The Centrifugal Pump Is 2.2 Kw. The Voltage From The Network Is 400 V. The Installation Length Of The Circulation Pump Is 320 Mm. The Maximum Operating Pressure Is 10 Bar. The Number Of Steps 1. The Diameter Of The 40 Mm. The Number Of Phases Is 3.3. It Is Necessary To Agree On A Sample Of Delivery With The Customer. Unloading And Delivery To The Warehouse At The Expense Of The Supplier., The Type Of Water Pump Is Superficial. The Type Of Surface Pump Is Circulating. The Installation Of The Pump Is Vertical. Water Quality Is Clean. Passing 31 Cubic Meter. M/H. Power Consumption 0.82 Kw. The Maximum Pressure Is 10 M. Voltage From The Network 230 V. The Installation Length Of The Circulation Pump Is 280 Mm. Before Delivery, It Is Imperative To Agree On A Sample Delivery With The Customer. Unloading And Delivery To The Warehouse At The Expense Of The Supplier.
Key Value
Tender Value
24,972,484 - KZT
Tender Documents
Global Tender Document
17182bc9-8fd5-42cb-9623-f12384babded.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders