1 With Its Registered Office: Ul. Piłsudskiego 18, 72-300 Gryfice, 4) Poviat Center For Geodetic And Cartographic Documentation In Gryfice With Headquarters: Ul. Koszarowa 4, 72-300 Gryfice, 5) Poviat Family Support Center In Gryfice With Headquarters: Ul. Koszarowa 4, 72-300 Gryfice, 6) Poviat Labor Office In Gryfice With Headquarters: Ul. Koszarowa 4, 72-300 Gryfice, 7) High School With Bilingual Departments Bolesława Chrobrego With Headquarters Ul. Wałowa 18, 72-300 Gryfice, 8) School Complex Czesława Miłosz In Gryfice With Headquarters: Ul. 11 November 10, 72-300 Gryfice, 9) School Complex Wincenty Witos In Płoty With Headquarters: Ul. Paderewskiego 13, 72-310 Płoty, 10) Complex Of Upper Secondary Schools Zbigniew Herbert In Trzebiatów With Headquarters: Ul. Plac Lipowy 15, 72-320 Trzebiatów, 11) Youth Educational Center Janusz Korczak In Rewal With Its Registered Office: Ul. Klifowa 17, 72-344 Rewal, 12) Youth Sociotherapy Center In Waniorów With Headquarters: 72-312 Waniora 4:13) Care And Educational Institution, Childrens House In Gryfice With Headquarters: Ul. Polna 8 And Trzygłowska 30, 72-300 Gryfice, 14) Psychological And Pedagogical Counseling Center In Gryfice With Headquarters: Ul. Polna 8, 72-300 Gryfice, 15) Nursing Home In Gryfice With Headquarters: Ul. Kościuszki 35 And 71, 72-300 Gryfice, 16) Nursing Home In Jaromin With Headquarters: Jaromin 50, 72-320 Trzebiatów, 17) Poviat Support Center In Gryfice With Headquarters: Ul. Koszarowa 1, 72-300 Gryfice. 2. The Aggregate Is To Ensure The Power Supply Of The Most Important Systems (Including Lighting, It, Server Room, Security Systems) In The Event Of Power Failure From The Power Grid. 3. The Order Also Includes The Delivery Of A Complete Set Of Connection Cables (For Power Supply And External Devices), Technical Documentation And Conducting Necessary Training. 4. Technical Requirements Regarding The Power Generator: 1) Aggregate Power And Parameters: A) Rated Power: Minimum 80 Kw Meeting The Stage5 Emission Standard; B) The Contracting Authority Reserves The Right To Increase The Power During The Implementation Procedure Based On The Analysis Of The Buildings Energy Demand (Before Delivery); C) Output Voltage: 400/230 V, 50 Hz, 50 Hz, 50 Hz, 50 Hz, Three -Phase; D) Degree Of Generator Protection: In Accordance With The Standard Of Operation Of The Device Outside In Difficult Atmospheric Conditions; E) Insulation Class: H.2) Engine: A) Diesel (Diesel), Liquid -Cooled; B) Starting Power Supply: 12V Or 24V Dc; C) Fuel Reservoir Capacity: Ensuring A Minimum Of 8 Hours Of Operation At 75% Load; D) Engine Protection: Low Oil Pressure High Temperature Of The Cooling Liquid, Battery Charging Failure, Overload, Start -Up Failure. 3) Generator: A) Brushless, Self -Insulated, Synchronous; B) Equipped With An Electronic Avr Voltage Regulator; C) Adapted To Work With Devices Sensitive To Voltage Quality (E.G. It, Server). Aggregate; B) Reading Parameters: Voltage, Frequency, Electricity, Powe