Bids Are Invited For Acquisition Of A Digital Radiological Ensemble, Intended For Complementary Health And Primary Care Of The Municipality Of Morretes, According To Proposal No. 11938311000123032/Ms.
Bids Are Invited For Acquisition Of A Digital Radiological Ensemble, Intended For Complementary Health And Primary Care Of The Municipality Of Morretes, According To Proposal No. 11938311000123032/Ms.
Digital Radiological Assembly Composed Of High Frequency X-Ray Generating System, Microprocessor, With A Minimum Power Of 52 Kw Or Higher, 220V Or 380V Three-Phase Voltage, With Autotransformer Supply When Necessary, Adjustable Voltage Range Of 40 To 150 Kv In 1 Kv Increments, 10 To 500 Ma Or Higher, 1 To 640 Or Higher Time. 5 Ms Or Lower Exposure Up To At Least 5 Seconds. The Equipment Should Have Automatic Exposure Control (Aec), Dap Calculation And Indication Software According To Iec Standard, Anatomical Organs Program With At Least 200 Pre-Programmed Techniques, Pipe Thermal Protection And Multicolored Lcd Display For Parameter Visualization. The Generator Must Be Installed Under The Table, And The Operating Command Must Allow The Selection Of All The Parameters Mentioned. You Must Track Specific Force Frame And Pair Of High Voltage Cables. The X-Ray Tube Must Have A Rotating Annode With A Minimum Rotation Of 9,000 Rpm, At Least 300 Khu Thermal Capacity, A Fine Focus Of A Maximum Of 0, 6 Mm And A Thick Focus Of A Maximum Of 1, 2 Mm. The Stone-Holder Stative Should Be Of The Ground Floor Type, With A Minimum Vertical Movement Of 140 Cm, Minimum Longitudinal Displacement Of 260 Cm, ± 90 ° Tub-Tube Arm Rotation With Electromagnetic Brakes. The Table Must Have A Radiotransparent Floating Top, With Longitudinal And Transverse Movements, Minimum Dimensions Of 200 Cm X 80 Cm, Fixed Anti -Addust Grid With At Least 40 Lines Per Centimeter, 100 To 180 Cm Variable Focus, Minimum Load Capacity Of 200 Kg And Electromagnetic Brakes For The Movements. Bucky Mural Must Have A Minimum Vertical Displacement Of 135 Cm, Printed Centralization Cross, Variable Focus From 100 To 180 Cm And Mechanical Or Electromagnetic Brake System. The Collimator Should Be A Light Manual With Adjustable Field, Electronic Drive By Timer And Led Lamp. The Digital Detector D
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.