The Counter For Two- Or Three-Led Accounting Of Active And Reactive Electric Energy. Accuracy Class (Asset/Reactive) - Transformer Inclusion 0.2S/0.5; 0.5S/1.0 - Direct Inclusion Of 1.0/2.0. Nominal Voltage, In Transformer Inclusion Through Tt And Tt: 3*57.7/100, Direct Inclusion: 3*230/400. The Established Range Of Operating Voltages, B: 207 ... 253 (At Uno = 230), An Expanded Operating Range Of Voltages, B: 184 ... 264, The Maximum Working Range Of Voltages, B: 0 ... 264, Nominal (Maximum) Current, A - Transformer Inclusion: 5 (10), - Direct Inclusion: 5 (60); 5 (100) Network Frequency, Hz - 49 ... 51, Maximum Current For Transformer Inclusion Counters Within 0.5 Seconds, A - For Imax = 10A: 40,200 The Maximum Current For Counter -Inclusion Meters For 10 Msecks, And For Imax = 60A: 1800, Starting Current (Sensitivity), And For Ino (Max) = 5 (10) A,,,,,,,,,, Of The Inu Uno = 57.7 Or 230B: 0.005, - For Ino (Max) = 5 (60) A, Unu = 230B: 0.020, For Ino (Max) = 5 (100) A, Unu = 230B: 0.020 Active / Complete Power Consumption Of Each Parallel Meter Chain, Wt - For Uno = 57.7: 1.0 / 2.0 - For Uno = 230: 1.0/9.0 Additional Complete Meter Power Consumption With The Plc-Ii Interface Installed By The Plc-Ii Interface, 1.5/24 Additional Consumed Meter Capacity With The Gsm/Rs485 Interface Module No More, Vt/Vt/Vt/5 Voltage Of External Reserve Power (For Modifications With Litera P),, 4/5). Q: +12 B. Complete Power Consumed By A Current Circuit Is No More, In*A: 0.3 Number Of Tariffs: 1 ... 4. The Number Of Tariff Seasons (Months): 12. The Accuracy Of The Course Of Hours At T = 20 ± 5 ° C, S/Day: ± 0.5. The Depth Of Storage Of 30 -Mines Of Energy Sections, Day: 170. The Depth Of Storage Of Daily Sections Of Energy, Day: 120. The Depth Of Storage Of Monthly Energy Sections, Months: 36. The Number Of Galvanically Unleashed Impulse Outputs: - Telemetric: 1, - The Control Control Programmable: 1.